Hi Pär,

Great work on the code! I've got many customers in Sweden for my device and some customers referred me to this code of yours.

My device has an integrated hardware inverter and I'm using the 2nd uart of the esp12f. Therefore the uart is changed in my below yaml code:

esphome:
  name: slimmelezer-se
  platform: ESP8266
  board: d1_mini
  includes:
    - p1reader.h

wifi:
  ssid: !secret wifi_ssid
  password: !secret wifi_password

  # Enable fallback hotspot (captive portal) in case wifi connection fails
  ap:
    ssid: "slimmelezer-se"

captive_portal:

# Enable logging
logger:
  level: DEBUG
  baud_rate: 0 # disable logging over uart
  
# Enable Home Assistant API
api:

ota:

web_server:
  port: 80

uart:
  id: uart_bus
  rx_pin: D7
  baud_rate: 115200
  
sensor:
- platform: custom
  lambda: |-
    auto meter_sensor = new P1Reader(id(uart_bus));
    App.register_component(meter_sensor);
    return {
      meter_sensor->cumulativeActiveImport,
      meter_sensor->cumulativeActiveExport,
      meter_sensor->cumulativeReactiveImport,
      meter_sensor->cumulativeReactiveExport,
      meter_sensor->momentaryActiveImport,
      meter_sensor->momentaryActiveExport,
      meter_sensor->momentaryReactiveImport,
      meter_sensor->momentaryReactiveExport,
      meter_sensor->momentaryActiveImportL1,
      meter_sensor->momentaryActiveExportL1,
      meter_sensor->momentaryActiveImportL2,
      meter_sensor->momentaryActiveExportL2,
      meter_sensor->momentaryActiveImportL3,
      meter_sensor->momentaryActiveExportL3,
      meter_sensor->momentaryReactiveImportL1,
      meter_sensor->momentaryReactiveExportL1,
      meter_sensor->momentaryReactiveImportL2,
      meter_sensor->momentaryReactiveExportL2,
      meter_sensor->momentaryReactiveImportL3,
      meter_sensor->momentaryReactiveExportL3,
      meter_sensor->voltageL1,
      meter_sensor->voltageL2,
      meter_sensor->voltageL3,
      meter_sensor->currentL1,
      meter_sensor->currentL2,
      meter_sensor->currentL3
    };
  sensors:
  - name: "Cumulative Active Import"
    unit_of_measurement: kWh
    accuracy_decimals: 3
    state_class: "total_increasing"
    device_class: "energy"
  - name: "Cumulative Active Export"
    unit_of_measurement: kWh
    accuracy_decimals: 3
    state_class: "total_increasing"
    device_class: "energy"
  - name: "Cumulative Reactive Import"
    unit_of_measurement: kvarh
    accuracy_decimals: 3
  - name: "Cumulative Reactive Export"
    unit_of_measurement: kvarh
    accuracy_decimals: 3
  - name: "Momentary Active Import"
    unit_of_measurement: kW
    accuracy_decimals: 3
  - name: "Momentary Active Export"
    unit_of_measurement: kW
    accuracy_decimals: 3
  - name: "Momentary Reactive Import"
    unit_of_measurement: kvar
    accuracy_decimals: 3
  - name: "Momentary Reactive Export"
    unit_of_measurement: kvar
    accuracy_decimals: 3
  - name: "Momentary Active Import Phase 1"
    unit_of_measurement: kW
    accuracy_decimals: 3
  - name: "Momentary Active Export Phase 1"
    unit_of_measurement: kW
    accuracy_decimals: 3
  - name: "Momentary Active Import Phase 2"
    unit_of_measurement: kW
    accuracy_decimals: 3
  - name: "Momentary Active Export Phase 2"
    unit_of_measurement: kW
    accuracy_decimals: 3
  - name: "Momentary Active Import Phase 3"
    unit_of_measurement: kW
    accuracy_decimals: 3
  - name: "Momentary Active Export Phase 3"
    unit_of_measurement: kW
    accuracy_decimals: 3
  - name: "Momentary Reactive Import Phase 1"
    unit_of_measurement: kvar
    accuracy_decimals: 3
  - name: "Momentary Reactive Export Phase 1"
    unit_of_measurement: kvar
    accuracy_decimals: 3
  - name: "Momentary Reactive Import Phase 2"
    unit_of_measurement: kvar
    accuracy_decimals: 3
  - name: "Momentary Reactive Export Phase 2"
    unit_of_measurement: kvar
    accuracy_decimals: 3
  - name: "Momentary Reactive Import Phase 3"
    unit_of_measurement: kvar
    accuracy_decimals: 3
  - name: "Momentary Reactive Export Phase 3"
    unit_of_measurement: kvar
    accuracy_decimals: 3
  - name: "Voltage Phase 1"
    unit_of_measurement: V
    accuracy_decimals: 3
  - name: "Voltage Phase 2"
    unit_of_measurement: V
    accuracy_decimals: 3
  - name: "Voltage Phase 3"
    unit_of_measurement: V
    accuracy_decimals: 3
  - name: "Current Phase 1"
    unit_of_measurement: A
    accuracy_decimals: 3
  - name: "Current Phase 2"
    unit_of_measurement: A
    accuracy_decimals: 3
  - name: "Current Phase 3"
    unit_of_measurement: A
    accuracy_decimals: 3

Metadata