Description
Describe the bug
Overnight the planer was set to charge the car. Despite the continuous option enabled, the charging was not continuous. At first the car was only charged for 15 minutes, then the charging paused for 45 minutes and started again.
The logs below show that for the first and second charging period the planer calculated the same average cost of 0.311 euros/kwh.
Steps to reproduce
The following was observed:
- The planer was set to charge a car until 7:00 with the continuous option enabled.
- At first the planer estimates to start the charging at 4:00:
Jan 31 03:59:50 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 03:59:50 plan: charge 1h35m39s between 2026-01-31 04:00:00 +0100 CET until 2026-01-31 07:00:00 +0100 CET (power: 13800W, avg cost: 0.311) - The charging starts as planed:
INFO 2026/01/31 04:00:40 start charging -> - Four minutes later a new start date (5:00) is calculated:
DEBUG 2026/01/31 04:04:50 plan: continuing until end of slot at 2026-01-31 04:15:00 +0100 CET
DEBUG 2026/01/31 04:05:00 plan: charge 1h32m9s between 2026-01-31 05:00:00 +0100 CET until 2026-01-31 07:00:00 +0100 CET (power: 13800W, avg cost: 0.311) - The charging is stopped at 4:15
INFO 2026/01/31 04:15:10 stop charging <- - Then the charging starts again at 5:00
INFO 2026/01/31 05:00:30 start charging ->
Configuration details
{
"site": {
"title": "",
"grid": "db:7",
"pv": ["db:5"],
"battery": ["db:6"],
"aux": null,
"ext": null
},
"loadpoints": [
{"id":11,"name":"db:11","charger":"db:10","vehicle":"db:3","title":"Garage","defaultMode":"pv","priority":0,"phasesConfigured":0,"minCurrent":6,"maxCurrent":20,"smartCostLimit":null,"smartFeedInPriorityLimit":null,"planEnergy":0,"planTime":"0001-01-01T00:00:00Z","planPrecondition":0,"limitEnergy":0,"limitSoc":0,"planStrategy":{"continuous":true,"precondition":0},"thresholds":{"enable":{"delay":120000000000,"threshold":0},"disable":{"delay":300000000000,"threshold":0}},"soc":{"poll":{"mode":"charging","interval":3600000000000},"estimate":true}}
],
"charger": [
{"config":{"host":"192.168.178.164","template":"go-e-v3"},"deviceProduct":"go-e Charger Gemini","id":10,"name":"db:10","type":"template"}
],
"meter": [
{"config":{"host":"192.168.178.49","maxacpower":"0","port":"502","template":"victron-energy","usage":"grid"},"deviceProduct":"Victron Energy","id":7,"name":"db:7","type":"template"},
{"config":{"capacity":21,"host":"192.168.178.49","maxacpower":"0","maxchargepower":3500,"maxdischargepower":5000,"minsoc":15,"port":"502","template":"victron-energy","usage":"battery"},"deviceProduct":"Victron Energy","deviceTitle":"Batterie","id":6,"name":"db:6","type":"template"},
{"config":{"host":"192.168.178.49","maxacpower":0,"port":"502","template":"victron-energy","usage":"pv"},"deviceProduct":"Victron Energy","deviceTitle":"PV-Anlage","id":5,"name":"db:5","type":"template"}
],
"vehicle": [
{"config":{"capacity":40,"icon":"car","maxCurrent":32,"maxPower":22000,"minCurrent":10,"mode":"pv","phases":"","template":"offline","title":"ZOE"},"deviceProduct":"Generisches Fahrzeug (ohne API)","id":3,"name":"db:3","type":"template"},
{"config":{"cache":"15m","capacity":87,"coarsecurrent":false,"icon":"car","maxCurrent":20,"maxPower":11000,"maxcurrent":20,"maxpower":11000,"minCurrent":6,"mincurrent":6,"mode":"pv","password":"***","phases":"","template":"renault","title":"Scenic","user":"***","vin":"***","wakeupmode":"default"},"deviceProduct":"Renault","id":4,"name":"db:4","type":"template"}
],
"tariffs": "currency: EUR
grid: # price using energy from the grid
# type: fixed
# price: 0.294 # EUR/kWh
type: template
template: energy-charts-api
bzn: DE-LU
charges: 0.1675
tax: 0.19
feedin: # price for feeding solar energy to the grid
type: fixed
price: 0.10 # EUR/kWh
#co2: # carbon intensity forecast
# type: template
# template: grünstromindex
# zip: *****
solar: # list of pv generation forecast (additive)
- type: template
template: open-meteo
lat: *****
lon: *****
dec: 45
kwp: 7
az: 0
dm: 50
- type: template
template: open-meteo
lat: *****
lon: *****
dec: 15
kwp: 3
az: 0",
"mqtt": {"broker":"192.168.178.49:1883","user":"","password":"","clientID":"","insecure":false,"caCert":"","clientCert":"","clientKey":"","topic":"evcc"},
"influx": {"url":"","database":"","token":"","org":"","user":"","password":"","insecure":false},
"shm": {"vendorId":"","deviceId":""},
"interval": 10
}Log details
Jan 31 03:59:50 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 03:59:50 charge power: 0W
Jan 31 03:59:50 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 03:59:50 charge currents: [0 0 0]A
Jan 31 03:59:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 03:59:50 battery 1 power: -0W
Jan 31 03:59:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 03:59:50 grid power: 208W
Jan 31 03:59:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 03:59:50 battery 1 soc: 15%
Jan 31 03:59:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 03:59:50 pv 1 power: 0W
Jan 31 03:59:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 03:59:50 !! solar production: accumulate add db:5 0.000W power (was: Accumulated: 369.839kWh updated: 2026-01-31 03:59:40 +0100 CET)
Jan 31 03:59:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 03:59:50 !! solar production: accumulate moved db:5 from 369.839 to 369.839
Jan 31 03:59:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 03:59:50 site power: 308W
Jan 31 03:59:50 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 03:59:50 charge voltages: [225 226 226]V
Jan 31 03:59:50 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 03:59:50 charge total import: 3125.225kWh
Jan 31 03:59:50 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 03:59:50 charger status: B
Jan 31 03:59:50 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 03:59:50 plan: charge 1h35m39s between 2026-01-31 04:00:00 +0100 CET until 2026-01-31 07:00:00 +0100 CET (power: 13800W, avg cost: 0.311)
Jan 31 03:59:50 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 03:59:50 pv charge current: 0A = 0A + -1.34A (308W @ 1p)
Jan 31 03:59:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 03:59:50 solar forecast: accumulated 0.000Wh from 2026-01-31 03:59:40 +0100 CET to 2026-01-31 03:59:50 +0100 CET
Jan 31 03:59:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 03:59:50 solar forecast: produced 369.839
Jan 31 03:59:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 03:59:50 solar forecast: accumulated 419.045kWh, produced 369.839kWh, scale 0.883
Jan 31 04:00:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:00 ----
Jan 31 04:00:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:00 charge power: 0W
Jan 31 04:00:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:00 charge currents: [0 0 0]A
Jan 31 04:00:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:00 battery 1 power: -0W
Jan 31 04:00:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:00 grid power: 209W
Jan 31 04:00:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:00 battery 1 soc: 15%
Jan 31 04:00:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:00 pv 1 power: 0W
Jan 31 04:00:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:00 !! solar production: accumulate add db:5 0.000W power (was: Accumulated: 369.839kWh updated: 2026-01-31 03:59:50 +0100 CET)
Jan 31 04:00:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:00 !! solar production: accumulate moved db:5 from 369.839 to 369.839
Jan 31 04:00:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:00 site power: 309W
Jan 31 04:00:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:00 15min household consumption: 0Wh
Jan 31 04:00:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:00 charge voltages: [225 226 225]V
Jan 31 04:00:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:00 charge total import: 3125.225kWh
Jan 31 04:00:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:00 charger status: B
Jan 31 04:00:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:00 plan: charge 1h35m39s between 2026-01-31 04:00:00 +0100 CET until 2026-01-31 07:00:00 +0100 CET (power: 13800W, avg cost: 0.311)
Jan 31 04:00:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:00 switched phases: 3p
Jan 31 04:00:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:00 wake-up timer: start
Jan 31 04:00:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:00 set charge current limit: 20A
Jan 31 04:00:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:00 charger enable
Jan 31 04:00:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:00 wake-up timer: start
Jan 31 04:00:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:00 pv timer elapse
Jan 31 04:00:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:00 pv timer inactive
Jan 31 04:00:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:00 solar forecast: accumulated 0.000Wh from 2026-01-31 03:59:50 +0100 CET to 2026-01-31 04:00:00 +0100 CET
Jan 31 04:00:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:00 solar forecast: produced 369.839
Jan 31 04:00:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:00 solar forecast: accumulated 419.045kWh, produced 369.839kWh, scale 0.883
Jan 31 04:00:10 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:10 ----
Jan 31 04:00:10 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:10 charge power: 0W
Jan 31 04:00:10 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:10 charge currents: [0 0 0]A
Jan 31 04:00:10 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:10 battery 1 power: -0W
Jan 31 04:00:10 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:10 grid power: 208W
Jan 31 04:00:10 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:10 battery 1 soc: 15%
Jan 31 04:00:10 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:10 pv 1 power: 0W
Jan 31 04:00:10 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:10 !! solar production: accumulate add db:5 0.000W power (was: Accumulated: 369.839kWh updated: 2026-01-31 04:00:00 +0100 CET)
Jan 31 04:00:10 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:10 !! solar production: accumulate moved db:5 from 369.839 to 369.839
Jan 31 04:00:10 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:10 site power: 308W
Jan 31 04:00:10 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:10 charge voltages: [225 226 226]V
Jan 31 04:00:10 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:10 charge total import: 3125.225kWh
Jan 31 04:00:10 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:10 charger status: B
Jan 31 04:00:10 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:10 plan: charge 1h35m39s between 2026-01-31 04:00:10 +0100 CET until 2026-01-31 07:00:00 +0100 CET (power: 13800W, avg cost: 0.311)
Jan 31 04:00:10 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:10 solar forecast: accumulated 0.000Wh from 2026-01-31 04:00:00 +0100 CET to 2026-01-31 04:00:10 +0100 CET
Jan 31 04:00:10 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:10 solar forecast: produced 369.839
Jan 31 04:00:10 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:10 solar forecast: accumulated 419.045kWh, produced 369.839kWh, scale 0.883
Jan 31 04:00:20 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:20 ----
Jan 31 04:00:20 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:20 charge power: 0W
Jan 31 04:00:20 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:20 charge currents: [0 0 0]A
Jan 31 04:00:20 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:20 battery 1 power: -0W
Jan 31 04:00:20 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:20 grid power: 211W
Jan 31 04:00:20 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:20 battery 1 soc: 15%
Jan 31 04:00:20 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:20 pv 1 power: 0W
Jan 31 04:00:20 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:20 !! solar production: accumulate add db:5 0.000W power (was: Accumulated: 369.839kWh updated: 2026-01-31 04:00:10 +0100 CET)
Jan 31 04:00:20 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:20 !! solar production: accumulate moved db:5 from 369.839 to 369.839
Jan 31 04:00:20 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:20 site power: 311W
Jan 31 04:00:20 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:20 charge voltages: [225 226 225]V
Jan 31 04:00:20 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:20 charge total import: 3125.225kWh
Jan 31 04:00:20 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:20 charger status: B
Jan 31 04:00:20 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:20 plan: charge 1h35m39s between 2026-01-31 04:00:20 +0100 CET until 2026-01-31 07:00:00 +0100 CET (power: 13800W, avg cost: 0.311)
Jan 31 04:00:20 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:20 solar forecast: accumulated 0.000Wh from 2026-01-31 04:00:10 +0100 CET to 2026-01-31 04:00:20 +0100 CET
Jan 31 04:00:20 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:20 solar forecast: produced 369.839
Jan 31 04:00:20 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:20 solar forecast: accumulated 419.045kWh, produced 369.839kWh, scale 0.883
Jan 31 04:00:30 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:30 ----
Jan 31 04:00:30 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:30 charge power: 0W
Jan 31 04:00:30 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:30 charge currents: [0 0 0]A
Jan 31 04:00:30 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:30 battery 1 power: -0W
Jan 31 04:00:30 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:30 grid power: 207W
Jan 31 04:00:30 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:30 battery 1 soc: 15%
Jan 31 04:00:30 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:30 pv 1 power: 0W
Jan 31 04:00:30 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:30 !! solar production: accumulate add db:5 0.000W power (was: Accumulated: 369.839kWh updated: 2026-01-31 04:00:20 +0100 CET)
Jan 31 04:00:30 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:30 !! solar production: accumulate moved db:5 from 369.839 to 369.839
Jan 31 04:00:30 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:30 site power: 307W
Jan 31 04:00:30 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:30 charge voltages: [225 226 225]V
Jan 31 04:00:30 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:30 charge total import: 3125.225kWh
Jan 31 04:00:30 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:30 charger status: B
Jan 31 04:00:30 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:30 plan: charge 1h35m39s between 2026-01-31 04:00:30 +0100 CET until 2026-01-31 07:00:00 +0100 CET (power: 13800W, avg cost: 0.311)
Jan 31 04:00:30 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:30 solar forecast: accumulated 0.000Wh from 2026-01-31 04:00:20 +0100 CET to 2026-01-31 04:00:30 +0100 CET
Jan 31 04:00:30 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:30 solar forecast: produced 369.839
Jan 31 04:00:30 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:30 solar forecast: accumulated 419.045kWh, produced 369.839kWh, scale 0.883
Jan 31 04:00:40 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:40 ----
Jan 31 04:00:40 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:40 charge power: 12360W
Jan 31 04:00:40 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:40 charge currents: [18.7 18.9 19]A
Jan 31 04:00:40 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:40 battery 1 power: -0W
Jan 31 04:00:40 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:40 grid power: 12940W
Jan 31 04:00:40 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:40 battery 1 soc: 15%
Jan 31 04:00:40 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:40 pv 1 power: 0W
Jan 31 04:00:40 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:40 !! solar production: accumulate add db:5 0.000W power (was: Accumulated: 369.839kWh updated: 2026-01-31 04:00:30 +0100 CET)
Jan 31 04:00:40 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:40 !! solar production: accumulate moved db:5 from 369.839 to 369.839
Jan 31 04:00:40 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:40 site power: 13040W
Jan 31 04:00:40 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:40 charge voltages: [220 222 221]V
Jan 31 04:00:40 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:40 charge total import: 3125.238kWh
Jan 31 04:00:40 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:40 charger status: C
Jan 31 04:00:40 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:40 charge start energy: 3125.238kWh
Jan 31 04:00:40 t440p evcc[179231]: [lp-1 ] INFO 2026/01/31 04:00:40 start charging ->
Jan 31 04:00:40 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:40 wake-up timer: stop
Jan 31 04:00:40 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:40 plan: charge 1h35m39s between 2026-01-31 04:00:40 +0100 CET until 2026-01-31 07:00:00 +0100 CET (power: 13800W, avg cost: 0.311)
Jan 31 04:00:40 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:40 solar forecast: accumulated 0.000Wh from 2026-01-31 04:00:30 +0100 CET to 2026-01-31 04:00:40 +0100 CET
Jan 31 04:00:40 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:40 solar forecast: produced 369.839
Jan 31 04:00:40 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:40 solar forecast: accumulated 419.045kWh, produced 369.839kWh, scale 0.883
Jan 31 04:00:40 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:40 set battery Batterie mode: hold
Jan 31 04:00:40 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:40 set battery mode: hold
Jan 31 04:00:45 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:45 telemetry: upload failed: Post "https://api.evcc.io/v1/charge": context deadline exceeded
Jan 31 04:00:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:50 ----
Jan 31 04:00:50 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:50 charge power: 12362W
Jan 31 04:00:50 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:50 charge currents: [18.7 18.8 19]A
Jan 31 04:00:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:50 battery 1 power: -0W
Jan 31 04:00:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:50 grid power: 12949W
Jan 31 04:00:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:50 battery 1 soc: 15%
Jan 31 04:00:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:50 pv 1 power: 0W
Jan 31 04:00:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:50 !! solar production: accumulate add db:5 0.000W power (was: Accumulated: 369.839kWh updated: 2026-01-31 04:00:40 +0100 CET)
Jan 31 04:00:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:50 !! solar production: accumulate moved db:5 from 369.839 to 369.839
Jan 31 04:00:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:50 site power: 13049W
Jan 31 04:00:50 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:50 charge voltages: [220 222 221]V
Jan 31 04:00:50 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:50 session energy: 0.035kWh
Jan 31 04:00:50 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:50 charge total import: 3125.273kWh
Jan 31 04:00:50 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:50 charger status: C
Jan 31 04:00:50 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:00:50 plan: charge 1h35m30s between 2026-01-31 04:00:50 +0100 CET until 2026-01-31 07:00:00 +0100 CET (power: 13800W, avg cost: 0.311)
Jan 31 04:00:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:50 solar forecast: accumulated 0.000Wh from 2026-01-31 04:00:40 +0100 CET to 2026-01-31 04:00:50 +0100 CET
Jan 31 04:00:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:50 solar forecast: produced 369.839
Jan 31 04:00:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:00:50 solar forecast: accumulated 419.045kWh, produced 369.839kWh, scale 0.883
Jan 31 04:01:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:01:00 ----
Jan 31 04:01:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:01:00 charge power: 12353W
Jan 31 04:01:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:01:00 charge currents: [18.7 18.8 19]A
Jan 31 04:01:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:01:00 battery 1 power: -0W
Jan 31 04:01:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:01:00 grid power: 12912W
Jan 31 04:01:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:01:00 battery 1 soc: 15%
Jan 31 04:01:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:01:00 pv 1 power: 0W
Jan 31 04:01:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:01:00 !! solar production: accumulate add db:5 0.000W power (was: Accumulated: 369.839kWh updated: 2026-01-31 04:00:50 +0100 CET)
Jan 31 04:01:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:01:00 !! solar production: accumulate moved db:5 from 369.839 to 369.839
Jan 31 04:01:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:01:00 site power: 13012W
Jan 31 04:01:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:01:00 charge voltages: [220 221 221]V
Jan 31 04:01:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:01:00 session energy: 0.070kWh
Jan 31 04:01:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:01:00 charge total import: 3125.308kWh
Jan 31 04:01:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:01:00 charger status: C
Jan 31 04:01:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:01:00 plan: charge 1h35m21s between 2026-01-31 04:01:00 +0100 CET until 2026-01-31 07:00:00 +0100 CET (power: 13800W, avg cost: 0.311)
Jan 31 04:01:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:01:00 solar forecast: accumulated 0.000Wh from 2026-01-31 04:00:50 +0100 CET to 2026-01-31 04:01:00 +0100 CET
Jan 31 04:01:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:01:00 solar forecast: produced 369.839
Jan 31 04:01:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:01:00 solar forecast: accumulated 419.045kWh, produced 369.839kWh, scale 0.883
Jan 31 04:01:10 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:01:10 ----
Jan 31 04:04:40 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:04:40 ----
Jan 31 04:04:40 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:04:40 charge power: 10587W
Jan 31 04:04:40 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:04:40 charge currents: [16.3 16.5 16.5]A
Jan 31 04:04:40 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:04:40 battery 1 power: -0W
Jan 31 04:04:40 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:04:40 battery 1 soc: 15%
Jan 31 04:04:40 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:04:40 grid power: 11199W
Jan 31 04:04:40 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:04:40 pv 1 power: 0W
Jan 31 04:04:40 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:04:40 !! solar production: accumulate add db:5 0.000W power (was: Accumulated: 369.839kWh updated: 2026-01-31 04:04:30 +0100 CET)
Jan 31 04:04:40 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:04:40 !! solar production: accumulate moved db:5 from 369.839 to 369.839
Jan 31 04:04:40 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:04:40 site power: 11299W
Jan 31 04:04:40 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:04:40 charge voltages: [221 223 222]V
Jan 31 04:04:40 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:04:40 detected active phases: 3p
Jan 31 04:04:40 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:04:40 session energy: 0.748kWh
Jan 31 04:04:40 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:04:40 charge total import: 3125.986kWh
Jan 31 04:04:40 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:04:40 charger status: C
Jan 31 04:04:40 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:04:40 plan: charge 1h32m24s between 2026-01-31 04:04:40 +0100 CET until 2026-01-31 07:00:00 +0100 CET (power: 13800W, avg cost: 0.311)
Jan 31 04:04:40 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:04:40 solar forecast: accumulated 0.000Wh from 2026-01-31 04:04:30 +0100 CET to 2026-01-31 04:04:40 +0100 CET
Jan 31 04:04:40 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:04:40 solar forecast: produced 369.839
Jan 31 04:04:40 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:04:40 solar forecast: accumulated 419.045kWh, produced 369.839kWh, scale 0.883
Jan 31 04:04:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:04:50 ----
Jan 31 04:04:50 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:04:50 charge power: 10589W
Jan 31 04:04:50 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:04:50 charge currents: [16.3 16.4 16.5]A
Jan 31 04:04:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:04:50 battery 1 power: -0W
Jan 31 04:04:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:04:50 grid power: 11214W
Jan 31 04:04:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:04:50 battery 1 soc: 15%
Jan 31 04:04:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:04:50 pv 1 power: 0W
Jan 31 04:04:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:04:50 !! solar production: accumulate add db:5 0.000W power (was: Accumulated: 369.839kWh updated: 2026-01-31 04:04:40 +0100 CET)
Jan 31 04:04:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:04:50 !! solar production: accumulate moved db:5 from 369.839 to 369.839
Jan 31 04:04:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:04:50 site power: 11314W
Jan 31 04:04:50 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:04:50 charge voltages: [221 222 222]V
Jan 31 04:04:50 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:04:50 detected active phases: 3p
Jan 31 04:04:50 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:04:50 session energy: 0.778kWh
Jan 31 04:04:50 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:04:50 charge total import: 3126.016kWh
Jan 31 04:04:50 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:04:50 charger status: C
Jan 31 04:04:50 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:04:50 plan: charge 1h32m16s between 2026-01-31 05:00:00 +0100 CET until 2026-01-31 07:00:00 +0100 CET (power: 13800W, avg cost: 0.311)
Jan 31 04:04:50 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:04:50 plan: continuing until end of slot at 2026-01-31 04:15:00 +0100 CET
Jan 31 04:04:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:04:50 solar forecast: accumulated 0.000Wh from 2026-01-31 04:04:40 +0100 CET to 2026-01-31 04:04:50 +0100 CET
Jan 31 04:04:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:04:50 solar forecast: produced 369.839
Jan 31 04:04:50 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:04:50 solar forecast: accumulated 419.045kWh, produced 369.839kWh, scale 0.883
Jan 31 04:05:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:05:00 ----
Jan 31 04:05:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:05:00 charge power: 10590W
Jan 31 04:05:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:05:00 charge currents: [16.3 16.5 16.5]A
Jan 31 04:05:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:05:00 battery 1 power: -0W
Jan 31 04:05:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:05:00 grid power: 11222W
Jan 31 04:05:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:05:00 battery 1 soc: 15%
Jan 31 04:05:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:05:00 pv 1 power: 0W
Jan 31 04:05:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:05:00 !! solar production: accumulate add db:5 0.000W power (was: Accumulated: 369.839kWh updated: 2026-01-31 04:04:50 +0100 CET)
Jan 31 04:05:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:05:00 !! solar production: accumulate moved db:5 from 369.839 to 369.839
Jan 31 04:05:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:05:00 site power: 11322W
Jan 31 04:05:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:05:00 charge voltages: [221 223 222]V
Jan 31 04:05:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:05:00 detected active phases: 3p
Jan 31 04:05:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:05:00 session energy: 0.807kWh
Jan 31 04:05:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:05:00 charge total import: 3126.045kWh
Jan 31 04:05:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:05:00 charger status: C
Jan 31 04:05:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:05:00 plan: charge 1h32m9s between 2026-01-31 05:00:00 +0100 CET until 2026-01-31 07:00:00 +0100 CET (power: 13800W, avg cost: 0.311)
Jan 31 04:05:00 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:05:00 plan: continuing until end of slot at 2026-01-31 04:15:00 +0100 CET
Jan 31 04:05:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:05:00 solar forecast: accumulated 0.000Wh from 2026-01-31 04:04:50 +0100 CET to 2026-01-31 04:05:00 +0100 CET
Jan 31 04:05:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:05:00 solar forecast: produced 369.839
Jan 31 04:05:00 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:05:00 solar forecast: accumulated 419.045kWh, produced 369.839kWh, scale 0.883
Jan 31 04:05:10 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:05:10 ----
Jan 31 04:05:10 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:05:10 charge power: 10595W
Jan 31 04:05:10 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:05:10 charge currents: [16.3 16.4 16.5]A
Jan 31 04:05:10 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:05:10 battery 1 power: -0W
Jan 31 04:05:10 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:05:10 grid power: 11188W
Jan 31 04:05:10 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:05:10 battery 1 soc: 15%
Jan 31 04:05:10 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:05:10 pv 1 power: 0W
Jan 31 04:05:10 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:05:10 !! solar production: accumulate add db:5 0.000W power (was: Accumulated: 369.839kWh updated: 2026-01-31 04:05:00 +0100 CET)
Jan 31 04:05:10 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:05:10 !! solar production: accumulate moved db:5 from 369.839 to 369.839
Jan 31 04:05:10 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:05:10 site power: 11288W
Jan 31 04:05:10 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:05:10 charge voltages: [221 222 222]V
Jan 31 04:05:10 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:05:10 detected active phases: 3p
Jan 31 04:05:10 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:05:10 session energy: 0.837kWh
Jan 31 04:05:10 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:05:10 charge total import: 3126.075kWh
Jan 31 04:05:10 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:05:10 charger status: C
Jan 31 04:05:10 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:05:10 plan: charge 1h32m1s between 2026-01-31 05:00:00 +0100 CET until 2026-01-31 07:00:00 +0100 CET (power: 13800W, avg cost: 0.311)
Jan 31 04:05:10 t440p evcc[179231]: [lp-1 ] DEBUG 2026/01/31 04:05:10 plan: continuing until end of slot at 2026-01-31 04:15:00 +0100 CET
Jan 31 04:05:10 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:05:10 solar forecast: accumulated 0.000Wh from 2026-01-31 04:05:00 +0100 CET to 2026-01-31 04:05:10 +0100 CET
Jan 31 04:05:10 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:05:10 solar forecast: produced 369.839
Jan 31 04:05:10 t440p evcc[179231]: [site ] DEBUG 2026/01/31 04:05:10 solar forecast: accumulated 419.045kWh, produced 369.839kWh, scale 0.883
What type of operating system or environment does evcc run on?
Linux
External automation
- I have made sure that no external automation like HomeAssistant or Node-RED is active or accessing any of the mentioned devices when this issue occurs.
Nightly build
- I have verified that the issue is reproducible with the latest nightly build
Version
evcc version 0.300.7
Reactions are currently unavailable
Metadata
Metadata
Assignees
Labels
enhancementNew feature or requestNew feature or requestneeds decisionUnsure if we should really do thisUnsure if we should really do thisunfortunateNot nice but also not easily fixableNot nice but also not easily fixable