Disable "auto" selector for IS-04-04, IS-05-03, IS-09-02 & BCP-003-01 #820

Open
wants to merge 5 commits into
base: master
Choose a base branch
from

Conversation

jonathan-r-thorpe
Copy link
Contributor

This solves #671

  • Includes disable_auto optional key in test suite definition found in NMOSTesting.py
  • Constructor parameters (including disable_auto) passed through to GenericTest.py for test suites:
    • IS-04-04
    • IS-05-03
    • IS-09-02
    • BCP-003-01

@garethsb
Copy link
Contributor

What's the relationship between this and the technique in the IS-12 suite mentioned in #809?

@jonathan-r-thorpe
Copy link
Contributor Author

This is removing the auto option altogether whereas #809 is for stopping the test suite from auto testing a particular API - in the case of IS-12, to stop it from auto testing IS-04