1.1
Pre-release
Pre-release
New features
- Speed can now be change for Low Speed (9600) send "s2" before sending "O" opening connection, any other value will set speed for 19200
- in Master Mode, period and wait for response time can now be change from default 15 ms, if you want to change do not setup frames using "t" or "r" but use upper case,
Format is as follows:
T0iiPPYY0ldd(dd) - In monitor mode to send a slave frame (no Break, Sync and PID) use
T000000iildd(dd)
where:
0 - zero
ii - id of frame
PP - time to wait in ms after sending this frame period
YY - time to wait for response after sending this frame
l - length
dd - data