@EPrade

Problem:
The loss coefficient parameter in the components heat exchanger and pressure control cannot be used without a diameter and the diameter is not an input parameter at the moment.

Possible solutions:

For pressure Control:

Remove loss coefficient for pressure control, since the pressure is set within that component anyway.

For heat exchangers:

Replace the loss coefficient with an input parameter for a fixed pressure loss e.g. "fixed pressure loss[bar]", so that the user can directly input the pressure loss the heat exchanger should induce.