inSCADA Modbus TCP/UDP Client is a desktop application used to connect, monitor, and interact with Modbus TCP/UDP devices. It supports reading and writing coils and registers, managing data blocks, and visualizing real-time data.
This application is designed as click-to-run on Windows. No installation is required. After downloading, simply run: ins-mod-cli.exe
You need at least version 11 of OpenJDK and OpenJFX to run the application.
sudo apt-get update
sudo apt-get upgrade
sudo apt install openjdk-11-jre
sudo apt install openjfxjava --module-path /usr/share/openjfx/lib --add-modules javafx.controls,javafx.fxml -jar ins-mod-cli.jarAfter starting the application, configure the settings according to your slave device. If your settings are true you should be able to establish a successful connection.
- Connection Type: Select TCP or UDP.
- IP Address: Enter the server (slave) device IP.
- Port: Enter the device port (Default: 502).
- Unit Address: Enter the Modbus Slave ID (Unit ID).
- Timeout: Enter the timeout in ms.
- Scan Time: Enter the scan time in ms.
- Start / Stop: Once started, the application checks connection status every 2 seconds.
Define Data Blocks first, then add individual Tags within them.
- Name: Must be unique; used as a unique identifier.
- Start Address Ranges:
- Coil: 1 – 9999
- Discrete Input: 10000 – 19999
- Holding Register: 40000 – 49999
- Input Register: 30000 – 39999
Every Data Block has its own Tags. You must define a Data Block before you add any tag.
- Name: Like Data Block names, Tag names must be defined and unique.
- Type: Select the data type you wish to read or write (e.g., Integer, Float, Boolean).
- Address: Must be within the range of the parent Data Block.
- Example: If the Data Block Start Address is
1and Amount is10, the valid Tag Address range is1 – 11.
- Example: If the Data Block Start Address is
- Byte / Word Swap: Toggle these fields based on the required endianness of your device.
- Setting Values: You can modify a tag's value by double-clicking the specific tag in the table to open the Set Value tab.
- Chart: Select one or more tags (use
CTRLfor multi-select), Right-Click, and choose Chart.- The chart displays values vs. time.
- Hover over points to see specific data.
- Click the legend to filter specific tags.
Access specialized Modbus functions via the Menu Bar:
- Coils / Discrete Inputs: Read or write multiple bits.
- Holding / Input Registers: Read and write registers.
- Mask Write Register: Bitwise AND/OR operations on Holding Registers.
- Read / Write Register: Simultaneous operations in a single request.
Monitor application operations, requests, and errors in the Log section.
- INFO (Blue): General information.
- ERROR (Red): Communication or system errors.
- WARNING (Yellow): Non-critical alerts.
- Export: Save logs as a .txt file for external troubleshooting.
Use the File menu to manage your setup:
- Save Config: Export settings as a .json file.
- Load Config: Import a previously saved .json configuration.
- Exit: Closes the application safely.
This project is licensed under the Apache License 2.0.