fix and add global off, ventilation, and cooling mode from john30#191 (
Browse files Browse the repository at this point in the history
…closes john30#191), fix some defs
  • Loading branch information
john30 committed Jan 2, 2023
1 parent cc1cef6 commit 81162b5
Show file tree
Hide file tree
Showing 2 changed files with 20 additions and 2 deletions.
11 changes: 10 additions & 1 deletion ebusd-2.1.x/de/vaillant/15.700.csv
Original file line number Diff line number Diff line change
Expand Up @@ -3,9 +3,11 @@
# ##### Generell #####,,,,,,,,,,,,,
*r,,,,,,B524,02000000,,,IGN:4,,,
*w,,,,,,B524,02010000,,,,,,
*wi,#install,,,,,B524,02010000,,,,,,
r;w,,ContinuosHeating,Durchgehendes Heizen,,,,0200,,,tempv,,,"-26=off, when the outside temperature falls below this threshold temperature the continuous heating function is started (off <=> function is disabled)"
r;w,,FrostOverRideTime,Frostschutz-Verzögerung,,,,0300,,,hoursum2,,,delay before frost protection is activated
r;w,,ManualCooling,Manuell kühlen,,,,0600,,,UIN,,,Anzahl Tage manueller Kühlung (max. 99, 0=aus, Temperatur via z1CoolingTemp).
r;wi,,GlobalSystemOff,Global System Aus,,,,0700,,,yesno,,,Zum Ausschalten des Systems
r;w,,HwcParallelLoading,Parallele Ladung Warmwasserkreis,,,,0A00,,,onoff,,,Heizbetrieb und Speicherladung parallel
r;w,,MaxRoomHumidity,maxRoomHumidity,,,,0E00,,,UIN,,,maximale Raumluftfeuchte
r;w,,AdaptHeatCurve,Adaptive Heizkurve,,,,1400,,,yesno,,,automatic correction of configured heat curve
Expand All @@ -22,6 +24,8 @@ r;w,,HydraulicScheme,Systemschema,,,,3600,,,UIN,,,Systemschema
r,,WaterPressure,Wasserdruck,,,,3900,,,pressv,,,Wasserdruck
r;w,,SolarYieldTotal,TotalSolarYield,,,,3D00,,,energy4,,,Solarertrag gesamt
r;w,,YieldTotal,TotalEnvironmentalYield,,,,3E00,,,energy4,,,Umweltertrag gesamt
r;w,,VentilationDay,SollLüftung,,,,4200,,,UIN,,,Lüftergeschwindigkeit tagsüber
r;w,,VentilationNight,Absenklüftung,,,,4300,,,UIN,,,Lüftergeschwindigkeit nachts
r;w,,HwcMaxFlowTempDesired,HwcMaxFlowTempDesired,,,,4600,,,tempv,,,maximum flow temperature setpoint of Hwc
r,,SystemFlowTemp,Systemvorlauf,,,,4B00,,,tempv,,,Systemvorlauf
r;w,,MultiRelaySetting,Multifunktionsausgang,,,,4D00,,,mamode,,,
Expand Down Expand Up @@ -52,6 +56,8 @@ r,,DisplayedOutsideTemp,Außentemperatur,,,,7300,,,tempv,,,Außentemperatur
r;w,,SFMode,SFMode,,,,7400,,,sfmode,,,
r;w,,KeyCodeforConfigMenu,Passwort für das Konfigurationsmenü,,,,7600,,,UIN,,,000-999; code for the installer's menues
r;w,,OpMode,OpMode,,,,7b00,,,opmode,,,operation mode of all/configured zone(s) matching OpModeEffect
r;w,,OpModeCooling,,,,,7c00,,,opmode,,,Betriebsart für Kühlung aller/konfigurierter Zonen
r;w,,OpModeVentilation,,,,,1600,,,opmode,,,Betriebsart für Lüftung aller/konfigurierter Zonen
r;w,,HolidayTemp,HolidayTemp,,,,8200,,,tempv,,,holiday setpoint
r;w,,BankHolidayStartPeriod,BankHolidayStartPeriod,,,,8300,,,hfrom,,,start date of bank holidays
r;w,,BankHolidayEndPeriod,BankHolidayEndPeriod,,,,8400,,,hto,,,end date of bank holidays
Expand Down Expand Up @@ -143,6 +149,7 @@ r;w,,Hc3PumpStatus,PumpStatus Heizkreis 3,,,,1E00,,,UIN,,,pump status of zone 3
# ##### Zone 1 #####,,,,,,,,,,,,,
*r,,,,,,B524,02000300,,,IGN:4,,,
*w,,,,,,B524,02010300,,,,,,
r;w,,z1OpModeCooling,Betriebsart für Kühlung Zone 1,,,,0100,,,opmode,,,operation mode for cooling of zone 1
r;w,,z1CoolingTemp,Kühlsolltemperatur Zone 1,,,,0200,,,tempv,,,desired cooling setpoint for zone 1
r;w,,z1HolidayStartPeriod,Ferienzeitraum Start Zone 1,,,,0300,,,hfrom,,,start date of holidays for zone 1
r;w,,z1HolidayEndPeriod,Ferienzeitraum Ende Zone 1,,,,0400,,,hto,,,end date of holidays for zone 1
Expand All @@ -165,6 +172,7 @@ r;w,,z1Name2,Bezeichnung Zone 1 Teil 2,,,,1800,,,zname,,,name of zone 1
# ##### Zone 2 #####,,,,,,,,,,,,,
*r,,,,,,B524,02000301,,,IGN:4,,,
*w,,,,,,B524,02010301,,,,,,
r;w,,z2OpModeCooling,Betriebsart für Kühlung Zone 2,,,,0100,,,opmode,,,operation mode for cooling of zone 2
r;w,,z2CoolingTemp,Kühlsolltemperatur Zone 2,,,,0200,,,tempv,,,desired cooling setpoint for zone 2
r;w,,z2HolidayStartPeriod,Ferienzeitraum Start Zone 2,,,,0300,,,hfrom,,,start date of holidays for zone 2
r;w,,z2HolidayEndPeriod,Ferienzeitraum Ende Zone 2,,,,0400,,,hto,,,end date of holidays for zone 2
Expand All @@ -187,7 +195,8 @@ r;w,,z2Name2,Bezeichnung Zone 2 Teil 2,,,,1800,,,zname,,,name of zone 2
# ##### Zone 3 #####,,,,,,,,,,,,,
*r,,,,,,B524,02000302,,,IGN:4,,,
*w,,,,,,B524,02010302,,,,,,
#r;w,,z3Unknown02,(konstant 24 - Lüfterstufe?) Temperatur Zone 3,,,,0200,,,tempv,,,unknown value for zone 3
r;w,,z3OpModeCooling,Betriebsart für Kühlung Zone 3,,,,0100,,,opmode,,,operation mode for cooling of zone 3
r;w,,z3CoolingTemp,Kühlsolltemperatur Zone 3,,,,0200,,,tempv,,,desired cooling setpoint for zone 3
r;w,,z3HolidayStartPeriod,Ferienzeitraum Start Zone 3,,,,0300,,,hfrom,,,start date of holidays for zone 3
r;w,,z3HolidayEndPeriod,Ferienzeitraum Ende Zone 3,,,,0400,,,hto,,,end date of holidays for zone 3
r;w,,z3HolidayTemp,Raumsollwert Ferienbetrieb Zone 3,,,,0500,,,tempv,,,holiday setpoint for zone 3
Expand Down
11 changes: 10 additions & 1 deletion ebusd-2.1.x/en/vaillant/15.700.csv
Original file line number Diff line number Diff line change
Expand Up @@ -3,9 +3,11 @@
# ##### Generell #####,,,,,,,,,,,,,
*r,,,,,,B524,02000000,,,IGN:4,,,
*w,,,,,,B524,02010000,,,,,,
*wi,#install,,,,,B524,02010000,,,,,,
r;w,,ContinuosHeating,continuos heating,,,,0200,,,tempv,,,"-26=off, when the outside temperature falls below this threshold temperature the continuous heating function is started (off <=> function is disabled)"
r;w,,FrostOverRideTime,frost delay time,,,,0300,,,hoursum2,,,delay before frost protection is activated
r;w,,ManualCooling,Manual cooling,,,,0600,,,UIN,,,number of days of manual cooling (max. 99, 0=off, set temp via z1CoolingTemp).
r;wi,,GlobalSystemOff,Global System OFF,,,,0700,,,yesno,,,For switching system off
r;w,,HwcParallelLoading,hwc parallel loading,,,,0A00,,,onoff,,,heating and hot water parallel
r;w,,MaxRoomHumidity,max room humidity,,,,0E00,,,UIN,,,maximum room humidity
r;w,,AdaptHeatCurve,adaptive heat curve,,,,1400,,,yesno,,,automatic correction of configured heat curve
Expand All @@ -22,6 +24,8 @@ r;w,,HydraulicScheme,system schema,,,,3600,,,UIN,,,Systemschema
r,,WaterPressure,water pressure,,,,3900,,,pressv,,,Wasserdruck
r;w,,SolarYieldTotal,total solar yield,,,,3D00,,,energy4,,,Solarertrag gesamt
r;w,,YieldTotal,total environmental yield,,,,3E00,,,energy4,,,Umweltertrag gesamt
r;w,,VentilationDay,day ventilation speed,,,,4200,,,UIN,,,Ventilation speed during day
r;w,,VentilationNight,night ventilation,,,,4300,,,UIN,,,Ventilation speed during night
r;w,,HwcMaxFlowTempDesired,hwc max flow temp desired,,,,4600,,,tempv,,,maximum flow temperature setpoint of Hwc
r,,SystemFlowTemp,system flow temp,,,,4B00,,,tempv,,,Systemvorlauf
r;w,,MultiRelaySetting,multifunction relay setting,,,,4D00,,,mamode,,,
Expand Down Expand Up @@ -52,6 +56,8 @@ r,,DisplayedOutsideTemp,outside temperature,,,,7300,,,tempv,,,Außentemperatur
r;w,,SFMode,SF mode,,,,7400,,,sfmode,,,
r;w,,KeyCodeforConfigMenu,code for installer menu,,,,7600,,,UIN,,,000-999; code for the installer's menues
r;w,,OpMode,operation mode,,,,7b00,,,opmode,,,operation mode of all/configured zone(s) matching OpModeEffect
r;w,,OpModeCooling,operation mode for cooling,,,,7c00,,,opmode,,,operation mode for cooling of all/configured zone(s)
r;w,,OpModeVentilation,operation mode for ventilation,,,,1600,,,opmode,,,operation mode for ventilation of all/configured zone(s)
r;w,,HolidayTemp,holiday temperature,,,,8200,,,tempv,,,holiday setpoint
r;w,,BankHolidayStartPeriod,bank holiday start period,,,,8300,,,hfrom,,,start date of bank holidays
r;w,,BankHolidayEndPeriod,bank holiday end period,,,,8400,,,hto,,,end date of bank holidays
Expand Down Expand Up @@ -143,6 +149,7 @@ r;w,,Hc3PumpStatus,PumpStatus heating circuit 3,,,,1E00,,,UIN,,,pump status of z
# ##### zone 1 #####,,,,,,,,,,,,,
*r,,,,,,B524,02000300,,,IGN:4,,,
*w,,,,,,B524,02010300,,,,,,
r;w,,z1OpModeCooling,cooling operation mode zone 1,,,,0100,,,opmode,,,operation mode for cooling of zone 1
r;w,,z1CoolingTemp,cooling setpoint zone 1,,,,0200,,,tempv,,,desired cooling setpoint for zone 1
r;w,,z1HolidayStartPeriod,holiday period start zone 1,,,,0300,,,hfrom,,,start date of holidays for zone 1
r;w,,z1HolidayEndPeriod,holiday period end zone 1,,,,0400,,,hto,,,end date of holidays for zone 1
Expand All @@ -165,6 +172,7 @@ r;w,,z1Name2,zone 1 label (second part),,,,1800,,,zname,,,name of zone 1
# ##### zone 2 #####,,,,,,,,,,,,,
*r,,,,,,B524,02000301,,,IGN:4,,,
*w,,,,,,B524,02010301,,,,,,
r;w,,z2OpModeCooling,cooling operation mode zone 2,,,,0100,,,opmode,,,operation mode for cooling of zone 2
r;w,,z2CoolingTemp,cooling setpoint zone 2,,,,0200,,,tempv,,,desired cooling setpoint for zone 2
r;w,,z2HolidayStartPeriod,holiday period start zone 2,,,,0300,,,hfrom,,,start date of holidays for zone 2
r;w,,z2HolidayEndPeriod,holiday period end zone 2,,,,0400,,,hto,,,end date of holidays for zone 2
Expand All @@ -187,7 +195,8 @@ r;w,,z2Name2,zone 2 label (second part),,,,1800,,,zname,,,name of zone 2
# ##### zone 3 #####,,,,,,,,,,,,,
*r,,,,,,B524,02000302,,,IGN:4,,,
*w,,,,,,B524,02010302,,,,,,
#r;w,,z3Unknown02,(constant 24 - air level?) temperature zone 3,,,,0200,,,tempv,,,unknown value for zone 3
r;w,,z3OpModeCooling,cooling operation mode zone 3,,,,0100,,,opmode,,,operation mode for cooling of zone 3
r;w,,z3CoolingTemp,cooling setpoint zone 3,,,,0200,,,tempv,,,desired cooling setpoint for zone 3
r;w,,z3HolidayStartPeriod,holiday period start zone 3,,,,0300,,,hfrom,,,start date of holidays for zone 3
r;w,,z3HolidayEndPeriod,holiday period end zone 3,,,,0400,,,hto,,,end date of holidays for zone 3
r;w,,z3HolidayTemp,room setpoint holiday period zone 3,,,,0500,,,tempv,,,holiday setpoint for zone 3