1 change: 1 addition & 0 deletions dbus-modbus-client.py
Original file line number Diff line number Diff line change
Expand Up @@ -34,6 +34,7 @@
import ev_charger
import smappee
import victron_em
import shelly

import logging
log = logging.getLogger()
Expand Down
228 changes: 228 additions & 0 deletions shelly.py
Original file line number Diff line number Diff line change
@@ -0,0 +1,228 @@
import device
import probe
from register import *

# This Python script adds support for Modbus enabled Shelly devices in dbus-modbus-client version 1.58 and later.
#

# This is just a helper class to make life a bit easier with the Modbus registers.
#
class Reg_shelly(Reg_f32l):
def __init__(self, base, name=None, scale=1, text=None, write=False, invalid=[], **kwargs):
super().__init__(base - 30000, name, scale, text, write, invalid, **kwargs)

# Shelly Pro 3EM
# https://shelly-api-docs.shelly.cloud/gen2/Devices/Gen2/ShellyPro3EM
#
# Triphase (defualt)
# https://shelly-api-docs.shelly.cloud/gen2/ComponentsAndServices/EM/
# https://shelly-api-docs.shelly.cloud/gen2/ComponentsAndServices/EMData/
#
# Monophase
# https://shelly-api-docs.shelly.cloud/gen2/ComponentsAndServices/EM1/
# https://shelly-api-docs.shelly.cloud/gen2/ComponentsAndServices/EM1Data/
#
# Modbus
# https://shelly-api-docs.shelly.cloud/gen2/ComponentsAndServices/Modbus
#
class Shelly_Pro_Meter(device.CustomName, device.EnergyMeter):
vendor_id = 'shelly'
vendor_name = 'Shelly'
min_timeout = 0.5

# Shelly uses input registers!
default_access = 'input'

# Subclasses must set the following three properties!
# productname
# productmodel
# productid

def device_init(self):
self.info_regs = [
Reg_text(0, 6, '/Serial', little=True),
]

em_components = self.em_components()

# Monophase
if em_components < 0:
self.init_monophase(em_components)

# Triphase (default)
else:
self.init_triphase(em_components)

#
# Initializer for the Shelly Monophase profile.
#
def init_monophase(self, em_components):
em_components = abs(em_components)

if em_components > 3:
raise Exception('Too many EM components: %d' % em_components)

self.nr_phases = em_components

self.data_regs = [
# NOTE: We leave the 'AC Totals' blank as the monophase profile does not
# provide us the totals.
]

for n in range(em_components):
phase = n + 1

em_offset = n * 20
data_offset = n * 20

self.data_regs += [
Reg_shelly(32003 + em_offset, '/Ac/L%d/Voltage' % phase, 1, '%.1f V'),
Reg_shelly(32005 + em_offset, '/Ac/L%d/Current' % phase, 1, '%.1f A'),
Reg_shelly(32310 + data_offset, '/Ac/L%d/Energy/Forward' % phase, 1000, '%.1f kWh'),
Reg_shelly(32312 + data_offset, '/Ac/L%d/Energy/Reverse' % phase, 1000, '%.1f kWh'),
Reg_shelly(32007 + em_offset, '/Ac/L%d/Power' % phase, 1, '%.1f W'),
Reg_shelly(32011 + em_offset, '/Ac/L%d/PowerFactor' % phase, 1, '%.3f'),
]

#
# Initializer for the Shelly Triphase profile (default).
#
def init_triphase(self, em_components):

self.nr_phases = 3

#
# This is hypothetical but the Shelly documention does mention the possibility of
# more than one EM component in the Triphase profile. There is noting useful we
# can do with these components other than letting the user pick the one they want
# to show/use in the GX land.
#
component = 0
if component >= em_components:
raise Exception('EM component out of range: %d >= %d' % (component, em_components))

em_offset = component * 80
data_offset = component * 70

self.data_regs = [
Reg_shelly(31162 + data_offset, '/Ac/Energy/Forward', 1000, '%.1f kWh'),
Reg_shelly(31164 + data_offset, '/Ac/Energy/Reverse', 1000, '%.1f kWh'),
Reg_shelly(31013 + em_offset, '/Ac/Power', 1, '%.1f W'),
]

for n in range(self.nr_phases):
phase = n + 1

phase_em_offset = em_offset + (n * 20)
phase_data_offset = data_offset + (n * 20)

self.data_regs += [
Reg_shelly(31020 + phase_em_offset, '/Ac/L%d/Voltage' % phase, 1, '%.1f V'),
Reg_shelly(31022 + phase_em_offset, '/Ac/L%d/Current' % phase, 1, '%.1f A'),
Reg_shelly(31182 + phase_data_offset, '/Ac/L%d/Energy/Forward' % phase, 1000, '%.1f kWh'),
Reg_shelly(31184 + phase_data_offset, '/Ac/L%d/Energy/Reverse' % phase, 1000, '%.1f kWh'),
Reg_shelly(31024 + phase_em_offset, '/Ac/L%d/Power' % phase, 1, '%.1f W'),
Reg_shelly(31028 + phase_em_offset, '/Ac/L%d/PowerFactor' % phase, 1, '%.3f'),
]

#
# Attepts to read the given register and returns True upon success.
#
def check_register(self, reg):
try:
self.read_register(Reg_shelly(reg))
return True
except Exception as err:
self.log.info("No such Modbus register: %s", reg)
return False

#
# Returns the number of EM components. Negative numbers imply the Shelly device
# is operating in the Monophase profile. Postive numbers imply the device is
# operating in the Triphase profile.
#
def em_components(self):
# Monophase EM1:2
if self.check_register(32040):
return -3

# Monophase EM1:1
elif self.check_register(32020):
return -2

# Monophase EM1:0
elif self.check_register(32000):
return -1

# Triphase EM1
elif self.check_register(31080):
return 2

# Triphase EM0
elif self.check_register(31000):
return 1

else:
raise Exception("Unable to determine the number of EM components.")



# Shelly Pro 3EM
# https://www.shelly.com/products/shelly-pro-3em-x1
#
class Shelly_Pro_3EM(Shelly_Pro_Meter):
productname = 'Shelly Pro 3EM'
productmodel = 'SPEM-003CEBEU'
# P120
productid = 0x50313230

# Shelly Pro EM-50
# https://www.shelly.com/products/shelly-pro-em-50
#
class Shelly_Pro_EM50(Shelly_Pro_Meter):
productname = 'Shelly Pro EM-50'
productmodel = 'SPEM-002CEBEU50'
# P050
productid = 0x50303530

# Shelly Pro 3EM 3CT63
# https://www.shelly.com/products/shelly-pro-3em-3ct63
#
class Shelly_Pro_3EM_3CT63(Shelly_Pro_Meter):
productname = 'Shelly Pro 3EM 3CT63'
productmodel = 'SPEM-003CEBEU63'
# P063
productid = 0x50303633

# Shelly 3EM-63T or EM-63W Gen3
# https://www.shelly.com/products/shelly-3em-63t-gen3
# https://www.shelly.com/products/shelly-3em-63w-gen3
#
class Shelly_Pro_3EM_63_Gen3(Shelly_Pro_Meter):
productname = 'Shelly 3EM-63 Gen3'
productmodel = 'S3EM-003CXCEU63'
# P063
productid = 0x50303633

models = {
Shelly_Pro_3EM.productmodel: {
'model': Shelly_Pro_3EM.productmodel,
'handler': Shelly_Pro_3EM,
},
Shelly_Pro_EM50.productmodel: {
'model': Shelly_Pro_EM50.productmodel,
'handler': Shelly_Pro_EM50,
},
Shelly_Pro_3EM_3CT63.productmodel: {
'model': Shelly_Pro_3EM_3CT63.productmodel,
'handler': Shelly_Pro_3EM_3CT63,
},
Shelly_Pro_3EM_63_Gen3.productmodel: {
'model': Shelly_Pro_3EM_63_Gen3.productmodel,
'handler': Shelly_Pro_3EM_63_Gen3,
},
}

probe.add_handler(probe.ModelRegister(Reg_text(6, 10, 'model', little=True), models,
methods=['tcp'],