Noticed in opensource v3.3.0.1 currently published on website links. Checked most recent opensource 3.3.0.12 binary at time of writing from github, issue also present.
Minor location issue in the PingCastle report with the Stale Object section "Verify the Default Application for Script File Execution". Under the advised solution the notes state to navigate to "Computer Configuration / Preferences / Windows Settings / Folders"
I believe this is incorrect and should in fact read "Computer Configuration / Preferences / Windows Settings / Control Panel / Folder Options"
The remdiation step also doesnt seem to correctly suggest the associated class to set when defining the filetype which appears to be mandatory if using this GPO item.
Screenshot attached for reference.
Thank you for PingCastle - quite interesting results revealed for discussion for my client!