Modbus TCP/UDP Client - inSCADA

inSCADA Modbus TCP/UDP Client is a desktop application used to connect, monitor, and interact with Modbus TCP/UDP devices. It supports reading and writing coils and registers, managing data blocks, and visualizing real-time data.

ins-mod-cli


📑 Table of Contents


1. Setup

1.1 Setup for Windows

This application is designed as click-to-run on Windows. No installation is required. After downloading, simply run: ins-mod-cli.exe

1.2 Setup for Ubuntu

You need at least version 11 of OpenJDK and OpenJFX to run the application.

1.2.1 Install Dependencies

sudo apt-get update
sudo apt-get upgrade
sudo apt install openjdk-11-jre
sudo apt install openjfx

1.2.2 Run Application

java --module-path /usr/share/openjfx/lib --add-modules javafx.controls,javafx.fxml -jar ins-mod-cli.jar

2. Application

2.1 Connection Settings

After starting the application, configure the settings according to your slave device. If your settings are true you should be able to establish a successful connection.

conn-settings

  • Connection Type: Select TCP or UDP.
  • IP Address: Enter the server (slave) device IP.
  • Port: Enter the device port (Default: 502).
  • Unit Address: Enter the Modbus Slave ID (Unit ID).
  • Timeout: Enter the timeout in ms.
  • Scan Time: Enter the scan time in ms.
  • Start / Stop: Once started, the application checks connection status every 2 seconds.

2.2 Data Block & Tag Settings

Define Data Blocks first, then add individual Tags within them.

data-block-and-tags

2.2.1 Data Blocks

data-block

  • Name: Must be unique; used as a unique identifier.
  • Start Address Ranges:
    • Coil: 1 – 9999
    • Discrete Input: 10000 – 19999
    • Holding Register: 40000 – 49999
    • Input Register: 30000 – 39999

2.2.2 Tags

Every Data Block has its own Tags. You must define a Data Block before you add any tag.

tags

  • Name: Like Data Block names, Tag names must be defined and unique.
  • Type: Select the data type you wish to read or write (e.g., Integer, Float, Boolean).
  • Address: Must be within the range of the parent Data Block.
    • Example: If the Data Block Start Address is 1 and Amount is 10, the valid Tag Address range is 1 – 11.
  • Byte / Word Swap: Toggle these fields based on the required endianness of your device.
  • Setting Values: You can modify a tag's value by double-clicking the specific tag in the table to open the Set Value tab.
  • Chart: Select one or more tags (use CTRL for multi-select), Right-Click, and choose Chart.
    • The chart displays values vs. time.
    • Hover over points to see specific data.
    • Click the legend to filter specific tags.

chart

tag-chart

tag-chart-single


2.3 Using Functions

Access specialized Modbus functions via the Menu Bar:

funcs

  • Coils / Discrete Inputs: Read or write multiple bits.
  • Holding / Input Registers: Read and write registers.
  • Mask Write Register: Bitwise AND/OR operations on Holding Registers.
  • Read / Write Register: Simultaneous operations in a single request.

2.4 Logs

Monitor application operations, requests, and errors in the Log section.

logs

  • INFO (Blue): General information.
  • ERROR (Red): Communication or system errors.
  • WARNING (Yellow): Non-critical alerts.
  • Export: Save logs as a .txt file for external troubleshooting.

2.5 Save / Load

Use the File menu to manage your setup:

save-load

  • Save Config: Export settings as a .json file.
  • Load Config: Import a previously saved .json configuration.
  • Exit: Closes the application safely.

3. License

This project is licensed under the Apache License 2.0.