Fix ganglion firmware v2 packet ordering #664
Merged
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
There was a problem with the packet ordering for the Ganglion firmware v2 decompression. In this firmware, a raw packet is sent every 100Hz to "reset" the delta compression. The previous implementation wrote this raw packet in the wrong order and left the sample package where it should have been unchanged. This didn't change the data stream much (it just wrote the same sample twice), but it would cause the same package index to be written twice. This is an issue for downstream clients that use the package index to check if samples have been lost over the bluetooth connection.