Modification the max current setting of the kikusui agent (wire grid) #683
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
Description
In this pull request, I changed the max current setting about the wire grid kikusui agent. It was changed from 3.0 A to 4.5 A.
The kikusui power supply itself supports 18 V-5 A max in its specification. And this change will increase the motor's max torque, so the wire grid can rotate under lower temperatures.
Motivation and Context
Now the wire grid used for SAT-MF2 has an issue in that it cannot rotate under low ambient temperature, even though the grease in its bearing has temperature resistance. When I checked the rotation directly, the rotator can move with a small additional torque support by hand. Then, to make the rotation robust, we want to change the max current setting to 4.5 A.
How Has This Been Tested?
At the site, I changed the settings of the kikusui power supply manually, and confirmed the grid can rotate at 4.5 A max. Further, the over current protection in the hardware is now set at 4.9 A. So this change makes the rotation easy for the OCS operation as well.