Problem description
Similar device aded to solve the following issue #3124
My device is detected as TS0601 _TZE200_7ytb3h8u
Bought here: https://fr.aliexpress.com/item/1005006548852233.html
Solution description
I succesfully aded the device by adding the above model in
MODELS_INFO: [("_TZE200_sh1btabb", "TS0601"), ("_TZE200_a7sghmms", "TS0601"), ( "_TZE204_7ytb3h8u", "TS0601")], |
I'm rather new with domotic and Home Assistant, I'm not skilled enough to get a zigbee to MQTT dump for now, then I did a try after roughly understanding how the ZHA quirks works.
Screenshots/Video
Screenshots/Video
[Paste/upload your media here]
Device signature
Device signature
{
"node_descriptor": "NodeDescriptor(logical_type=<LogicalType.EndDevice: 2>, complex_descriptor_available=0, user_descriptor_available=0, reserved=0, aps_flags=0, frequency_band=<FrequencyBand.Freq2400MHz: 8>, mac_capability_flags=<MACCapabilityFlags.AllocateAddress: 128>, manufacturer_code=4417, maximum_buffer_size=66, maximum_incoming_transfer_size=66, server_mask=10752, maximum_outgoing_transfer_size=66, descriptor_capability_field=<DescriptorCapability.NONE: 0>, *allocate_address=True, *is_alternate_pan_coordinator=False, *is_coordinator=False, *is_end_device=True, *is_full_function_device=False, *is_mains_powered=False, *is_receiver_on_when_idle=False, *is_router=False, *is_security_capable=False)",
"endpoints": {
"1": {
"profile_id": "0x0104",
"device_type": "0x0000",
"input_clusters": [
"0x0000",
"0x0001",
"0x0004",
"0x0005",
"0x0006",
"0x0702",
"0xef00"
],
"output_clusters": [
"0x000a",
"0x0019"
]
}
},
"manufacturer": "_TZE200_7ytb3h8u",
"model": "TS0601",
"class": "ts0601_valve.GiexValve"
}
Diagnostic information
Diagnostic information
{
"home_assistant": {
"installation_type": "Home Assistant Container",
"version": "2024.6.2",
"dev": false,
"hassio": false,
"virtualenv": false,
"python_version": "3.12.2",
"docker": true,
"arch": "aarch64",
"timezone": "Europe/Paris",
"os_name": "Linux",
"os_version": "6.2.0-1018-raspi",
"run_as_root": true
},
"custom_components": {},
"integration_manifest": {
"domain": "zha",
"name": "Zigbee Home Automation",
"after_dependencies": [
"onboarding",
"usb"
],
"codeowners": [
"dmulcahey",
"adminiuga",
"puddly",
"TheJulianJES"
],
"config_flow": true,
"dependencies": [
"file_upload"
],
"documentation": "https://www.home-assistant.io/integrations/zha",
"iot_class": "local_polling",
"loggers": [
"aiosqlite",
"bellows",
"crccheck",
"pure_pcapy3",
"zhaquirks",
"zigpy",
"zigpy_deconz",
"zigpy_xbee",
"zigpy_zigate",
"zigpy_znp",
"universal_silabs_flasher"
],
"requirements": [
"bellows==0.39.0",
"pyserial==3.5",
"zha-quirks==0.0.116",
"zigpy-deconz==0.23.1",
"zigpy==0.64.0",
"zigpy-xbee==0.20.1",
"zigpy-zigate==0.12.0",
"zigpy-znp==0.12.1",
"universal-silabs-flasher==0.0.20",
"pyserial-asyncio-fast==0.11"
],
"usb": [
{
"vid": "10C4",
"pid": "EA60",
"description": "*2652*",
"known_devices": [
"slae.sh cc2652rb stick"
]
},
{
"vid": "10C4",
"pid": "EA60",
"description": "*slzb-07*",
"known_devices": [
"smlight slzb-07"
]
},
{
"vid": "1A86",
"pid": "55D4",
"description": "*sonoff*plus*",
"known_devices": [
"sonoff zigbee dongle plus v2"
]
},
{
"vid": "10C4",
"pid": "EA60",
"description": "*sonoff*plus*",
"known_devices": [
"sonoff zigbee dongle plus"
]
},
{
"vid": "10C4",
"pid": "EA60",
"description": "*tubeszb*",
"known_devices": [
"TubesZB Coordinator"
]
},
{
"vid": "1A86",
"pid": "7523",
"description": "*tubeszb*",
"known_devices": [
"TubesZB Coordinator"
]
},
{
"vid": "1A86",
"pid": "7523",
"description": "*zigstar*",
"known_devices": [
"ZigStar Coordinators"
]
},
{
"vid": "1CF1",
"pid": "0030",
"description": "*conbee*",
"known_devices": [
"Conbee II"
]
},
{
"vid": "0403",
"pid": "6015",
"description": "*conbee*",
"known_devices": [
"Conbee III"
]
},
{
"vid": "10C4",
"pid": "8A2A",
"description": "*zigbee*",
"known_devices": [
"Nortek HUSBZB-1"
]
},
{
"vid": "0403",
"pid": "6015",
"description": "*zigate*",
"known_devices": [
"ZiGate+"
]
},
{
"vid": "10C4",
"pid": "EA60",
"description": "*zigate*",
"known_devices": [
"ZiGate"
]
},
{
"vid": "10C4",
"pid": "8B34",
"description": "*bv 2010/10*",
"known_devices": [
"Bitron Video AV2010/10"
]
}
],
"zeroconf": [
{
"type": "_esphomelib._tcp.local.",
"name": "tube*"
},
{
"type": "_zigate-zigbee-gateway._tcp.local.",
"name": "*zigate*"
},
{
"type": "_zigstar_gw._tcp.local.",
"name": "*zigstar*"
},
{
"type": "_uzg-01._tcp.local.",
"name": "uzg-01*"
},
{
"type": "_slzb-06._tcp.local.",
"name": "slzb-06*"
}
],
"is_built_in": true
},
"setup_times": {
"null": {
"setup": 0.00021338602527976036
},
"0ffe77e8ceb946efe67b9ae06341980c": {
"wait_import_platforms": -0.0004412168636918068,
"wait_base_component": -0.001689257100224495,
"config_entry_setup": 13.71825297595933
}
},
"data": {
"ieee": "**REDACTED**",
"nwk": 47845,
"manufacturer": "_TZE200_7ytb3h8u",
"model": "TS0601",
"name": "_TZE200_7ytb3h8u TS0601",
"quirk_applied": true,
"quirk_class": "ts0601_valve.GiexValve",
"quirk_id": null,
"manufacturer_code": 4417,
"power_source": "Battery or Unknown",
"lqi": null,
"rssi": null,
"last_seen": "2024-06-16T16:15:49",
"available": true,
"device_type": "EndDevice",
"signature": {
"node_descriptor": "NodeDescriptor(logical_type=<LogicalType.EndDevice: 2>, complex_descriptor_available=0, user_descriptor_available=0, reserved=0, aps_flags=0, frequency_band=<FrequencyBand.Freq2400MHz: 8>, mac_capability_flags=<MACCapabilityFlags.AllocateAddress: 128>, manufacturer_code=4417, maximum_buffer_size=66, maximum_incoming_transfer_size=66, server_mask=10752, maximum_outgoing_transfer_size=66, descriptor_capability_field=<DescriptorCapability.NONE: 0>, *allocate_address=True, *is_alternate_pan_coordinator=False, *is_coordinator=False, *is_end_device=True, *is_full_function_device=False, *is_mains_powered=False, *is_receiver_on_when_idle=False, *is_router=False, *is_security_capable=False)",
"endpoints": {
"1": {
"profile_id": "0x0104",
"device_type": "0x0000",
"input_clusters": [
"0x0000",
"0x0001",
"0x0004",
"0x0005",
"0x0006",
"0x0702",
"0xef00"
],
"output_clusters": [
"0x000a",
"0x0019"
]
}
},
"manufacturer": "_TZE200_7ytb3h8u",
"model": "TS0601"
},
"active_coordinator": false,
"entities": [
{
"entity_id": "sensor.electrovanne_batterie",
"name": "_TZE200_7ytb3h8u TS0601"
},
{
"entity_id": "sensor.electrovanne_demande_instantanee",
"name": "_TZE200_7ytb3h8u TS0601"
},
{
"entity_id": "sensor.electrovanne_summation_delivered",
"name": "_TZE200_7ytb3h8u TS0601"
},
{
"entity_id": "switch.electrovanne_commutateur",
"name": "_TZE200_7ytb3h8u TS0601"
},
{
"entity_id": "update.electrovanne_micrologiciel",
"name": "_TZE200_7ytb3h8u TS0601"
}
],
"neighbors": [],
"routes": [],
"endpoint_names": [
{
"name": "ON_OFF_SWITCH"
}
],
"user_given_name": "electrovanne",
"device_reg_id": "c8a695ef6f9e50c5dda150243ce08909",
"area_id": "arbres_fruitiers",
"cluster_details": {
"1": {
"device_type": {
"name": "ON_OFF_SWITCH",
"id": 0
},
"profile_id": 260,
"in_clusters": {
"0x0000": {
"endpoint_attribute": "basic",
"attributes": {
"0x0001": {
"attribute_name": "app_version",
"value": 72
},
"0x0004": {
"attribute_name": "manufacturer",
"value": "_TZE200_7ytb3h8u"
},
"0x0005": {
"attribute_name": "model",
"value": "TS0601"
}
},
"unsupported_attributes": {}
},
"0x0004": {
"endpoint_attribute": "groups",
"attributes": {},
"unsupported_attributes": {}
},
"0x0005": {
"endpoint_attribute": "scenes",
"attributes": {},
"unsupported_attributes": {}
},
"0x0006": {
"endpoint_attribute": "on_off",
"attributes": {
"0x0000": {
"attribute_name": "on_off",
"value": 0
}
},
"unsupported_attributes": {}
},
"0x0001": {
"endpoint_attribute": "power",
"attributes": {
"0x0021": {
"attribute_name": "battery_percentage_remaining",
"value": 400
}
},
"unsupported_attributes": {}
},
"0x0702": {
"endpoint_attribute": "smartenergy_metering",
"attributes": {
"0x0000": {
"attribute_name": "current_summ_delivered",
"value": 0
},
"0x0306": {
"attribute_name": "metering_device_type",
"value": 2
},
"0x0300": {
"attribute_name": "unit_of_measure",
"value": 7
}
},
"unsupported_attributes": {}
},
"0xef00": {
"endpoint_attribute": "tuya_manufacturer",
"attributes": {
"0xef72": {
"attribute_name": "irrigation_duration",
"value": "00:00:00,0"
},
"0xef66": {
"attribute_name": "irrigation_end_time",
"value": "05:36:38"
},
"0xef69": {
"attribute_name": "irrigation_interval",
"value": 0
},
"0xef01": {
"attribute_name": "irrigation_mode",
"value": 0
},
"0xef67": {
"attribute_name": "irrigation_num_times",
"value": 0
},
"0xef65": {
"attribute_name": "irrigation_start_time",
"value": "05:36:38"
},
"0xef68": {
"attribute_name": "irrigation_target",
"value": 0
},
"0xef00": {
"attribute_name": "mcu_version",
"value": "1.0.0"
}
},
"unsupported_attributes": {}
}
},
"out_clusters": {
"0x000a": {
"endpoint_attribute": "time",
"attributes": {},
"unsupported_attributes": {}
},
"0x0019": {
"endpoint_attribute": "ota",
"attributes": {
"0x0002": {
"attribute_name": "current_file_version",
"value": 72
}
},
"unsupported_attributes": {}
}
}
}
}
}
}
Logs
Logs
[Paste the logs here]
Custom quirk
ts0601_valve.py
"""Collection of Tuya Valve devices e.g. water valves, gas valve etc."""
from zigpy.profiles import zha
from zigpy.quirks import CustomDevice
import zigpy.types as t
from zigpy.zcl import foundation
from zigpy.zcl.clusters.general import Basic, Groups, Identify, OnOff, Ota, Scenes, Time
from zigpy.zcl.clusters.smartenergy import Metering
from zhaquirks import DoublingPowerConfigurationCluster
from zhaquirks.const import (
DEVICE_TYPE,
ENDPOINTS,
INPUT_CLUSTERS,
MODELS_INFO,
OUTPUT_CLUSTERS,
PROFILE_ID,
)
from zhaquirks.tuya import EnchantedDevice, TuyaLocalCluster
from zhaquirks.tuya.mcu import (
DPToAttributeMapping,
TuyaMCUCluster,
TuyaOnOff,
TuyaOnOffNM,
TuyaPowerConfigurationCluster,
)
class TuyaValveWaterConsumed(Metering, TuyaLocalCluster):
"""Tuya Valve Water consumed cluster."""
VOLUME_LITERS = 0x0007
WATER_METERING = 0x02
"""Setting unit of measurement."""
_CONSTANT_ATTRIBUTES = {
0x0300: VOLUME_LITERS,
0x0306: WATER_METERING,
}
class TuyaValveManufCluster(TuyaMCUCluster):
"""On/Off Tuya cluster with extra device attributes."""
attributes = TuyaMCUCluster.attributes.copy()
attributes.update(
{
0xEF01: ("time_left", t.uint32_t, True),
0xEF02: ("state", t.enum8, True),
0xEF03: ("last_valve_open_duration", t.uint32_t, True),
0xEF04: ("dp_6", t.uint32_t, True),
0xEF05: ("valve_position", t.uint32_t, True),
}
)
dp_to_attribute: dict[int, DPToAttributeMapping] = {
1: DPToAttributeMapping(
TuyaOnOff.ep_attribute,
"on_off",
),
5: DPToAttributeMapping(
TuyaValveWaterConsumed.ep_attribute,
"current_summ_delivered",
),
6: DPToAttributeMapping(
TuyaMCUCluster.ep_attribute,
"dp_6",
),
7: DPToAttributeMapping(
DoublingPowerConfigurationCluster.ep_attribute,
"battery_percentage_remaining",
),
11: DPToAttributeMapping(
TuyaMCUCluster.ep_attribute,
"time_left",
),
12: DPToAttributeMapping(
TuyaMCUCluster.ep_attribute,
"state",
),
15: DPToAttributeMapping(
TuyaMCUCluster.ep_attribute,
"last_valve_open_duration",
),
102: DPToAttributeMapping(
TuyaMCUCluster.ep_attribute,
"valve_position",
),
}
data_point_handlers = {
1: "_dp_2_attr_update",
5: "_dp_2_attr_update",
6: "_dp_2_attr_update",
7: "_dp_2_attr_update",
11: "_dp_2_attr_update",
12: "_dp_2_attr_update",
15: "_dp_2_attr_update",
102: "_dp_2_attr_update",
}
class TuyaValve(CustomDevice):
"""Tuya valve device."""
signature = {
MODELS_INFO: [("_TZE200_81isopgh", "TS0601")],
# SizePrefixedSimpleDescriptor(endpoint=1, profile=260, device_type=81, device_version=1,
# input_clusters=[0, 4, 5, 61184], output_clusters=[25, 10])
ENDPOINTS: {
1: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.SMART_PLUG,
INPUT_CLUSTERS: [
Basic.cluster_id,
Groups.cluster_id,
Scenes.cluster_id,
TuyaValveManufCluster.cluster_id,
],
OUTPUT_CLUSTERS: [Time.cluster_id, Ota.cluster_id],
}
},
}
replacement = {
ENDPOINTS: {
1: {
DEVICE_TYPE: zha.DeviceType.SMART_PLUG,
INPUT_CLUSTERS: [
Basic.cluster_id,
Groups.cluster_id,
Scenes.cluster_id,
TuyaOnOff,
TuyaValveWaterConsumed,
DoublingPowerConfigurationCluster,
TuyaValveManufCluster,
],
OUTPUT_CLUSTERS: [Time.cluster_id, Ota.cluster_id],
}
}
}
class BasicTuyaValve(CustomDevice):
"""Basic Tuya valve device."""
signature = {
MODELS_INFO: [("_TZE200_1n2zev06", "TS0601")],
# SizePrefixedSimpleDescriptor(endpoint=1, profile=260, device_type=81, device_version=1,
# input_clusters=[0, 4, 5, 61184], output_clusters=[25, 10])
ENDPOINTS: {
1: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.SMART_PLUG,
INPUT_CLUSTERS: [
Basic.cluster_id,
Groups.cluster_id,
Scenes.cluster_id,
TuyaValveManufCluster.cluster_id,
],
OUTPUT_CLUSTERS: [Time.cluster_id, Ota.cluster_id],
}
},
}
replacement = {
ENDPOINTS: {
1: {
DEVICE_TYPE: zha.DeviceType.SMART_PLUG,
INPUT_CLUSTERS: [
Basic.cluster_id,
Groups.cluster_id,
Scenes.cluster_id,
TuyaOnOff,
TuyaValveManufCluster,
],
OUTPUT_CLUSTERS: [Time.cluster_id, Ota.cluster_id],
}
}
}
class ParksideTuyaValveManufCluster(TuyaMCUCluster):
"""Manufacturer Specific Cluster for the _TZE200_htnnfasr water valve sold as PARKSIDE."""
attributes = TuyaMCUCluster.attributes.copy()
attributes.update(
{
0xEF11: ("timer_duration", t.uint32_t, True),
0xEF12: ("timer_time_left", t.uint32_t, True),
0xEF13: ("frost_lock", t.Bool, True),
0xEF14: ("frost_lock_reset", t.Bool, True), # 0 resets frost lock
}
)
dp_to_attribute: dict[int, DPToAttributeMapping] = {
1: DPToAttributeMapping(
TuyaOnOff.ep_attribute,
"on_off",
),
5: DPToAttributeMapping(
TuyaMCUCluster.ep_attribute,
"timer_duration",
),
6: DPToAttributeMapping(
TuyaMCUCluster.ep_attribute,
"timer_time_left",
),
11: DPToAttributeMapping(
TuyaPowerConfigurationCluster.ep_attribute,
"battery_percentage_remaining",
),
108: DPToAttributeMapping(
TuyaMCUCluster.ep_attribute,
"frost_lock",
lambda x: not x, # invert for lock entity
),
109: DPToAttributeMapping(
TuyaMCUCluster.ep_attribute,
"frost_lock_reset",
),
}
data_point_handlers = {
1: "_dp_2_attr_update",
5: "_dp_2_attr_update",
6: "_dp_2_attr_update",
11: "_dp_2_attr_update",
108: "_dp_2_attr_update",
109: "_dp_2_attr_update",
}
async def bind(self):
"""Bind cluster.
When adding this device tuya gateway issues factory reset,
we just need to reset the frost lock, because its state is unknown to us.
"""
result = await super().bind()
await self.write_attributes({self.attributes_by_name["frost_lock_reset"].id: 0})
return result
class ParksidePSBZS(EnchantedDevice):
"""LIDL Parkside water without implemented scheduler."""
signature = {
MODELS_INFO: [("_TZE200_htnnfasr", "TS0601")], # HG06875
ENDPOINTS: {
# <SimpleDescriptor endpoint=1 profile=260 device_type=0
# device_version=1
# input_clusters=[0, 1, 3, 4, 5, 6, 61184]
# output_clusters=[10, 25]>
1: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.ON_OFF_SWITCH,
INPUT_CLUSTERS: [
Basic.cluster_id,
Identify.cluster_id,
Groups.cluster_id,
Scenes.cluster_id,
OnOff.cluster_id,
ParksideTuyaValveManufCluster.cluster_id,
],
OUTPUT_CLUSTERS: [Time.cluster_id, Ota.cluster_id],
},
},
}
replacement = {
ENDPOINTS: {
1: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.ON_OFF_SWITCH,
INPUT_CLUSTERS: [
Basic.cluster_id,
Identify.cluster_id,
Groups.cluster_id,
Scenes.cluster_id,
TuyaOnOff,
TuyaPowerConfigurationCluster,
ParksideTuyaValveManufCluster,
],
OUTPUT_CLUSTERS: [Time.cluster_id, Ota.cluster_id],
},
},
}
# info from https://github.com/Koenkk/zigbee-herdsman-converters/blob/master/devices/giex.js
GIEX_MODE_ATTR = 0xEF01 # Mode [0] duration [1] capacity
GIEX_START_TIME_ATTR = 0xEF65 # Last irrigation start time (GMT)
GIEX_END_TIME_ATTR = 0xEF66 # Last irrigation end time (GMT)
GIEX_NUM_TIMES_ATTR = 0xEF67 # Number of cycle irrigation times min=0 max=100
GIEX_TARGET_ATTR = 0xEF68 # Irrigation target, duration in sec or capacity in litres (depending on mode) min=0 max=3600
GIEX_INTERVAL_ATTR = 0xEF69 # Cycle irrigation interval in seconds min=0 max=3600
GIEX_DURATION_ATTR = 0xEF72 # Last irrigation duration
class GiexValveManufCluster(TuyaMCUCluster):
"""GiEX valve manufacturer cluster."""
attributes = TuyaMCUCluster.attributes.copy()
attributes.update(
{
GIEX_MODE_ATTR: ("irrigation_mode", t.Bool, True),
GIEX_START_TIME_ATTR: ("irrigation_start_time", t.uint32_t, True),
GIEX_END_TIME_ATTR: ("irrigation_end_time", t.uint32_t, True),
GIEX_NUM_TIMES_ATTR: ("irrigation_num_times", t.uint32_t, True),
GIEX_TARGET_ATTR: ("irrigation_target", t.uint32_t, True),
GIEX_INTERVAL_ATTR: ("irrigation_interval", t.uint32_t, True),
GIEX_DURATION_ATTR: ("irrigation_duration", t.uint32_t, True),
}
)
dp_to_attribute: dict[int, DPToAttributeMapping] = {
1: DPToAttributeMapping(
TuyaMCUCluster.ep_attribute,
"irrigation_mode",
),
2: DPToAttributeMapping(
TuyaOnOffNM.ep_attribute,
"on_off",
),
101: DPToAttributeMapping(
TuyaMCUCluster.ep_attribute,
"irrigation_start_time",
),
102: DPToAttributeMapping(
TuyaMCUCluster.ep_attribute,
"irrigation_end_time",
),
103: DPToAttributeMapping(
TuyaMCUCluster.ep_attribute,
"irrigation_num_times",
),
104: DPToAttributeMapping(
TuyaMCUCluster.ep_attribute,
"irrigation_target",
),
105: DPToAttributeMapping(
TuyaMCUCluster.ep_attribute,
"irrigation_interval",
),
108: DPToAttributeMapping(
TuyaPowerConfigurationCluster.ep_attribute,
"battery_percentage_remaining",
),
111: DPToAttributeMapping(
TuyaValveWaterConsumed.ep_attribute,
"current_summ_delivered",
),
114: DPToAttributeMapping(
TuyaMCUCluster.ep_attribute,
"irrigation_duration",
),
}
data_point_handlers = {
1: "_dp_2_attr_update",
2: "_dp_2_attr_update",
101: "_dp_2_attr_update",
102: "_dp_2_attr_update",
103: "_dp_2_attr_update",
104: "_dp_2_attr_update",
105: "_dp_2_attr_update",
108: "_dp_2_attr_update",
111: "_dp_2_attr_update",
114: "_dp_2_attr_update",
}
async def write_attributes(self, attributes, manufacturer=None):
"""Overwrite to force manufacturer code."""
return await super().write_attributes(
attributes, manufacturer=foundation.ZCLHeader.NO_MANUFACTURER_ID
)
class GiexValve(CustomDevice):
"""GiEX valve device."""
signature = {
MODELS_INFO: [("_TZE200_sh1btabb", "TS0601"), ("_TZE200_a7sghmms", "TS0601"), ( "_TZE204_7ytb3h8u", "TS0601"), ("_TZE200_7ytb3h8u", "TS0601")],
ENDPOINTS: {
# <SimpleDescriptor endpoint=1 profile=260 device_type=0x0051
# input_clusters=[0x0000, 0x0004, 0x0005, 0xef00]
# output_clusters=[0x000a, 0x0019]>
1: {
PROFILE_ID: zha.PROFILE_ID,
DEVICE_TYPE: zha.DeviceType.SMART_PLUG,
INPUT_CLUSTERS: [
Basic.cluster_id,
Groups.cluster_id,
Scenes.cluster_id,
GiexValveManufCluster.cluster_id,
],
OUTPUT_CLUSTERS: [Time.cluster_id, Ota.cluster_id],
}
},
}
replacement = {
ENDPOINTS: {
1: {
DEVICE_TYPE: zha.DeviceType.ON_OFF_SWITCH,
INPUT_CLUSTERS: [
Basic.cluster_id,
Groups.cluster_id,
Scenes.cluster_id,
TuyaOnOffNM,
TuyaPowerConfigurationCluster,
TuyaValveWaterConsumed,
GiexValveManufCluster,
],
OUTPUT_CLUSTERS: [Time.cluster_id, Ota.cluster_id],
}
}
}
Additional information
Enable / disable test done
No response
Metadata
Metadata
Assignees
Labels
TuyaRequest/PR regarding a Tuya deviceRequest/PR regarding a Tuya device