Closed
Description
Original report (archived issue) by Shaun Johnstone (Bitbucket: shjohnst, GitHub: shjohnst).
As per pull request #11, there is a bug where the 'extra clock tick' that can be inserted just before a break in a ramp* may be shortened incorrectly (and thus tick faster than the allowed clock_limit
rate of an attached ClockLine
) due to the quantisation of the pseudoclock.
EDIT: This was reported by @philipstarkey (@shjohnst was just logged into the PC)
* The break in ramps is a result of labscript automatically splitting ramps when another output needs to be updated during the middle of a ramp