Skip to content

CyberPower CST135UC2 supported by usbhid-ups #2786

Open
@neilwaybright

Description

@neilwaybright

CyberPower CST135UC2

upsc cyberpower1350
Init SSL without certificate database
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 20
battery.mfr.date: CPS
battery.runtime: 4875
battery.runtime.low: 300
battery.type: PbAcid
battery.voltage: 26.0
battery.voltage.nominal: 24
device.mfr: CPS
device.model: CST135UC2
device.serial: CDZNW7021381
device.type: ups
driver.name: usbhid-ups
driver.parameter.bus: 003
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 1
driver.parameter.port: auto
driver.parameter.productid: 0601
driver.parameter.synchronous: auto
driver.parameter.vendorid: 0764
driver.version: 2.8.0
driver.version.data: CyberPower HID 0.6
driver.version.internal: 0.47
driver.version.usb: libusb-1.0.26 (API: 0x1000109)
input.voltage: 117.0
input.voltage.nominal: 120
output.voltage: 117.0
ups.beeper.status: enabled
ups.delay.shutdown: 20
ups.delay.start: 30
ups.load: 10
ups.mfr: CPS
ups.model: CST135UC2
ups.productid: 0601
ups.realpower.nominal: 810
ups.serial: CDZNW7021381
ups.status: OL
ups.test.result: No test initiated
ups.timer.shutdown: -60
ups.timer.start: -60
ups.vendorid: 0764

I have been unable to remove power (plug is in a super-inconvenient place for me), but pulling the USB cable does result in a Communications failure/Communications Restored.

Manufacturer's Website (manuals are on downloads tab): https://www.cyberpowersystems.com/product/ups/battery-backup/cst135uc2/

Metadata

Metadata

Assignees

No one assigned

    Labels

    CyberPower (CPS)DDLUSBimpacts-release-2.8.0Issues reported against NUT release 2.8.0 (maybe vanilla or with minor packaging tweaks)

    Type

    No type

    Projects

    Status

    Todo

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions