fix PrismaClientInitializationError #326
Merged
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
api-1 | PrismaClientInitializationError: Prisma Client could not locate the Query Engine for runtime "linux-arm64-openssl-3.0.x".
api-1 |
api-1 | This happened because Prisma Client was generated for "linux-arm64-openssl-1.1.x", but the actual deployment required "linux-arm64-openssl-3.0.x".
api-1 | Add "linux-arm64-openssl-3.0.x" to
binaryTargets
in the "schema.prisma" file and runprisma generate
after saving it:api-1 |
api-1 | generator client {
api-1 | provider = "prisma-client-js"
api-1 | binaryTargets = ["native", "debian-openssl-3.0.x", "linux-arm64-openssl-3.0.x"]
api-1 | }