- About Badfish
- Scope
- Features
- Requirements
- Setup
- Usage
- Common Operations
- Enforcing an OpenStack Director-style interface order
- Enforcing a Foreman-style interface order
- Enforcing a Custom interface order
- Forcing a one time boot to a specific device
- Forcing a one time boot to a specific mac address
- Forcing a one time boot to a specific type
- Forcing a one-time boot to PXE
- Rebooting a System
- Power Cycling a System
- Power State Control
- Check Power State
- Get Power Consumed
- Resetting iDRAC
- Resetting BMC
- BIOS factory reset
- Check current boot order
- Toggle boot device
- Variable number of retries
- Firmware inventory
- Delta of firmware inventories
- Clear Job Queue
- List Job Queue
- Check Job Status
- Set Bios Password
- Remove Bios Password
- List Network Interfaces
- List Memory
- List Processors
- List Serial Number or Service Tag
- Check Virtual Media
- Mount Virtual Media
- Unmount Virtual Media
- Boot to Virtual Media
- Check Remote Image
- Boot to Remote Image
- Detach Remote Image
- Get SRIOV mode
- Set SRIOV mode
- Get BIOS attributes
- Get specific BIOS attribute
- Set BIOS attribute
- Change between BIOS and UEFI modes
- Get server screenshot
- Targets for server configuration profile
- Export server configuration profile
- Import server configuration profile
- Bulk actions via text file with list of hosts
- Verbose Output
- Log to File
- Formatted output
- iDRAC and Data Format
- Contributing
- Contact
Badfish is a Redfish-based API tool for managing bare-metal systems via the Redfish API
You can read more about badfish at the QUADS website.
Right now Badfish is focused on managing Dell, SuperMicro and HPE systems, but can potentially work with any system that supports the Redfish API. Functionality may vary depending on the vendor Redfish implementation with Dell systems having the most functionality.
We're mostly concentrated on programmatically enforcing interface/device boot order to accommodate TripleO based OpenStack and OpenShift deployments while simultaneously allowing easy management and provisioning of those same systems via The Foreman. Badfish can be useful as a general standalone, unified vendor IPMI/OOB tool however as support for more vendors is added.
- Toggle and save a persistent interface/device boot order on remote system
- Support for BIOS and EFI modes for interface/device boot operations
- Perform one-time boot to a specific interface, mac address or device listed for PXE booting
- Enforce a custom interface boot order
- Check current boot order
- Display current power consumption in watts
- Reboot host
- Reset iDRAC
- View, check and clear iDRAC jobs
- Revert to factory settings
- Check/set SRIOV
- Take a remote screenshot of server KVM console activity (Dell only).
- Support tokenized authentication
- Check and set BIOS attributes (e.g. setting UEFI or BIOS mode)
- Get firmware inventory of installed devices supported by iDRAC
- Check/ummount virtual media en-masse across a set of systems (SuperMicro only)
- Obtain limited hardware information (CPU, Memory, Interfaces)
- Bulk actions via plain text file with list of hosts for parallel execution
- Logging to a specific path
- Containerized Badfish image
- (Dell) iDRAC7,8,9 or newer
- (Dell) Firmware version
2.60.60.60
or higher - Any Redfish IPMI 2.0 support on non-Dell systems
- iDRAC administrative account
- Python >=
3.8
or podman as a container. - python3-devel >=
3.8
(If using standalone or RPM package below).
dnf copr enable quadsdev/python3-badfish -y
dnf install python3-badfish -y
Active releases:
- CentOS Stream 8 and 9
- Rocky & Alma Linux 8 and 9
- EPEL 8 and 9
- All current Fedora releases
- Some older Fedora releases, check the RPM releases here
git clone https://github.com/redhat-performance/badfish && cd badfish
python3 -m pip install --upgrade build
python3 -m build
python3 -m pip install dist/badfish-1.0.2.tar.gz
NOTE:
- This will allow Badfish to be called from the terminal via the
badfish
command - This requires
python3-devel
if you see errors about missingPython.h
.
Perhaps the easiest way to run Badfish is with Podman, you can see more usage details below on using the Badfish container with Podman. You can substitute Docker for Podman as well though not all functionality may be actively tested as we prefer Podman.
podman pull quay.io/quads/badfish
Badfish can be consumed in several ways after successful installation. Either via the standalone cli tool or as a python library. For an extensive use of the cli tool check the Common Operations section of this file.
NOTE: Badfish operates optionally against a YAML configuration file to toggle between key:value pair sets of boot interface/device strings. You just need to create your own interface config that matches your needs to easily swap/save interface/device boot ordering or select one-time boot devices.
If Badfish has been properly installed in the system (RPM package install, setuptools), then the library should be available under your python path therefore it can be imported as a python library to your python project.
from badfish.main import badfish_factory
badfish = await badfish_factory(
_host=_oob_mgmt,
_username=_username,
_password=_password,
)
await badfish.get_boot_devices()
success = await badfish.boot_to(badfish.boot_devices[0]['Name'])
if success:
print("Change boot device success")
result = await badfish.reboot_server()
if not result:
print("Failed to reboot system")
NOTE: Badfish relies heavily on asyncio for executing multiple tasks. If you will be using badfish from outside an async function you will have to provide an async event loop and run via run_until_complete
Badfish happily runs in a container image using Podman or Docker (likely, but not actively tested).
podman pull quay.io/quads/badfish
podman run -it --rm --dns $DNS_IP quay.io/quads/badfish -H $HOST -u $USER -p $PASS --reboot-only
NOTE:
- If you are running Badfish against a host inside a VPN to an address without public resolution you must specify your VPN DNS server ip address with
--dns
- If you would like to use a different file for
config/idrac_interfaces.yml
you can map a volume to your modified config with-v idrac_interfaces.yml:config/idrac_interfaces.yml:Z
- If you want to run any actions that would have output files like
--screenshot
you can map the container root volume to a directory on your local machine where you would like to have those files stored like-v /tmp/screens:/badfish:Z
- When mapping a volume to a container make sure to use the
:Z
suffix for appropiate labeling
Virtualenv is a wonderful tool to sandbox running Python applications or to separate Python versions of components from your main system libaries. Unfortunately it can be problematic with running Badfish directly from the Git repo inside a virtualenv sandbox.
While we strongly recommend using the podman method of calling Badfish inside a virtual environment you can still do it directly from the repository via virtualenv but you would need to prepend the call to Badfish with the setting of the PYTHONPATH
environment variable pointing at the path of your Badfish repository.
virtualenv venv
source venv/bin/activate
pip install --upgrade pip
pip install -r requirements.txt
PYTHONPATH={BADFISH_REPO_PATH} python3 src/badfish/main.py -h
We will likely add more libaries in the future and can't guarantee these will be visible within your virtualenv without more symlinks or workarounds.
If you choose to install Badfish via RPM package then it'll be located in /usr/bin/badfish
and you don't need to do much else beyond know the correct command syntax for your required operations.
Note: If you plan on using the idrac_interfaces.yml
file to further customize or define pre-made boot orders you'll want to model your own based on the repo example file. This file serves as an example but is specific to our internal environments so you'd most likely want to modify it to match your environment and naming conventions.
You can always retrieve our example idrac_interfaces.yml
file via:
curl https://raw.githubusercontent.com/redhat-performance/badfish/master/config/idrac_interfaces.yml --output idrac_interfaces.yml
In our performance/scale R&D environments TripleO-based OpenStack deployments require a specific 10/25/40GbE NIC to be the primary boot device for PXE, followed by disk, and then followed by the rest of the interfaces.
badfish -H mgmt-your-server.example.com -u root -p yourpass -i config/idrac_interfaces.yml -t director
Foreman and Red Hat Satellite (as of 6.x based on Foreman) require managed systems to first always PXE from the interface that is Foreman-managed (DHCP/PXE). If the system is not set to build it will simply boot to local disk. In our setup we utilize a specific NIC for this interface based on system type.
badfish -H mgmt-your-server.example.com -u root -p yourpass -i config/idrac_interfaces.yml -t foreman
Badfish allows you to supply your own interface order type in addition to director
and foreman
modes as defined in idrac_interfaces.yml
- Supply your own distinct string in the first part of the key value (split by
_
) - Refer to it via the string name
- Consequently host type overrides can also be leveraged
We will use the custom interface order called ocp5beta as an example.
Example any system you want to boot with a certain custom interface order.
ocp5beta_fc640_interfaces: NIC.Slot.2-4,NIC.Slot.2-1,NIC.Slot.2-2,NIC.Slot.2-3
Example a rack of systems you want to boot with a certain custom interface order.
ocp5beta_f21_fc640_interfaces: NIC.Slot.2-4,NIC.Slot.2-1,NIC.Slot.2-2,NIC.Slot.2-3
Example a specific system you want to boot with a certain custom interface order
ocp5beta_f21_h23_fc640_interfaces: NIC.Slot.2-4,NIC.Slot.2-1,NIC.Slot.2-2,NIC.Slot.2-3
Now you can run Badfish against the custom interface order type you have defined, refer to the custom overrides on further usage examples.
src/main.py --host-list /tmp/hosts -u root -p password -i config/idrac_interfaces.yml -t ocp5beta
To force systems to perform a one-time boot to a specific device on the next subsequent reboot you can use the --boot-to
option and pass as an argument the device you want the one-time boot to be set to. This will change the one time boot BIOS attributes OneTimeBootMode and OneTimeBootSeqDev and on the next reboot it will attempt to PXE boot or boot from that interface string. You can obtain the device list via the --check-boot
directive below.
badfish -H mgmt-your-server.example.com -u root -p yourpass --boot-to NIC.Integrated.1-3-1
To force systems to perform a one-time boot to a specific mac address on the next subsequent reboot you can use the --boot-to-mac
option and pass as an argument the device mac address for a specific NIC that you want the one-time boot to be set to. This will change the one time boot BIOS attributes OneTimeBootMode and OneTimeBootSeqDev and on the next reboot it will attempt to PXE boot or boot from that interface.
badfish -H mgmt-your-server.example.com -u root -p yourpass --boot-to-mac A9:BB:4B:50:CA:54
To force systems to perform a one-time boot to a specific type on the next subsequent reboot you can use the --boot-to-type
option and pass as an argument the device type, as defined on the iDRAC interfaces yaml, that you want the one-time boot to be set to. For this action you must also include the path to your interfaces yaml. This will change the one time boot BIOS attributes OneTimeBootMode and OneTimeBootSeqDev and on the next reboot it will attempt to PXE boot or boot from the first interface defined for that host type on the interfaces yaml file.
badfish -H mgmt-your-server.example.com -u root -p yourpass -i config/idrac_interfaces.yml --boot-to-type foreman
Note --boot-to
, --boot-to-type
, and --boot-to-mac
require you to manually perform a reboot action, these simply just batch what the system will boot to on the next boot. For this you can use either --power-cycle
or --reboot-only
.
To force systems to perform a one-time boot to PXE, simply pass the --pxe
flag to any of the commands above, by default it will pxe off the first available device for PXE booting. This is equivalent to the ipmitool command chassis bootdev pxe options=persistent
and should be used with SuperMicro/HPE systems or non-Dell systems that support a minimal IPMI 2.0 specification.
For Dell systems please use either --boot-to
, --boot-to-mac
or --boot-to-type
for temporary PXE to a specific interface or change the boot order permanently to achieve your desired effect.
badfish -H mgmt-your-server.example.com -u root -p yourpass -i config/idrac_interfaces.yml --pxe
In certain cases you might need to only reboot the host, for this case we included the --reboot-only
flag which will force a GracefulRestart on the target host. Note that this option is not to be used with any other option.
badfish -H mgmt-your-server.example.com -u root -p yourpass --reboot-only
For a hard reset you can use --power-cycle
flag which will run a ForceOff instruction on the target host. Note that this option is not to be used with any other option.
badfish -H mgmt-your-server.example.com -u root -p yourpass --power-cycle
You can also turn a server on or off by using options --power-on
and --power-off
respectively.
badfish -H mgmt-your-server.example.com -u root -p yourpass --power-on
For checking the current power state of a server you can run badfish with the --power-state
option.
badfish -H mgmt-your-server.example.com -u root -p yourpass --power-state
Partial Output:
- INFO - Power state for mgmt-your-server.example.com: On
This displays the current power usage for Dell / Supermicro server(s).
badfish -H mgmt-your-server.example.com -u root -p --get-power-consumed
Partial Output:
- INFO - Current watts consumed: 213
For the replacement of racadm racreset
, the optional argument --racreset
was added. When this argument is passed to badfish
, a graceful restart is triggered on the iDRAC itself.
badfish -H mgmt-your-server.example.com -u root -p yourpass --racreset
NOTE:
- Dell specific command, for Supermicro servers there is an equivalent of
--bmc-reset
For the replacement of ipmitool bmc reset
or ipmiutil reset
, the optional argument --bmc-reset
was added. When this argument is passed to badfish
, a graceful restart is triggered on the BMC itself.
badfish -H mgmt-your-server.example.com -u root -p yourpass --bmc-reset
NOTE:
- Supermicro specific command, for Dell servers there is an equivalent of
--racreset
You can restore BIOS default settings by calling Badfish with the option --factory-reset
.
badfish -H mgmt-your-server.example.com -u root -p yourpass --factory-reset
NOTE:
- WARNING: Use this carefully, vendor defaults differ and may be disruptive. Do not use this in the Scale Lab or ALIAS.
To check the current boot order of a specific host you can use the --check-boot
option which will return an ordered list of boot devices. Additionally you can pass the -i
option which will in turn print on screen what type of host does the current boot order match as those defined on the iDRAC interfaces yaml.
badfish -H mgmt-your-server.example.com -u root -p yourpass -i config/idrac_interfaces.yml --check-boot
If you would like to enable or disable a boot device you can use --toggle-boot-device
argument which takes the device name as input and will toggle the Enabled
state from True to False and vice versa.
badfish -H mgmt-your-server.example.com -u root -p yourpass --toggle-boot-device NIC.Integrated.1-3-1```
At certain points during the execution of badfish
the program might come across a non responsive resources and will automatically retry to establish connection. We have included a default value of 15 retries after failed attempts but this can be customized via the --retries
optional argument which takes as input an integer with the number of desired retries.
badfish -H mgmt-your-server.example.com -u root -p yourpass -i config/idrac_interfaces.yml -t foreman --retries 20
If you would like to get a detailed list of all the devices supported by iDRAC you can run badfish
with the --firware-inventory
option which will return a list of devices with additional device info.
badfish -H mgmt-your-server.example.com -u root -p yourpass --firmware-inventory
If you would like to get a delta between firmware inventories of two servers, you can do so with the --delta
option. This option takes a second host address as its argument. Only the firmware that's on both servers and has different versions will get displayed.
badfish -H mgmt-your-server.example.com -u root -p yourpass --firmware-inventory --delta mgmt-your-other-server.example.com
If you would like to clear all the jobs that are queued on the remote iDRAC you can run badfish
with the --clear-jobs
option which query for all active jobs in the iDRAC queue and will post a request to clear the queue.
badfish -H mgmt-your-server.example.com -u root -p yourpass --clear-jobs
You can also force the clearing of Dell iDRAC job queues by passing the --force
option.
badfish -H mgmt-your-server.example.com -u root -p yourpass --clear-jobs --force
If you would like to list all active jobs that are queued on the remote iDRAC you can run badfish
with the --ls-jobs
option which query for all active jobs in the iDRAC queue and will return a list with all active items.
badfish -H mgmt-your-server.example.com -u root -p yourpass --ls-jobs
If you would like to the status of an existing LifeCycle controller job you can run badfish
with the --check-job
option and passing the job id which can be obtained via --ls-jobs
. This will return a detail of the specific job with status and percentage of completion.
badfish -H mgmt-your-server.example.com -u root -p yourpass --check-job JID_340568202796
If you would like to set the bios password you can run badfish
with the --set-bios-password
option and passing the new password with --new-password
. If a password is already set you must pass this with --old-password
otherwise optional.
badfish -H mgmt-your-server.example.com -u root -p yourpass --set-bios-password --new-password new_pass --old-password old_pass
If you would like to remove the bios password you can run badfish
with the --remove-bios-password
option and passing the existing password with --old-password
.
badfish -H mgmt-your-server.example.com -u root -p yourpass --remove-bios-password --old-password old_pass
For getting a list of network interfaces with individual metadata for each you can run badfish
with the --ls-interfaces
option.
badfish -H mgmt-your-server.example.com -u root -p yourpass --ls-interfaces
For getting a detailed list of memory devices you can run badfish
with the --ls-memory
option.
badfish -H mgmt-your-server.example.com -u root -p yourpass --ls-memory
For getting a detailed list of processors you can run badfish
with the --ls-processors
option.
badfish -H mgmt-your-server.example.com -u root -p yourpass --ls-processors
For getting the system's serial number or on Dell servers the service tag (equivalent to racadm getsvctag
) you can run badfish
with the --ls-serial
option.
badfish -H mgmt-your-server.example.com -u root -p yourpass --ls-serial
If you would like to check for any active virtual media you can run badfish
with the --check-virtual-media
option which query for all active virtual devices.
badfish -H mgmt-your-server.example.com -u root -p yourpass --check-virtual-media
If you would like to mount an ISO from network you can run badfish
with the --mount-virtual-media
option which post a request for mounting the ISO virtual media (Virtual CD). Full address to the ISO is needed as an argument.
badfish -H mgmt-your-server.example.com -u root -p yourpass --mount-virtual-media http://storage.example.com/folder/linux.iso
If you would like to unmount all active virtual media you can run badfish
with the --unmount-virtual-media
option which post a request for unmounting all active virtual devices.
badfish -H mgmt-your-server.example.com -u root -p yourpass --unmount-virtual-media
If you would like to boot to virtual media (Virtual CD) you can run badfish
with the --boot-to-virtual-media
option which sets the onetime next boot device to virtual CD.
badfish -H mgmt-your-server.example.com -u root -p yourpass --boot-to-virtual-media
If you would like to check the attach status of a remote ISO in DellOSDeployment service you can run badfish
with the --check-remote-image
option.
badfish -H mgmt-your-server.example.com -u root -p yourpass --check-remote-image
NOTE:
- This is only supported on DELL devices.
If you would like to boot to a remote ISO on NFS with DellOSDeployment service you can run badfish
with the --boot-remote-image
option which will attach the image and reboot the server to it. Expects the NFS path to the ISO as the argument.
badfish -H mgmt-your-server.example.com -u root -p yourpass --boot-remote-image nfs-storage.example.com:/mnt/folder/linux.iso
NOTE:
- This is only supported on DELL devices.
If you would like to detach an ISO from DellOSDeployment service you can run badfish
with the --detach-remote-image
option.
badfish -H mgmt-your-server.example.com -u root -p yourpass --detach-remote-image
NOTE:
- This is only supported on DELL devices.
For checking if the global SRIOV mode is enabled you can use --get-sriov
badfish -H mgmt-your-server.example.com -u root -p yourpass --get-sriov
NOTE:
- This is only supported on DELL devices.
For changing the mode of the SRIOV glabal BIOS attribute, we have included 2 new arguments.
In case the setting is in disabled mode, you can enable it by passing --enable-sriov
badfish -H mgmt-your-server.example.com -u root -p yourpass --enable-sriov
On the contrary, if you would like to disable the SRIOV mode, you can now pass --disable-sriov
badfish -H mgmt-your-server.example.com -u root -p yourpass --disable-sriov
NOTE:
- This is only supported on DELL devices.
To get a list of all FQDDs for all NICs on the server you can run badfish with --get-nic-fqdds
.
badfish -H mgmt-your-server.example.com -u root -p yourpass --get-nic-fqdds
To get a list of all NIC attributes we can potentially modify (some might be set as read-only), you can run badfish with --get-nic-attribute
passing the desired FQDD and this will return a list off all NIC attributes with their current value set.
badfish -H mgmt-your-server.example.com -u root -p yourpass --get-nic-attribute NIC.Integrated.1-1-1
To change the value of a NIC attribute you can use --set-nic-attribute
with the desired FQDD, passing both --attribute
and desired --value
.
badfish -H mgmt-your-server.example.com -u root -p yourpass --set-nic-attribute NIC.Integrated.1-1-1 --attribute LegacyBootProto --value PXE
NOTE:
- This action will trigger a reboot of the server to apply the changes. Changes will be reflected after the reboot is completed.
To get a list of all BIOS attributes we can potentially modify (some might be set as read-only), you can run badfish with --get-bios-attribute
alone and this will return a list off all BIOS attributes with their current value set.
badfish -H mgmt-your-server.example.com -u root -p yourpass --get-bios-attribute
In case you would like to get a more detailed view on the parameters for a BIOS attribute you can run --get-bios-attribute
including the specific name of the attribute via --attribute
.
badfish -H mgmt-your-server.example.com -u root -p yourpass --get-bios-attribute --attribute ProcC1E
To change the value of a bios attribute you can use --set-bios-attribute
passing both --attribute
and --value
.
badfish -H mgmt-your-server.example.com -u root -p yourpass --set-bios-attribute --attribute ProcC1E --value Enabled
NOTE:
- You can get the list of allowed values you can pass for that attribute by looking at the attribute details via
--get-bios-attribute
for that specific one.
- Building on the get/set bios attribute commands above here's how you can manage BIOS and UEFI modes on supported servers.
NOTE:
- This is only supported on Dell devices.
- First determine what bootmode state your server is using before proceeding.
badfish -H mgmt-your-server.example.com -u root -p yourpass --get-bios-attribute --attribute BootMode
badfish -H mgmt-your-server.example.com -u root -p yourpass --set-bios-attribute --attribute BootMode --value Uefi
badfish -H mgmt-your-server.example.com -u root -p yourpass --set-bios-attribute --attribute BootMode --value Bios
NOTE:
- Like all batch-driven actions this takes a reboot and time to process so be patient.
- You should also give it time to process before checking result via
--get-bios-attribute --attribute BootMode
as it could be cached for a minute or two after processing.
If you would like to get a screenshot with the current state of the server you can now run badfish with --screenshot
which will capture this and store it in the current directory in png format.
badfish -H mgmt-your-server.example.com -u root -p yourpass --screenshot
If you want to get a list of allowed targets for SCP export or import you can get that with the --get-scp-targets
command, takes either Export
or Import
as an argument.
badfish -H mgmt-your-server.example.com -u root -p yourpass --get-scp-targets (Export | Import)
NOTE:
- This is only supported on Dell devices.
If you would like to export a SCP as a JSON file for either some specific targets or all of them, you can run badfish with --export-scp
and specify a path where the config should be saved to with its argument. Targets can be specified with --scp-targets
flag that takes a comma separated list of targets as an argument. Read only arguments can be included with the --scp-include-read-only
flag.
badfish -H mgmt-your-server.example.com -u root -p yourpass --export-scp "./" --scp-targets IDRAC,BIOS --scp-include-read-only
NOTE:
- This is only supported on Dell devices.
If you would like to import a SCP in a JSON file for either some specific targets or all of them, you can run badfish with --import-scp
. Targets can be specified with --scp-targets
flag that takes a comma separated list of targets as an argument. Command will reboot the server and return it to a state at the launch start of import.
badfish -H mgmt-your-server.example.com -u root -p yourpass --import-scp "./example_export.json" --scp-targets IDRAC,BIOS
NOTE:
- This is only supported on Dell devices.
In the case you would like to execute a common badfish action on a list of hosts, you can pass the optional argument --host-list
in place of -H
with the path to a text file with the hosts you would like to action upon and any addtional arguments defining a common action for all these hosts.
badfish --host-list /tmp/bad-hosts -u root -p yourpass --clear-jobs
If you would like to see a more detailed output on console you can use the --verbose
option and get a additional debug logs. Note: this is the default log level for the --log
argument.
badfish -H mgmt-your-server.example.com -u root -p yourpass -i config/idrac_interfaces.yml -t foreman --verbose
If you would like to log the output of badfish
you can use the --log
option and pass the path to where you want badfish
to log it's output to.
badfish -H mgmt-your-server.example.com -u root -p yourpass -i config/idrac_interfaces.yml -t foreman --log /tmp/bad.log
If you would like to easier query some information listed by badfish, you can tell badfish to output in either JSON or YAML. Formatted output is also supported for bulk actions with --host-list
. Supported commands that list some information are:
--ls-*
--firmware-inventory
--get-bios-attribute
(also works with specified attribute by--attribute
after)--check-boot
--check-virtual-media
--power-state
.
badfish -H mgmt-your-server.example.com -u root -p yourpass --output json/yaml --firmware-inventory
Your usage may vary, this is what our configuration looks like via config/idrac_interfaces.yml
- Note that these are BIOS mode, EFI interfaces may be different and not yet recorded everywhere for our uses.
Machine Type | Network Interface |
---|---|
Dell fc640 | NIC.Integrated.1-1-1 |
Dell r620 | NIC.Integrated.1-3-1 |
Dell r630 | NIC.Slot.2-1-1 |
Dell r930 | NIC.Integrated.1-3-1 |
Dell r720xd | NIC.Integrated.1-3-1 |
Dell r730xd | NIC.Integrated.1-3-1 |
Dell r740xd | NIC.Integrated.1-3-1 |
Dell r640 | NIC.Integrated.1-1-1 |
Dell r650 | NIC.Integrated.1-1-1 |
Dell r660 | NIC.PxeDevice.1-1 |
Dell r750 | NIC.Integrated.1-1-1 |
Every other method that requires passing the -i
argument, is going to parse the key strings from this and look for the most adequate candidate for the given FQDN.
We format the key strings with the following criteria:
{host_type}_[{rack}_[{ULocation}_[{blade}_]]]{model}_interfaces
With rack, ULocation and blade being optional in a hierarchical fashion otherwise mandatory, ergo you can't define blade without ULocation and so forth. host_type and model values are always mandatory.
Keys defined on interfaces yaml | FQDN | Use boot order |
---|---|---|
director_r620_interfaces | mgmt-f21-h17-000-r620.domain.com | NO |
director_f21_r620_interfaces | mgmt-f21-h17-000-r620.domain.com | NO |
director_f21_h17_r620_interfaces | mgmt-f21-h17-000-r620.domain.com | YES |
Keys defined on interfaces yaml | FQDN | Use boot order |
---|---|---|
director_r620_interfaces | mgmt-f21-h18-000-r620.domain.com | NO |
director_f21_r620_interfaces | mgmt-f21-h18-000-r620.domain.com | YES |
director_f21_h17_r620_interfaces | mgmt-f21-h18-000-r620.domain.com | NO |
Keys defined on interfaces yaml | FQDN | Use boot order |
---|---|---|
director_r620_interfaces | mgmt-f22-h17-000-r620.domain.com | YES |
director_f21_r620_interfaces | mgmt-f22-h17-000-r620.domain.com | NO |
director_f21_h17_r620_interfaces | mgmt-f22-h17-000-r620.domain.com | NO |
Please refer to our contributing guide.
- Here is some useful documentation
- You can find us on IRC in
#badfish
(or#quads
) onirc.libera.chat
if you have questions or need help. Click here to join in your browser.