Skip to content

Solvent gets unbound in MD during QCG run #471

@codecollider

Description

@codecollider

Hi,

I'm currently testing QCG and because of some issues I'm testing the examples first. Specifically example 4 from: https://crest-lab.github.io/crest-docs/page/examples/qcg/example_4.html

I downloaded the coord files and ran it with crest pentanol.xyz --qcg benzene.coord --nsolv 25 --T 12 --gsolv --nclus 4 --fscal 0.65 --gbsa benzene

What looks strange to me is, that during the MD (folder tmp_MTD) the solvent (here benzene) is leaving the solute like no repulsive potential is present. Is this correct behaviour? I guess nci is used without explicitly turning it on, right?

I'm using CREST Version 3.0.2, Fri, 27 September 16:49:34, 09/27/2024 commit` (a71e303) and xTB 6.6.1.

I added the data from the (still running) simulation.