climate.generic_thermostat initial_operation_mode #4020

Merged
merged 2 commits into from
Dec 9, 2017
Merged
Changes from 1 commit
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
Next Next commit
climate.generic_thermostat initial_operation_mode
  • Loading branch information
ziotibia81 authored Nov 20, 2017
commit 0c13356fecb0fb9061a1f635c67c0c8cc8d6b09e
2 changes: 2 additions & 0 deletions source/_components/climate.generic_thermostat.markdown
Original file line number Diff line number Diff line change
Expand Up @@ -38,6 +38,7 @@ Configuration variables:
- **cold_tolerance** (*Optional*): Set a minimum amount of difference between the temperature read by the sensor specified in the *target_sensor* option and the target temperature that must change prior to being switched on. For example, if the target temperature is 25 and the tolerance is 0.5 the heater will start when the sensor equals or goes below 24.5.
- **hot_tolerance** (*Optional*): Set a minimum amount of difference between the temperature read by the sensor specified in the *target_sensor* option and the target temperature that must change prior to being switched off. For example, if the target temperature is 25 and the tolerance is 0.5 the heater will stop when the sensor equals or goes above 25.5.
- **keep_alive** (*Optional*): Set a keep-alive interval. If set, the switch specified in the *heater* option will be triggered every time the interval elapses. Use with heaters and A/C units that shut off if they don't receive a signal from their remote for a while.
- **initial_operation_mode** (*Optional*): Set the initial operation mode. Valid values are `off` or `auto`. Value has to be double quoted.

A full configuration example looks like the one below. `min_cycle_duration` and `keep_alive` must contain at least one of the following entries: `days:`, `hours:`, `minutes:`, `seconds:` or `milliseconds:`.

Expand All @@ -57,4 +58,5 @@ climate:
seconds: 5
keep_alive:
minutes: 3
initial_operation_mode: "off"
```