You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
The expected value check can be used to check pull down/pull up signals.
The opposite logic value should still have a path, which can cause a possible leak (LEAK?) error.
If there is a high resistance to the sim level and a matching expected sim level check, then don't flag a possible leak error.
The text was updated successfully, but these errors were encountered:
d-m-bailey
changed the title
Don't high resistance flag possible leaks to expected sim values.
Don't flag high resistance possible leaks to expected sim values.
Feb 9, 2024
The expected value check can be used to check pull down/pull up signals.
The opposite logic value should still have a path, which can cause a possible leak (LEAK?) error.
If there is a high resistance to the sim level and a matching expected sim level check, then don't flag a possible leak error.
The text was updated successfully, but these errors were encountered: