This extension is developed to extend NWB data standards to incorporate ECG recordings. CardiacSeries
, the main neurodata-type in this extension, in fact extends the base type of NWB TimeSeries and can be stored into three specific data interfaces of ECG
, HeartRate
and AuxiliaryAnalysis
. Also, the ECGRecordingGroup
is another neurodata-type in this module which extends LabMetaData
which itself extends the NWBContainer and stores descriptive meta-data recording channels information along with the electrodes implementation (ECGChannels
and ECGElectrodes
respectively as extensions of DynamicTable) and a link to another extended neurodata-type -ECGRecDevice
- which extends the type Device.
Can be installed directly from PyPI:
pip install ndx-ecg
or simply clone the repo and navigate to the root directory, then:
pip install .
A roundTrip test is runnable through pytest
from the root. The test script can be found here:
\src\pynwb\tests
The following is an example use case of ndx-ecg
with explanatory comments. First, we build up an nwbfile
and define an endpoint recording device:
from datetime import datetime
from uuid import uuid4
import numpy as np
from dateutil.tz import tzlocal
from pynwb import NWBHDF5IO, NWBFile
from hdmf.common import DynamicTable
from ndx_ecg import (
CardiacSeries,
ECG,
HeartRate,
AuxiliaryAnalysis,
ECGRecordingGroup,
ECGRecDevice,
ECGElectrodes,
ECGChannels
)
nwbfile = NWBFile(
session_description='ECG test-rec session',
identifier=str(uuid4()),
session_start_time=datetime.now(tzlocal()),
experimenter='experimenter',
lab='DCL',
institution='UKW',
experiment_description='',
session_id='',
)
# define an endpoint main recording device
main_device = nwbfile.create_device(
name='endpoint_recording_device',
description='description_of_the_ERD', # ERD: Endpoint recording device
manufacturer='manufacturer_of_the_ERD'
)
Then, we define instances of ECGElectrodes
and ECGChannels
, to represent the meta-data on the recording electrodes and also the recording channels:
'''
creating an ECG electrodes table
as a DynamicTable
'''
ecg_electrodes_table = ECGElectrodes(
description='descriptive meta-data on ECG recording electrodes'
)
# add electrodes
ecg_electrodes_table.add_row(
electrode_name='el_0',
electrode_location='right upper-chest',
electrode_info='descriptive info on el_0'
)
ecg_electrodes_table.add_row(
electrode_name='el_1',
electrode_location='left lower-chest',
electrode_info='descriptive info on el_1'
)
ecg_electrodes_table.add_row(
electrode_name='reference',
electrode_location='top of the head',
electrode_info='descriptive info on reference'
)
# adding the object of DynamicTable
nwbfile.add_acquisition(ecg_electrodes_table) # storage point for DT
'''
creating an ECG recording channels table
as a DynamicTable
'''
ecg_channels_table = ECGChannels(
description='descriptive meta-data on ECG recording channels'
)
# add channels
ecg_channels_table.add_row(
channel_name='ch_0',
channel_type='single',
involved_electrodes='el_0',
channel_info='channel info on ch_0'
)
ecg_channels_table.add_row(
channel_name='ch_1',
channel_type='differential',
involved_electrodes='el_0 and el_1',
channel_info='channel info on ch_1'
)
# adding the object of DynamicTable
nwbfile.add_acquisition(ecg_channels_table) # storage point for DT
Now, we can define an instance of ECGRecDevice
:
# define an ECGRecDevice-type device for ecg recording
ecg_device = ECGRecDevice(
name='recording_device',
description='description_of_the_ECGRD',
manufacturer='manufacturer_of_the_ECGRD',
filtering='notch-60Hz-analog',
gain='100',
offset='0',
synchronization='taken care of via ...',
endpoint_recording_device=main_device
)
# adding the object of ECGRecDevice
nwbfile.add_device(ecg_device)
And also an instance of ECGChannelsGroup
:
ecg_recording_group = ECGRecordingGroup(
name='recording_group',
group_description='a group to store electrodes and channels table, and linking to ECGRecDevice.',
electrodes=ecg_electrodes_table,
channels=ecg_channels_table,
recording_device=ecg_device
)
# adding the object of ECGChannelsGroup
nwbfile.add_lab_meta_data(ecg_recording_group) # storage point for custom LMD
#
Now, we have all the required standard arguments to genearate instances of CardiacSeries
and stroing them in our three different NWBDataInterfaces:
# storing the ECG data
dum_data_ecg = np.random.randn(20, 2)
dum_time_ecg = np.linspace(0, 10, len(dum_data_ecg))
ecg_cardiac_series = CardiacSeries(
name='ecg_raw_CS',
data=dum_data_ecg,
timestamps=dum_time_ecg,
unit='mV',
recording_group=ecg_recording_group
)
ecg_raw = ECG(
cardiac_series=[ecg_cardiac_series],
processing_description='raw acquisition'
)
Here, we built an instance of our CradiacSeries
to store a dummy raw ECG acquisition into a specified ECG
interface, and we store it as an acquisition into the nwbfile
:
# adding the raw acquisition of ECG to the nwb_file inside an 'ECG' container
nwbfile.add_acquisition(ecg_raw)
In the following, we have taken the similar approach but this time storing dummy data as processed data, into specific interfaces of HeartRate
and AuxiliaryAnalysis
, then storing it into a -to be defined- ecg_module
:
# storing the HeartRate data
dum_data_hr = np.random.randn(10, 2)
dum_time_hr = np.linspace(0, 10, len(dum_data_hr))
hr_cardiac_series = CardiacSeries(
name='heart_rate_CS',
data=dum_data_hr,
timestamps=dum_time_hr,
unit='bpm',
recording_group=ecg_recording_group
)
# defining an ecg_module to store the processed cardiac data and analysis
ecg_module = nwbfile.create_processing_module(
name='cardio_module',
description='a module to store processed cardiac data'
)
hr = HeartRate(
cardiac_series=[hr_cardiac_series],
processing_description='processed heartRate of the animal'
)
# adding the heart rate data to the nwb_file inside an 'HeartRate' container
ecg_module.add(hr)
# storing the Auxiliary data
# An example could be the concept of ceiling that is being used in the literature published by DCL@UKW
dum_data_ceil = np.random.randn(10, 2)
dum_time_ceil = np.linspace(0, 10, len(dum_data_ceil))
ceil_cardiac_series = CardiacSeries(
name='heart_rate_ceil_CS',
data=dum_data_ceil,
timestamps=dum_time_ceil,
unit='bpm',
recording_group=ecg_recording_group
)
ceil = AuxiliaryAnalysis(
cardiac_series=[ceil_cardiac_series],
processing_description='processed auxiliary analysis'
)
# adding the 'ceiling' auxiliary analysis to the nwb_file inside an 'AuxiliaryAnalysis' container
ecg_module.add(ceil)
# storing the processed heart rate: as an NWBDataInterface with the new assigned name instead of default
# An example could be the concept of HR2ceiling that is being used in the literature published by DCL@UKW
dum_data_hr2ceil = np.random.randn(10, 2)
dum_time_hr2ceil = np.linspace(0, 10, len(dum_data_hr2ceil))
hr2ceil_cardiac_series = CardiacSeries(
name='heart_rate_to_ceil_CS',
data=dum_data_hr2ceil,
timestamps=dum_time_hr2ceil,
unit='bpm',
recording_group=ecg_recording_group
)
hr2ceil = HeartRate(
name='HR2Ceil',
cardiac_series=[hr2ceil_cardiac_series],
processing_description='processed heartRate to ceiling'
)
# adding the 'HR2ceiling' processed HR to the nwb_file inside an 'HeartRate' container
ecg_module.add(hr2ceil)
Now, the nwbfile