Support scaling the ilimit on a per-command basis
Browse files Browse the repository at this point in the history
This makes it possible to switch between velocity and position mode
when a non-zero ilimit is configured.
  • Loading branch information
jpieper committed May 20, 2024
1 parent 022cb6a commit 0e85e45
Show file tree
Hide file tree
Showing 9 changed files with 119 additions and 53 deletions.
102 changes: 58 additions & 44 deletions docs/reference.md
Original file line number Diff line number Diff line change
Expand Up @@ -897,41 +897,49 @@ If specified and not-NaN, then the control mode will temporarily be in
the "fixed voltage" mode, regardless of the current setting of
`servo.fixed_voltage_mode`.

### 0x030 - Proportional torque ###
#### 0x02b - Ki ilimit scale ####

Mode: Read/write

When in Position mode, shrink the integral term's windup limit by the
given factor. Integral types are applied as for PWM. If unspecified,
1.0 is used.

#### 0x030 - Proportional torque ####

Mode: Read

This reports the torque contribution from the proportional term in the
PID controller.

### 0x031 - Integral torque ###
#### 0x031 - Integral torque ####

Mode: Read

This reports the torque contribution from the integral term in the
PID controller.

### 0x032 - Derivative torque ###
#### 0x032 - Derivative torque ####

Mode: Read

This reports the torque contribution from the derivative term in the
PID controller.

### 0x033 - Feedforward torque ###
#### 0x033 - Feedforward torque ####

Mode: Read

This reports the feedforward contribution in the PID controller.

### 0x034 - Total control torque ###
#### 0x034 - Total control torque ####

Mode: Read

This reports the total commanded torque from the position mode
controller. This is also reported in 0x03a.

### 0x038 - Control Position ###
#### 0x038 - Control Position ####

Mode: Read

Expand All @@ -940,7 +948,7 @@ that is valid. When velocity or acceleration limiting is enabled, the
control position will follow the desired limits to achieve the command
position.

### 0x039 - Control Velocity ###
#### 0x039 - Control Velocity ####

Mode: Read

Expand All @@ -949,32 +957,32 @@ is valid. When velocity or acceleration limiting is enabled, the
control velocity will follow the desired limits to achieve the control
position and velocity.

### 0x03a - Control Torque ###
#### 0x03a - Control Torque ####

Mode: Read

The torque commanded by the control loop. This is the same as 0x034.

### 0x03b - Position Error ###
#### 0x03b - Position Error ####

Mode: Read

The current sensed position minus the control position.

### 0x03c - Velocity Error ###
#### 0x03c - Velocity Error ####

Mode: Read

The current sensed velocity minus the control velocity.

### 0x03d - Torque Error ###
#### 0x03d - Torque Error ####

Mode: Read

The current sensed torque minus the control torque.


### 0x040 - Stay within lower bound ###
#### 0x040 - Stay within lower bound ####

Mode: Read/write

Expand All @@ -986,7 +994,7 @@ feedforward torque is applied. When outside this bound, the PID
controller is used to force the position back to the bound. If
unspecified, 0.0 is used.

### 0x041 - Stay within upper bound ###
#### 0x041 - Stay within upper bound ####

Mode: Read/write

Expand All @@ -998,108 +1006,112 @@ a feedforward torque is applied. When outside this bound, the PID
controller is used to force the position back to the bound. If
unspecified, 0.0 is used.

### 0x042 - Feedforward torque ###
#### 0x042 - Feedforward torque ####

A shadow of the 0x022 register.

### 0x043 - Kp scale ###
#### 0x043 - Kp scale ####

A shadow of the 0x023 register.

### 0x044 - Kd scale ###
#### 0x044 - Kd scale ####

A shadow of the 0x024 register.

### 0x045 - Maximum torque ###
#### 0x045 - Maximum torque ####

A shadow of the 0x025 register.

### 0x046 - Watchdog timeout ###
#### 0x046 - Watchdog timeout ####

A shadow of the 0x027 register.

### 0x050 - Encoder 0 Position ###
#### 0x047 - Ki ilimit scale ####

A shadow of the 0x02b register.

#### 0x050 - Encoder 0 Position ####

Mode: Read only

Reports the current filtered position of the encoder configured in
slot 0.

### 0x051 - Encoder 0 Velocity ###
#### 0x051 - Encoder 0 Velocity ####

Mode: Read only

Reports the current filtered velocity of the encoder configured in
slot 0.

### 0x052 - Encoder 1 Position ###
#### 0x052 - Encoder 1 Position ####

Mode: Read only

Reports the current filtered position of the encoder configured in
slot 1.

### 0x053 - Encoder 1 Velocity ###
#### 0x053 - Encoder 1 Velocity ####

Mode: Read only

Reports the current filtered velocity of the encoder configured in
slot 1.

### 0x054 - Encoder 2 Position ###
#### 0x054 - Encoder 2 Position ####

Mode: Read only

Reports the current filtered position of the encoder configured in
slot 2.

### 0x055 - Encoder 2 Velocity ###
#### 0x055 - Encoder 2 Velocity ####

Mode: Read only

Reports the current filtered velocity of the encoder configured in
slot 2.

### 0x058 - Encoder Validity ###
#### 0x058 - Encoder Validity ####

Mode: Read only

Returns a bitfield, where bit 0 indicates whether encoder 0 is active,
bit 1 indicates whether encoder 1 is active, etc.

### 0x05c - Aux1 GPIO Command ###
#### 0x05c - Aux1 GPIO Command ####

Mode: Read/write

The current output command for any GPIOs configured as an output on
aux1 as a bitfield. Not all bits may be used, as bit 0 is always for
pin 1, whether or not it is configured as a GPIO output.

### 0x05d - Aux2 GPIO Command ###
#### 0x05d - Aux2 GPIO Command ####

Mode: Read/write

The current output command for any GPIOs configured as an output on
aux2 as a bitfield. Not all bits may be used, as bit 0 is always for
pin 1, whether or not it is configured as a GPIO output.

### 0x05e - Aux1 GPIO Status ###
#### 0x05e - Aux1 GPIO Status ####

Mode: Read only

The current input value of any GPIOs configured as an input on aux1 as
a bitfield. Not all bits may be used, as bit 0 is always for pin 1,
whether or not it is configured as a GPIO input.

### 0x05f - Aux2 GPIO Status ###
#### 0x05f - Aux2 GPIO Status ####

Mode: Read only

The current input value of any GPIOs configured as an input on aux2 as
a bitfield. Not all bits may be used, as bit 0 is always for pin 1,
whether or not it is configured as a GPIO input.

### 0x060/0x064 - Aux1 Analog Inputs ###
#### 0x060/0x064 - Aux1 Analog Inputs ####

Mode: Read only

Expand All @@ -1108,7 +1120,7 @@ registers are associated with pins 1-5, regardless of whether they are
configured as an analog input. Each value is scaled as a PWM from 0
to 1.

### 0x068/0x06c - Aux2 Analog Inputs ###
#### 0x068/0x06c - Aux2 Analog Inputs ####

Mode: Read only

Expand All @@ -1117,15 +1129,15 @@ registers are associated with pins 1-5, regardless of whether they are
configured as an analog input. Each value is scaled as a PWM from 0
to 1.

### 0x070 - Millisecond Counter ###
#### 0x070 - Millisecond Counter ####

Mode: Read only

Increments once per millisecond. It wraps at the maximum value for
the queried type to the minimum value for that type. For floating
point types, it counts integers from 0 to 8388608.

### 0x071 - Clock Trim ###
#### 0x071 - Clock Trim ####

Mode: Read/write

Expand All @@ -1139,29 +1151,29 @@ microcontroller, including CAN communication. Thus setting this to a
non-zero value may prevent future CAN communications.


### 0x100 - Model Number ###
#### 0x100 - Model Number ####

Name: Model Number
Mode: Read only

This returns a 32 bit model number.

### 0x101 - Firmware Version ###
#### 0x101 - Firmware Version ####

Mode: Read only

This returns a 32 bit firmware version, encoded bytewise as
major.minor.micro. i.e. 0x010304 is version 1.3.4


### 0x102 - Register map version ###
#### 0x102 - Register map version ####

Mode: Read only

This returns a number that indicates how to interpret all registers.


### 0x110 - Multiplex ID ###
#### 0x110 - Multiplex ID ####

Name: Multiplex ID
Mode: Configurable
Expand All @@ -1170,30 +1182,30 @@ This controls the primary ID used to access the device over the
multiplex RS485 bus. It can only be between 1 and 127. (0 is
reserved as the broadcast address).

### 0x120 - 0x122 - Serial Number ###
#### 0x120 - 0x122 - Serial Number ####

Name: Serial Number
Mode: Read only

This returns a 96 bit serial number, least significant word first.


### 0x130 - Set Output Nearest ###
#### 0x130 - Set Output Nearest ####

Mode: Write only

When sent, this causes the servo to select a whole number of internal
motor rotations so that the final position is as close to the given
position as possible.

### 0x131 - Set Output Exact ###
#### 0x131 - Set Output Exact ####

Mode: Write only

When sent, the servo will force the output position to be the exact
specified value.

### 0x132 - Require Reindex ###
#### 0x132 - Require Reindex ####

Mode: Write only

Expand All @@ -1202,7 +1214,7 @@ position be re-located before control can begin. Regardless, the
position will reset to an arbitrary value consistent with the current
encoder settings.

### 0x133 - Recapture Position and Velocity ###
#### 0x133 - Recapture Position and Velocity ####

Mode: Write only

Expand All @@ -1214,7 +1226,7 @@ current applied torque is 0, either because of an in-place maximum
torque limit of zero, or because of an in-place kp and kd scale of
zero.

### 0x140 - Driver Fault 1 ###
#### 0x140 - Driver Fault 1 ####

Mode: Read only

Expand All @@ -1223,7 +1235,7 @@ for fault register 1. Up to 16 bits may be set. This will only be
non-zero if the current mode is fault (1) and the fault code is 33
(motor driver fault).

### 0x141 - Driver Fault 2 ###
#### 0x141 - Driver Fault 2 ####

Mode: Read only.

Expand Down Expand Up @@ -1347,6 +1359,8 @@ Each optional element consists of a prefix character followed by a value. Permi
constant for the duration of this command
- `d` - kd scale: the configured kd value is multiplied by this
constant for the duration of this command
- `i` - ki ilimit scale: the configured ilimit value is multiplied by
this constant for the duration of this command
- `s` - stop position: when a non-zero velocity is given, motion stops
when the control position reaches this value.
- `f` - feedforward torque in Nm
Expand Down
3 changes: 2 additions & 1 deletion fw/bldc_servo.cc
Original file line number Diff line number Diff line change
Expand Up @@ -1938,7 +1938,7 @@ class BldcServo::Impl {
PID::ApplyOptions apply_options;
apply_options.kp_scale = 0.0f;
apply_options.kd_scale = data->kd_scale;
apply_options.ki_scale = 0.0f;
apply_options.ilimit_scale = 0.0f;

ISR_DoPositionCommon(sin_cos, &zero_velocity,
apply_options, config_.timeout_max_torque_Nm,
Expand All @@ -1949,6 +1949,7 @@ class BldcServo::Impl {
PID::ApplyOptions apply_options;
apply_options.kp_scale = data->kp_scale;
apply_options.kd_scale = data->kd_scale;
apply_options.ilimit_scale = data->ilimit_scale;

ISR_DoPositionCommon(sin_cos, data, apply_options, data->max_torque_Nm,
data->feedforward_Nm, data->velocity);
Expand Down