feat: Modbus support multiple slaves (gateway feature) #9279

Merged
merged 21 commits into from
Dec 2, 2021
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
Show all changes
21 commits
Select commit Hold shift + click to select a range
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
194 changes: 184 additions & 10 deletions plugins/inputs/modbus/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -3,7 +3,7 @@
The Modbus plugin collects Discrete Inputs, Coils, Input Registers and Holding
Registers via Modbus TCP or Modbus RTU/ASCII.

## Configuration
## Example configuration

```toml
[[inputs.modbus]]
Expand Down Expand Up @@ -46,6 +46,13 @@ Registers via Modbus TCP or Modbus RTU/ASCII.
## Note: You have to enable telegraf's debug mode to see those messages!
# debug_connection = false

## Define the configuration schema
## |---register -- define fields per register type in the original style (only supports one slave ID)
## |---request -- define fields on a requests base
configuration_type = "register"

## --- "register" configuration style ---

## Measurements
##

Expand Down Expand Up @@ -74,10 +81,11 @@ Registers via Modbus TCP or Modbus RTU/ASCII.
## |---BA, DCBA - Little Endian
## |---BADC - Mid-Big Endian
## |---CDAB - Mid-Little Endian
## data_type - INT16, UINT16, INT32, UINT32, INT64, UINT64, FLOAT32-IEEE, FLOAT64-IEEE (the IEEE 754 binary representation)
## FLOAT32 (deprecated), FIXED, UFIXED (fixed-point representation on input)
## scale - the final numeric variable representation
## address - variable address
## data_type - INT16, UINT16, INT32, UINT32, INT64, UINT64,
## FLOAT32-IEEE, FLOAT64-IEEE (the IEEE 754 binary representation)
## FLOAT32, FIXED, UFIXED (fixed-point representation on input)
## scale - the final numeric variable representation
## address - variable address

holding_registers = [
{ name = "power_factor", byte_order = "AB", data_type = "FIXED", scale=0.01, address = [8]},
Expand All @@ -93,6 +101,86 @@ Registers via Modbus TCP or Modbus RTU/ASCII.
{ name = "pump1_speed", byte_order = "ABCD", data_type = "INT32", scale=1.0, address = [3,4]},
]

## --- "request" configuration style ---

## Per request definition
##

## Define a request sent to the device
## Multiple of those requests can be defined. Data will be collated into metrics at the end of data collection.
[[inputs.modbus.request]]
## ID of the modbus slave device to query.
## If you need to query multiple slave-devices, create several "request" definitions.
slave_id = 1

## Byte order of the data.
## |---ABCD -- Big Endian (Motorola)
## |---DCBA -- Little Endian (Intel)
## |---BADC -- Big Endian with byte swap
## |---CDAB -- Little Endian with byte swap
byte_order = "ABCD"

## Type of the register for the request
## Can be "coil", "discrete", "holding" or "input"
register = "coil"

## Name of the measurement.
## Can be overriden by the individual field definitions. Defaults to "modbus"
# measurement = "modbus"

## Field definitions
## Analog Variables, Input Registers and Holding Registers
## address - address of the register to query. For coil and discrete inputs this is the bit address.
## name *1 - field name
## type *1,2 - type of the modbus field, can be INT16, UINT16, INT32, UINT32, INT64, UINT64 and
## FLOAT32, FLOAT64 (IEEE 754 binary representation)
## scale *1,2 - (optional) factor to scale the variable with
## output *1,2 - (optional) type of resulting field, can be INT64, UINT64 or FLOAT64. Defaults to FLOAT64 if
## "scale" is provided and to the input "type" class otherwise (i.e. INT* -> INT64, etc).
## measurement *1 - (optional) measurement name, defaults to the setting of the request
## omit - (optional) omit this field. Useful to leave out single values when querying many registers
## with a single request. Defaults to "false".
##
## *1: Those fields are ignored if field is omitted ("omit"=true)
##
## *2: Thise fields are ignored for both "coil" and "discrete"-input type of registers. For those register types
## the fields are output as zero or one in UINT64 format by default.

## Coil / discrete input example
fields = [
{ address=0, name="motor1_run"},
{ address=1, name="jog", measurement="motor"},
{ address=2, name="motor1_stop", omit=true},
{ address=3, name="motor1_overheating"},
]

[[inputs.modbus.request]]
## Holding example
## All of those examples will result in FLOAT64 field outputs
slave_id = 1
byte_order = "DCBA"
register = "holding"
fields = [
{ address=0, name="voltage", type="INT16", scale=0.1 },
{ address=1, name="current", type="INT32", scale=0.001 },
{ address=3, name="power", type="UINT32", omit=true },
{ address=5, name="energy", type="FLOAT32", scale=0.001, measurement="W" },
{ address=7, name="frequency", type="UINT32", scale=0.1 },
{ address=8, name="power_factor", type="INT64", scale=0.01 },
]

[[inputs.modbus.request]]
## Input example with type conversions
slave_id = 1
byte_order = "ABCD"
register = "input"
fields = [
{ address=0, name="rpm", type="INT16" }, # will result in INT64 field
{ address=1, name="temperature", type="INT16", scale=0.1 }, # will result in FLOAT64 field
{ address=2, name="force", type="INT32", output="FLOAT64" }, # will result in FLOAT64 field
{ address=4, name="hours", type="UINT32" }, # will result in UIN64 field
]

## Enable workarounds required by some devices to work correctly
# [inputs.modbus.workarounds]
## Pause between read requests sent to the device. This might be necessary for (slow) serial devices.
Expand All @@ -109,12 +197,27 @@ You can debug Modbus connection issues by enabling `debug_connection`. To see th

Please use `pause_between_requests` with care. Especially make sure that the total gather time, including the pause(s), does not exceed the configured collection interval. Note, that pauses add up if multiple requests are sent!

## Metrics
## Configuration styles

The modbus plugin supports multiple configuration styles that can be set using the `configuration_type` setting. The different styles are described below. Please note that styles cannot be mixed, i.e. only the settings belonging to the configured `configuration_type` are used for constructing _modbus_ requests and creation of metrics.

Directly jump to the styles:

- [original / register plugin style](#register-configuration-style)
- [per-request style](#request-configuration-style)

---

### `register` configuration style

This is the original style used by this plugin. It allows a per-register configuration for a single slave-device.

#### Metrics

Metric are custom and configured using the `discrete_inputs`, `coils`,
`holding_register` and `input_registers` options.

## Usage of `data_type`
#### Usage of `data_type`

The field `data_type` defines the representation of the data value on input from the modbus registers.
The input values are then converted from the given `data_type` to a type that is apropriate when
Expand All @@ -123,16 +226,16 @@ integer or floating-point-number. The size of the output type is assumed to be l
for all supported input types. The mapping from the input type to the output type is fixed
and cannot be configured.

### Integers: `INT16`, `UINT16`, `INT32`, `UINT32`, `INT64`, `UINT64`
##### Integers: `INT16`, `UINT16`, `INT32`, `UINT32`, `INT64`, `UINT64`

These types are used for integer input values. Select the one that matches your modbus data source.

### Floating Point: `FLOAT32-IEEE`, `FLOAT64-IEEE`
##### Floating Point: `FLOAT32-IEEE`, `FLOAT64-IEEE`

Use these types if your modbus registers contain a value that is encoded in this format. These types
always include the sign and therefore there exists no variant.

### Fixed Point: `FIXED`, `UFIXED` (`FLOAT32`)
##### Fixed Point: `FIXED`, `UFIXED` (`FLOAT32`)

These types are handled as an integer type on input, but are converted to floating point representation
for further processing (e.g. scaling). Use one of these types when the input value is a decimal fixed point
Expand All @@ -149,6 +252,76 @@ with N decimal places'.
(FLOAT32 is deprecated and should not be used any more. UFIXED provides the same conversion
from unsigned values).

---

### `request` configuration style

This sytle can be used to specify the modbus requests directly. It allows to specify multiple `[[inputs.modbus.request]]` sections including multiple slave-devices. This way, _modbus_ gateway devices can be queried. Please not that _requests_ might be split for non-consecutive addresses. If you want to avoid this behavior please add _fields_ with the `omit` flag set filling the gaps between addresses.

#### Slave device

You can use the `slave_id` setting to specify the ID of the slave device to query. It should be specified for each request and defaults to zero otherwise. Please note, only one `slave_id` can be specified for a request.

#### Byte order of the register

The `byte_order` setting specifies the byte- and word-order of the registers. It can be set to `ABCD` for _big endian (Motorola)_ or `DCBA` for _little endian (Intel)_ format as well as `BADC` and `CDAB` for _big endian_ or _little endian_ with _byte swap_.

#### Register type

The `register` setting specifies the modbus register-set to query and can be set to `coil`, `discrete`, `holding` or `input`.

#### Per-request measurement setting

You can specify the name of the measurement for the following field definitions using the `measurement` setting. If the setting is omitted `modbus` is used. Furthermore, the measurement value can be overridden by each field individually.

#### Field definitions

Each `request` can contain a list of fields to collect from the modbus device.

##### address

A field is identified by an `address` that reflects the modbus register address. You can usually find the address values for the different datapoints in the datasheet of your modbus device. This is a mandatory setting.

For _coil_ and _discrete input_ registers this setting specifies the __bit__ containing the value of the field.

##### name

Using the `name` setting you can specify the field-name in the metric as output by the plugin. This setting is ignored if the field's `omit` is set to `true` and can be omitted in this case.

__Please note:__ There cannot be multiple fields with the same `name` in one metric identified by `measurement`, `slave_id` and `register`.

##### register datatype

The `register` setting specifies the datatype of the modbus register and can be set to `INT16`, `UINT16`, `INT32`, `UINT32`, `INT64` or `UINT64` for integer types or `FLOAT32` and `FLOAT64` for IEEE 754 binary representations of floating point values. Usually the datatype of the register is listed in the datasheet of your modbus device in relation to the `address` described above.

This setting is ignored if the field's `omit` is set to `true` or if the `register` type is a bit-type (`coil` or `discrete`) and can be omitted in these cases.

##### scaling

You can use the `scale` setting to scale the register values, e.g. if the register contains a fix-point values in `UINT32` format with two decimal places for example. To convert the read register value to the actual value you can set the `scale=0.01`. The scale is used as a factor as `field_value * scale`.

This setting is ignored if the field's `omit` is set to `true` or if the `register` type is a bit-type (`coil` or `discrete`) and can be omitted in these cases.

__Please note:__ The resulting field-type will be set to `FLOAT64` if no output format is specified.

##### output datatype

Using the `output` setting you might explicitly specify the output field-datatype. The `output` type can be `INT64`, `UINT64` or `FLOAT64`. If not set explicitly, the output type is guessed as follows: If `scale` is set to a non-zero value, the output type is `FLOAT64`. Otherwise, the output type corresponds to the register datatype _class_, i.e. `INT*` will result in `INT64`, `UINT*` in `UINT64` and `FLOAT*` in `FLOAT64`.

This setting is ignored if the field's `omit` is set to `true` or if the `register` type is a bit-type (`coil` or `discrete`) and can be omitted in these cases. For `coil` and `discrete` registers the field-value is output as zero or one in `UINT16` format.

#### per-field measurement setting

The `measurement` setting can be used to override the measurement name on a per-field basis. This might be useful if you can to split the fields in one request to multiple measurements. If not specified, the value specified in the [`request` section](#per-request-measurement-setting) or, if also omitted, `modbus` is used.

This setting is ignored if the field's `omit` is set to `true` and can be omitted in this case.

#### omitting a field

When specifying `omit=true`, the corresponding field will be ignored when collecting the metric but is taken into account when constructing the modbus requests. This way, you can fill "holes" in the addresses to construct consecutive address ranges resulting in a single request. Using a single modbus request can be beneficial as the values are all collected at the same point in time.

---

## Trouble shooting

### Strange data
Expand All @@ -165,6 +338,7 @@ In case you get an `exception '2' (illegal data address)` error you might try to
In case you see strange values, the `byte_order` might be off. You can either probe all combinations (`ABCD`, `CDBA`, `BADC` or `DCBA`) or you set `byte_order="ABCD" data_type="UINT32"` and use the resulting value(s) in an online converter like [this](https://www.scadacore.com/tools/programming-calculators/online-hex-converter/). This makes especially sense if you don't want to mess with the device, deal with 64-bit values and/or don't know the `data_type` of your register (e.g. fix-point floating values vs. IEEE floating point).

If your data still looks corrupted, please post your configuration, error message and/or the output of `byte_order="ABCD" data_type="UINT32"` to one of the telegraf support channels (forum, slack or as issue).
If nothing helps, please post your configuration, error message and/or the output of `byte_order="ABCD" data_type="UINT32"` to one of the telegraf support channels (forum, slack or as issue).

### Workarounds

Expand Down
5 changes: 3 additions & 2 deletions plugins/inputs/modbus/configuration.go
Original file line number Diff line number Diff line change
Expand Up @@ -14,6 +14,7 @@ const (
type Configuration interface {
Check() error
Process() (map[byte]requestSet, error)
SampleConfigPart() string
}

func removeDuplicates(elements []uint16) []uint16 {
Expand All @@ -35,7 +36,7 @@ func normalizeInputDatatype(dataType string) (string, error) {
case "INT16", "UINT16", "INT32", "UINT32", "INT64", "UINT64", "FLOAT32", "FLOAT64":
return dataType, nil
}
return "unknown", fmt.Errorf("unknown type %q", dataType)
return "unknown", fmt.Errorf("unknown input type %q", dataType)
}

func normalizeOutputDatatype(dataType string) (string, error) {
Expand All @@ -45,7 +46,7 @@ func normalizeOutputDatatype(dataType string) (string, error) {
case "INT64", "UINT64", "FLOAT64":
return dataType, nil
}
return "unknown", fmt.Errorf("unknown type %q", dataType)
return "unknown", fmt.Errorf("unknown output type %q", dataType)
}

func normalizeByteOrder(byteOrder string) (string, error) {
Expand Down
Loading