94 changes: 94 additions & 0 deletions zhaquirks/owon/Owon_PC321_Z.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,94 @@
"""Quirk for Owon PC321 Z."""

from zigpy.profiles import zha
from zigpy.quirks import CustomCluster, CustomDevice
import zigpy.types as t
from zigpy.zcl.clusters.general import Basic, Identify
from zigpy.zcl.clusters.smartenergy import Metering

from zhaquirks.const import (
DEVICE_TYPE,
ENDPOINTS,
INPUT_CLUSTERS,
MODELS_INFO,
OUTPUT_CLUSTERS,
PROFILE_ID,
)
from zhaquirks.owon import Owon

class Owon_PC321_Z_Simple_Metering(CustomCluster, Metering):
"""Owon PC321 CustomCluster"""

ep_attribute: str = "owon_smartenergy_metering"
exelsis423 marked this conversation as resolved.
Show resolved Hide resolved

attributes = Metering.attributes.copy()
attributes.update(
{
0x2000: ("L1_phase_power", t.uint24_t, True),
0x2001: ("L2_phase_power", t.uint24_t, True),
0x2002: ("L3_phase_power", t.uint24_t, True),
0x2100: ("L1_phase_reactive_power", t.uint24_t, True),
0x2101: ("L2_phase_reactive_power", t.uint24_t, True),
0x2102: ("L3_phase_reactive_power", t.uint24_t, True),
0x2103: ("reactive_power_summation_of_the_3_phases", t.uint24_t, True),
0x3000: ("L1_phase_voltage", t.uint24_t, True),
0x3001: ("L2_phase_voltage", t.uint24_t, True),
0x3002: ("L3_phase_voltage", t.uint24_t, True),
0x3100: ("L1_phase_current", t.uint24_t, True),
0x3101: ("L2_phase_current", t.uint24_t, True),
0x3102: ("L3_phase_current", t.uint24_t, True),
0x3103: ("current_summation_of_the_3_phases", t.uint24_t, True),
0x3104: ("leakage_current", t.uint24_t, True),
0x4000: ("L1_phase_energy_consumption", t.uint48_t, True),
0x4001: ("L2_phase_energy_consumption", t.uint48_t, True),
0x4002: ("L3_phase_energy_consumption", t.uint48_t, True),
0x4100: ("L1_phase_reactive_energy_consumption", t.uint48_t, True),
0x4101: ("L2_phase_reactive_energy_consumption", t.uint48_t, True),
0x4102: ("L3_phase_reactive_energy_consumption", t.uint48_t, True),
0x4103: ("reactive_energy_summation_of_the_3_phases", t.uint48_t, True),
0x5005: ("frequency", t.uint8_t, True),
}
)



class Owon_PC321_Z(CustomDevice):
"""New Device Owon PC321 Z."""
signature = {
MODELS_INFO: [(Owon, "PC321")],
ENDPOINTS: {
# <SimpleDescriptor endpoint=1 profile=260 device_type=13
# device_version=1
# input_clusters=[0, 3, 1794]
# output_clusters=[3]>
1: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.CONSUMPTION_AWARENESS_DEVICE,
INPUT_CLUSTERS: [
Basic.cluster_id,
Identify.cluster_id,
Metering.cluster_id,
],
OUTPUT_CLUSTERS: [Identify.cluster_id],
},
},
#"manufacturer": "OWON Technology Inc.",
}
replacement = {
ENDPOINTS: {
# <SimpleDescriptor endpoint=1 profile=260 device_type=13
# device_version=1
# input_clusters=[0, 3, 1794]
# output_clusters=[3]>
1: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.CONSUMPTION_AWARENESS_DEVICE,
INPUT_CLUSTERS: [
Basic.cluster_id,
Identify.cluster_id,
Owon_PC321_Z_Simple_Metering,
],
OUTPUT_CLUSTERS: [Identify.cluster_id],
},
},
}
3 changes: 3 additions & 0 deletions zhaquirks/owon/__init__.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,3 @@
"""Owon quirks."""

Owon = "OWON Technology Inc."
Loading