Skip to content

Failed to get the instance tag at "EC2 Stop By Tag" #4807

@jongwooo

Description

@jongwooo

What happened:

Fault Summary:
TARGET_SELECTION_ERROR
{"errorCode":"TARGET_SELECTION_ERROR","phase":"PreChaos","reason":"failed to get the instance tag, invalid instance tag","target":"{EC2 Instance Tag: , Region: ap-northeast-2}"}

While running an AWS experiment using litmus helm v3.9.0, I encountered an error when executing the ec2-stop-by-tag. Despite providing a value for the EC2_INSTANCE_TAG field, the experiment failed because an empty string was passed to it.

cc. @namkyu1999

What you expected to happen:
I expected the ec2-stop-by-tag experiment to stop the EC2 instance based on the provided tag value.

Where can this issue be corrected? (optional)

How to reproduce it (as minimally and precisely as possible):

  1. Install Litmus using Helm with the following command:
helm install chaos litmuschaos/litmus --namespace=litmus --create-namespace --set portal.frontend.service.type=NodePort --set mongodb.image.registry=ghcr.io/zcube --set mongodb.image.repository=bitnami-compat/mongodb --set mongodb.image.tag=6.0.5
  1. Execute the ec2-stop-by-tag with a valid EC2_INSTANCE_TAG value(e.g., stack:test).
  2. Observe that the command is passed an empty string for the EC2_INSTANCE_TAG field, causing the experiment to fail.

Anything else we need to know?:

  • I have verified that the ec2-stop-by-id is working as expected, indicating that the issue is specific to the ec2-stop-by-tag.
  • I have tried modifying the manifest to enclose the tag value in double quotes (e.g., "stack:test"), but the issue persists.

Test Environment:

  • minikube v1.33.0
  • litmus helm v3.9.0

Metadata