In der aktuellen Umsetzung wird nach dem Anstecken der SoC abgefragt. Wenn das Auslesen des SoC aus dem Fahrzeug lange dauert, liefert die Pro bei manchen Fahrzeugen (zB Enyaq) erst im zweiten Zyklus nach dem Anstecken den SoC. Die Regelung aktualisiert aber nach dem Anstecken und dann im eingestellten Intervall den SoC und dann ist der Zeitstempel vom Pro-SoC schon abgelaufen.
Deshalb wird nun immer, wenn der Zeitstempel vom Pro-SoC neuer als die letzte Abfrage ist, der SoC aktualisiert. Bei DC-Ladern wird dann kontinuierlich während der Ladung der SoC aktualisiert.
https://forum.openwb.de/viewtopic.php?p=118561#p118561