coolscanpy is a direct-USB acquisition library for Nikon Coolscan film
scanners. It exposes a python-sane-style API: open a device, read and set
typed options, call scan() and get back an array. On top of that plain
surface it adds a roll-feeder extension for whole-roll workflows. A roll can
be previewed across all 40 addressable slots, each frame's transport spacing
adjusted individually, then batch-scanned in one continuous reservation.
Each scanned frame comes back as:
- scanner-linear RGB (4000 dpi, 16-bit)
- an aligned infrared plane
- the 285 dpi RGBI meter pass the scanner captured for auto-exposure (see
Frame.meter_rgbi) - an in-memory receipt with exposure, clipping, focus, and transport-smear telemetry
This code was extracted from a working NegPy integration branch. On real hardware, an LS-5000 running firmware 1.03 with an SA-21 roll feeder converted to SA-30 wiring, that integration produced full-roll previews and 4000 dpi 16-bit RGBI captures with receipts, and those captures fed the downstream dust-repair pipeline.
The current source tree collects 911 hardware-free tests covering the transport protocol, roll engine, capture finalization, receipt assembly, and public facade against synthetic fixtures and replay data. CI runs that suite and Ruff on Ubuntu and macOS with Python 3.13 and 3.14. Windows is not in the CI matrix and has not run the direct-USB transport against real hardware.
Live validation ran on 2026-07-18 with the packaged wheel installed into a
clean environment against a powered LS-5000, with no SANE installed: USB
enumeration, open(), option introspection, and a full roll preview of a
6-slot strip. The transport index read cleanly, slots 1 through 4 came
back aligned with no manual spacing offset, slot 5 was flagged for manual
review near the strip end, and slot 6 was correctly reported as a 2-row
trailing sliver rather than a frame. That run exposed one real bug, fixed
in 0.1.1: roll fingerprinting rejected strips with a trailing sliver.
The 0.1.3 short-strip fixes allow preview and fine scanning of strips shorter than a full roll. The current source also accepts the normal end-of-roll case where a fresh transport table has fewer usable records than the reviewed preview; it still refuses a count above the reviewed table, a mismatched visual fingerprint, or a requested slot that is no longer addressable.
The 285 dpi meter pass is now surfaced on every frame. The scanner already
captures three of these per frame during auto-exposure; the third (settled
exposure) is decoded and attached to the Frame. Downstream tools that
need a dual-capture (prepass + main) can use it directly. See the
downstream pipeline section.
C-41 fine scans expose RGB to Nikon Scan's rendering intent by default.
The auto-exposure loop still converges exactly as before, but the commanded
fine-scan RGB exposures are now a guarded Nikon-like target derived from
the settled meter pass. Live v3 validation used fine-scan fractions
R 0.950337, G 0.987481, and B 0.983639. Across three matched physical
frames, the Nikon-referenced full-scale channel biases were R +0.823…+2.086
%, G +0.146…+1.033 %, and B -0.391…+0.822 %, with a 0.9129 % mean absolute
bias. Under the explicitly defined complement statistic (100 % minus mean
absolute full-scale channel bias), that is 99.0871 % average full-scale
RGB-channel agreement. Mean 8x8-smoothed ΔE00 improved from 2.8469 to
2.1413 (-24.8 %). These figures describe this three-frame validation set;
they are neither a byte-identity claim nor a universal perceptual-accuracy
percentage. Highlights are capped at a reviewed q99.99 threshold and the
device exposure bounds, both journaled; infrared metering is unchanged; and
each frame's journal carries an active_exposure_authority record binding
the active solve, the guarded candidate, and the exact commanded contract,
so the receipt trail proves which numbers reached the scanner and why.
For the proven LS-5000 full-record geometry, fine-scan decoding now starts
while the raw capture is still arriving. This is an advisory fast path: the
raw capture remains the oracle, and an absent, slow, malformed, or failed
streaming sidecar falls back to the normal offline decode without interrupting
or blocking the scanner read. Set COOLSCANPY_CAPTURE_STREAMING=0 to disable
this optimization. The streaming path is covered by hardware-free tests; no
additional live-hardware claim is made for it here.
Coverage is uneven by material. Material.COLOR_NEGATIVE scans through a
direct-USB single-pass path and is implemented end to end, preview through
receipt. Material.BLACK_AND_WHITE_NEGATIVE previews and approves
correctly, but its fine-scan path routes through SANE and that route is not
yet wired into the roll batch engine; calling scan() or scan_many() on
a black-and-white roll raises NotImplementedError with a message
explaining the gap.
coolscanpy gets the raw data off the scanner. Three other projects turn it into a finished image:
digital-fauxice —
infrared dust and scratch repair. A byte-exact, from-scratch
reimplementation of Digital ICE (the Nikon/Applied Science Fiction process
that uses the IR channel to find defects and reconstruct the RGB underneath).
Validated against Nikon's own output: 68 million 16-bit values per frame,
zero mismatches. It takes the 4000 dpi RGBI main scan plus the 285 dpi
meter pass as its prepass, and produces the same repaired output Nikon
would have. An optional hybrid mode routes the worst damage (where the
exact repair leaves visible scars) to a LaMa inpainting model, disclosed
and bounded. The meter pass coolscanpy now surfaces on Frame is exactly
what fauxice's input contract expects — same physical frame, same focus,
same transport position, captured milliseconds before the fine scan.
cool-colors — C-41 color inversion. Turns the scanner-linear negative into a positive, reproducing Nikon Scan 4's CMS-off color pipeline bit-for-bit (the per-frame inversion LUT, fixed tone curve, and gamma 2.2). With a captured per-frame builder LUT, output matches Nikon Scan byte-for-byte. Without it, a principled density inversion (film-base estimation, log inversion, normalization) gets you a natural positive from any C-41 scan.
NegPy — the desktop application that ties capture, repair, and inversion together behind a GUI. It consumes coolscanpy as an optional scanner backend, digital-fauxice as an optional IR repair engine, and runs its own inversion pipeline for the final print rendering.
The pipeline in order: coolscanpy captures → fauxice repairs dust → cool-colors (or NegPy) inverts to a positive. Each step is optional and independently installable.
pip install coolscanpy
coolscanpy requires Python 3.13 or later. To use the current checkout rather than an index release, install it in editable mode:
python -m pip install -e .
The base install covers get_devices(), open(), and everything under
Device.roll(). None of that needs SANE. get_devices()/open() fall back
to direct USB enumeration when python-sane is not installed, and the
roll-feeder extension talks to the scanner over raw USB in a separate
process regardless.
SANE is needed only for the plain Device.scan() path and the vendor
Device.eject() action:
pip install "coolscanpy[scanner]"
On macOS, that build needs sane-backends' headers, and Homebrew does not put them on the default include path:
brew install sane-backends
CPPFLAGS="-I$(brew --prefix)/include" LDFLAGS="-L$(brew --prefix)/lib" pip install "coolscanpy[scanner]"
On Linux, sudo apt install libsane-dev before the plain pip install
above is usually enough.
Plain scan, the python-sane-shaped path:
import coolscanpy
dev = coolscanpy.open("ls5000")
print(dev.option_names)
print(dev["resolution"].constraint)
dev.resolution = 4000
dev.depth = 16
rgb = dev.scan() # uint16, shape (H, W, 3)
dev.close()Roll workflow:
import coolscanpy
with coolscanpy.open("ls5000") as dev:
with dev.roll(material=coolscanpy.Material.COLOR_NEGATIVE) as roll:
thumbnails = roll.preview()
for thumb in thumbnails:
if thumb.needs_approval:
roll.approve(thumb.slot)
selected = [thumb.slot for thumb in thumbnails[:36]]
for frame in roll.scan_many(selected):
print(frame.slot, frame.rgb.shape, frame.receipt.transport_smear.verdict)
# The 285 dpi RGBI meter pass, if present:
if frame.meter_rgbi is not None:
print(" prepass for fauxice:", frame.meter_rgbi.shape)
roll.eject()roll.scan_many() opens one continuous transport reservation for the whole
list of slots and yields a Frame as each completes. roll.scan(slot) is
sugar for scanning one slot. Calling roll.safe_stop() from another thread
lets the frame in flight finish normally; the next one raises
SafeStopRequested instead of starting.
For live diagnostics or acceptance runs, pass an absolute caller-owned
directory as dev.roll(attempts_root=...). Preview rasters, transport tables,
journals, and capture scratch written there survive Roll.close() for offline
verification. Omitting it retains the self-cleaning temporary default.
Tested: Nikon Super Coolscan 5000 ED (LS-5000), firmware 1.03, with an SA-21 roll feeder wired for SA-30 compatibility.
Untested: every other Coolscan model, and any roll feeder other than the SA-21/SA-30 configuration above. Platforms: the suite runs on Linux and macOS in CI. Windows is untested; the transport layer has never run there and the concurrency tests assume POSIX file-lock semantics. The code does not assume LS-5000-only behavior where the protocol is generic, but nothing beyond the one combination above has run against real film. Reports and pull requests against other bodies are welcome, and an LS-50 test is particularly wanted: its transport and optics differ from the LS-5000, and none of those differences are covered here yet.
On the tested LS-5000/SA-21, startup READ(0x8f) can return a complete
self-declared shorter frame-table envelope with the observed 022b4b
data-underrun status. coolscanpy accepts that status only when the envelope is
valid and shorter than the requested 40-slot maximum. The observed exact
37-record canonical prefix is also bound to a matching shorter preview window
and read allocation; the canonical 40-record path is unchanged. Every other
short count, changed record prefix, malformed envelope, full-length underrun,
or differently failed response still refuses before motion. The later live
0x8e index and preview independently validate roll identity and frame
addressability before any fine scan. If the live transport table has already
entered its terminal 0x81xx/0x83xx suffix, affected trailing slots remain
visible for review but are deliberately not scanner-addressable on that
insertion.
Strips shorter than a full roll work for preview and fine scanning. A preview
traversal can park a short strip at the transport end-stop, so a batch run
started right after a preview can raise RefeedRequired. Pull the strip out,
reinsert it until the feeder grips, and run the batch again. Treat that refeed
as a new registration.
The converted SA-21 can park or eject a strip after an uncharacterized idle interval. Start the intended capture promptly after feeding. A transport-index stall or refusal is a stop condition: preserve the evidence, establish the physical media state, and do not retry the same insertion.
coolscanpy is a dependency, the way NegPy already consumes python-sane or gphoto2. It does not import NegPy, and NegPy does not depend on it by default. A caller wires it in behind whatever extension seam their own application already uses for other scanner backends: open a device, run one roll to completion, close it.
SANE's coolscan3 backend is the mature, general route to these scanners:
one API across many models, a daemon ecosystem, and a working eject. NegPy
consumes it happily. coolscanpy exists for the narrower job SANE's frame
API cannot express: archival capture with evidence. The honest split:
| Capability | coolscanpy | SANE coolscan3 |
|---|---|---|
| Single-pass 4000 dpi 16-bit RGBI contract | yes, fixed protocol | partial — RGB + separate IR handling, backend-dependent |
285 dpi meter-pass surfaced per frame (Frame.meter_rgbi) |
yes | no |
| Density-calibration payloads exposed with hashes | yes | no |
| Per-frame receipt telemetry (exposure vectors, clipping, focus, transport smear) | yes | no |
| Per-frame + session journals on disk | yes | no |
| Hash-pinned capture bundle provenance | yes | no |
| Roll batch under one reservation with fingerprint identity checks | yes | no — per-frame --frame n |
| Whole-roll preview with per-slot review states | yes | no |
| Eject | delegated to SANE (coolscanpy[scanner] extra) |
yes |
| Scanner model breadth | one tested body (LS-5000/SA-30 wiring) | many Coolscan models |
| Years in production | extracted 2026 | decades |
They compose rather than compete: the direct-USB path owns capture and its evidence chain, and the optional SANE extra covers motion conveniences the capture path does not need. A live LS-5000 run requires no SANE at all.
A roll batch takes one reservation over the physical transport for its whole scan_many() call, not one per frame, and releases it exactly once on close. Requesting a safe stop never interrupts the frame currently being read; only the next one is affected.
Before the first fine scan of a batch, the roll's fingerprint (bound at the
last preview) is checked against a fresh read of the transport. If the
comparison doesn't match, FingerprintRefused is raised instead of scanning
under the wrong geometry. Separately, a slot whose transport origin was not
confidently automatic must be approved against its current thumbnail before
it can be fine-scanned; scanning an unapproved flagged slot raises
ManualReviewRequired.
Every returned frame carries transport-smear and clipping telemetry. Clipping is informational and never gates a capture. An abnormal repeated tail from a stopped transport does gate: that frame is refused rather than returned with smeared rows.
The concurrent decoder used for proven full-record captures is deliberately non-authoritative. It submits work without blocking the USB loop, has a bounded completion wait, and records its terminal state in the frame journal. Finalization consumes its derived artifact only after revalidating its schema, raw-stream binding, hash, NPY layout, and file identities; otherwise it decodes the retained raw stream offline.
There is no GUI. The RGB comes back scanner-linear and unmodified; color
inversion and print rendering belong to the application above this library
(see cool-colors for a
standalone C-41 inverter, or
NegPy for the full desktop app).
The infrared plane comes back raw as well. Turning it into a defect mask
and healing the dust it reveals is the job of
digital-fauxice, which
consumes this package's RGBI output directly — the Frame.meter_rgbi
field is the 285 dpi prepass its input contract requires.
GPL-3.0-only. The code began life on a fork branch of NegPy, marcinz606's film-negative processing application, and is republished here as a standalone package under the same license.