Notifications
You must be signed in to change notification settings - Fork 113
Grott Configuration
The "behaviour" of Grott can be specified at 3 places:
- At startup
- Via environmental variables (mostly used as Grott runs in a Docker container)
- In the configuration file (standard: grott.ini, example can be found at: https://github.com/johanmeijer/grott/tree/master/examples)
Startup commands parameters overides, environmentals and configuration file settings
Environmentals overides configuration file settings
With version 2.1.1 automatic protocol detection is introduced and the known inverters are recognized automatically. The .ini settings can be very limited.
The default values (nothing specified) can be used if only MQTT needs to be enabled (without security) and MQTT is running at the same machine as Grott
Specify MQTT ip.
nomqtt=True (If no MQTT msg needs to be sent)
pvoutput = True
apikey = yourapikey
systemid = yoursystemid
The configuration file is defined in 4 sections. A general section, one for specifing the growatt server details, one for specifing the MQTT broker information and one for the PVOutput.org settings.
Since version 2.1.1 Automatic prototcol detection can be used
Specify compat = False (default) specifing other parms like valueoffset or decrypt is not needed anymore (this solves also remark 1)
ADD/ Change Growatt server section only as the server has changed (to be announced by Growatt) Not defining the MQTT section will sent messages the local MQTT server implementation.
Since March 2020 offset has been changed for some inverters.
Add compat = True, valueoffset = 26 to support this change if automatic protocol detection is not used(see also remark1!!!)
Start-up | Config file (.ini) | Environmental Variable | Description |
---|---|---|---|
[Startup only ] | |||
-h, --help | Show help message and exit | ||
-t, --trace | Enable trace, use in addition to verbose option (only available in sniff mode) | ||
--version | Show program's version number and exit | ||
-c [config file] | Sets config file if not specified config file is grott.ini | ||
-o [output file] | Set output file, if not specified output is stdout | ||
[Generic ] | |||
-v, --verbose | verbose=True/False | gverbose=True/False | Specify verbose for extended messaging Default: Verbose = False |
minrecl = xxx | gminrecl = xxx | Debug/Perfomance parameter. Doesnot process record less then specified recl. Default: minrecl=100. In normal operation no need for change |
|
-m [mode] | mode =sniff/proxy | gmode =sniff/proxy | Set mode (sniff or proxy) Default: mode=proxy (from version 2.1 and higher) |
#ip = 0.0.0.0 | ip = x.x.x.x | ggrottip = x.x.x.x | Specify IP address to listen to (proxy mode only) Default: ip=0.0.0.0 (server IP address), In normal operation no need for change |
#port = 5279 | port = yyyy | ggrottport = yyyy | Specify port to listen to (proxy mode only) Default port= 5279 , In normal operation no need for change |
-b, --blockcmd | blockcmd=True/False | gblockcmd=True/False | Blocks commands from outside (to change inverter and shine devices settings) Default: blockcmd=False |
-n, --noipf | noipf=True/False | gnoipf=True/False | Allow Growatt IP address changes from outside (if commands are blocked with blockcmd=True) Default: noipf=False (advice only use this for a short testing period) |
compat= True/False | gompat=True/False | Enable / disable automatic protocol processing Default: compat=False ,In normal operation no need for change |
|
valueoffset=x | gvalueoffset=x | Set offset of data record, can only be used in combination with compat=True Default: valueoffset=6 (since 2020, most off data records start at 26) |
|
decrypt=True | gdecrypt=True | Specify if data record needs to decrypted, can only be used in combination with compat=True Default: decrypt=True |
|
-i [inverterid] | inverterid=ABC1234567 | ginverterid=ABC1234567 | Specify inverter id, needs to be be used in combination with compat=True Default: inverterid=automatic |
[Growatt] | |||
ip=x.x.x.x | ggrowattip=x.x.x.x | Ip address of Growatt server (specify only if IP has changed) Default: ip = 47.91.67.66 |
|
port=yyyy | ggrowattport=yyyy | IP port of Growatt server (specify only if IP has changed) Default: ip = 5279 |
|
[MQTT] | |||
-nm, --nomqtt | #nomqtt=True/False | gnomqtt=True/False | Disable mqtt send (be aware nomqtt = True means no MQTT processing will be done) Default nomqtt=False |
ip=x.x.x.x | gmqttip=x.x.x.x | IP address of MQTT server Default ip=local (MQTT server runs at same servef as growatt) |
|
port=yyyy | gmqttip=yyyy | IP port of MQTT server Default: ip = 1883 |
|
topic=namex/namey | gmqtttopic=namex/namey | Topic name where MQTT message is published Default: topic= energy/growatt |
|
auth=True/False | gmqttauth=True/False | Use MQTT Security Default: auth=False (no mqtt security used) |
|
user=grott | gmqttuser = grott | MQTT User (only used if MQTT security is enabled, mqttauth=True) Default: user=grott |
|
password = growatt2020 | gmqttpassword=growatt2020 | MQTT password (only used if MQTT security is enabled, mqttauth=True) Default: user=growatt2020 |
|
[PVOutput] | |||
-p, --pvoutput | pvoutput=True/False | gpvoutput=True/False | Enable pvoutput send Default: pvoutput=False |
apikey = yourapikey | gpvapikey = yourapikey | PVOutput.org apikey (only used if pvoutput=True), use this only if you have 1 inverter use this if you have 1 inverter |
|
systemid = 12345 | gpvsystemid = | PVOutput.org systemid (only used if pvoutput=True), use this if you have 1 inverter |
|
systemidX = | gpvsystemidX = | PVOutput.org systemid (only used if pvoutput=True) use this if you have 1 or more inverters (>release 2.2.6), x = number (e.g 1,2,3 etc) |
|
inverteridX = | gpinverteridX = | Specify inverterid for pvoutput systemidX use this if you have 1 or more inverters (>release 2.2.6), x = number (e.g 1,2,3 etc) |
|
systemidX+1 = <pv output ssidX+1> | gpvsystemidX+1 = <pv output ssidX+1> | PVOutput.org systemid (only used if pvoutput=True) use this if you have 1 or more inverters (>release 2.2.6), x = number (e.g 2,3 etc) |
|
inverteridX+1 = <inverteridX+1> | gpinverteridX+1 = <inverteridX+1> | Specify inverterid for pvoutput systemidX use this if you have 1 or more inverters (>release 2.2.6), x = number (e.g 2,3 etc) |
|
[extension] | |||
extension = True | gextension = True | enable / disable extention | |
extname = ext_name | gextname = ext_name | extension name | |
extvar = {"var1": "value"} | gextvar = {"var1": "value"} | define variables to be used in the extension | |