dbus-power-watchdog

Venus OS service that discovers and manages Hughes Power Watchdog surge protectors via Bluetooth Low Energy.

Overview

A single-process Venus OS service that scans BLE for Power Watchdog devices and presents them as dimmable switches in the Venus OS switches pane. When a device is enabled, the service connects to it via BLE and publishes L1/L2 AC voltage, current, power, energy, and frequency to the Venus OS D-Bus.

Only one Power Watchdog device may be active at a time. Enabling a device automatically disables any previously active one. Each device's switch includes a slider to control the polling interval (100ms-10000ms).

Supports role assignment as a grid meter, generator meter, or PV inverter meter. Settings (role, custom name, position, polling interval) are persisted via com.victronenergy.settings and survive reboots.

Supports both 30A (single-line) and 50A (dual-line L1+L2) Power Watchdog models, including gen1 (BT-only) and gen2 (WiFi+BT) hardware.

Cerbo GX Screenshots

Overview dashboard — Power Watchdog reporting as the grid meter (178W across L1+L2), with AC Loads, Essential Loads, DC Loads, battery, and inverter status all visible:

Cerbo GX overview dashboard

Power Watchdog device detail — per-phase AC voltage, current, power, and cumulative energy totals:

Power Watchdog device detail

Switch panel — Discovery toggle, system setting overrides, and the per-device polling interval slider (shown at 500ms):

Power Watchdog switch panel

Architecture

dbus-power-watchdog.py          (single process — discovery + BLE + grid service)
  ├─ Registers as com.victronenergy.switch.power_watchdog
  ├─ Discovery toggle in Venus OS switches pane
  ├─ Per-device dimmable switches (on/off + polling interval slider)
  ├─ "Report AC Input Loads" system toggle (HasAcInLoads)
  ├─ "Use Inverter Metering" system toggle (RunWithoutGridMeter)
  └─ When a device is enabled:
       ├─ Resolves the device (BlueZ cache first, then a scan)
       ├─ Connects via bleak-retry-connector, routed underneath by
       │  bleak-connection-manager v2 (the "bleak catcher")
       │    ├─ bleak.BleakClient rebound process wide at startup
       │    ├─ Claim-aware adapter selection (/run/bt-claims, bt-claims
       │    │  convention — other BLE services on the GX see our use)
       │    ├─ Per-adapter link slots (ble_link_caps) and failure-driven
       │    │  rotation for pinned devices
       │    ├─ Post-connect validation: a link whose GATT is not a Power
       │    │  Watchdog is torn down and retried on the next radio
       │    └─ habluetooth connection-parameter tuning over the mgmt socket
       ├─ NotificationWatchdog tears the session down on a silent link
       └─ Registers com.victronenergy.grid.power_watchdog_{mac_id}

Only one device may be active at a time. Enabling a second device automatically disables the first. power_watchdog_device.py is retained as a standalone fallback for manual use.

Sensors

  • Line 1: Voltage (V), Current (A), Power (W), Energy (kWh), Frequency (Hz)
  • Line 2: Voltage (V), Current (A), Power (W), Energy (kWh), Frequency (Hz)
  • Combined: Total Power (W), Total Current (A), Average Voltage (V), Total Energy (kWh)
  • Error Code: 0-9 (see Hughes documentation)

D-Bus Paths

Each enabled device registers as com.victronenergy.grid.power_watchdog_{mac} (or genset/pvinverter depending on role).

Path Description
/Role Current role (writable: grid, pvinverter, genset)
/AllowedRoles Available roles
/Position PV inverter position (writable, only used when role=pvinverter)
/CustomName User-defined name (writable, persisted)
/NrOfPhases Number of phases (1 or 2, auto-detected)
/RefreshTime Measurement interval in milliseconds
/Ac/L1/* Line 1 measurements
/Ac/L2/* Line 2 measurements (50A models)
/Ac/Power Total AC power (W)
/ErrorCode Current error code

Device Discovery

The service scans BLE for two naming patterns:

Generation BLE Name Pattern Example
Gen2 (WiFi+BT) WD_{type}_{serial} WD_E7_aabbccddeeff
Gen1 (BT-only) PM{S|D}... (19 chars) PMD... (50A), PMS... (30A)

Discovery scans use plain BleakScanner on the configured adapter. Set ble_wrap_scanner = true to route scans through the connection manager's adapter-bound, claiming scanner instead.

Requirements

  • Venus OS >= 3.x (Cerbo GX or similar)
  • Hughes Power Watchdog with Bluetooth (gen1 or gen2)
  • BLE adapter available on the GX device (one or two HCI adapters)
  • Python 3 (included with Venus OS)
  • Git (for cloning; the installer will install it via opkg if needed)

The entire BLE stack comes from the shared install at /data/bcm — one bleak-connection-manager checkout serving every BLE service on the GX. install.sh converges that checkout (clone, or fetch + --ff-only) and runs its installer; the service then puts that checkout on its own sys.path at start (ble_stack.py, a verbatim copy of the fleet's reference consumer contract) and imports the connection manager before bleak. Nothing about how it was launched decides the stack: service/run is plain python3. This is what keeps every BLE service on the box speaking one version of the claims convention. Two config keys govern it, ble_connection_manager_dir (where the install is; empty means never look) and ble_force_start_notify (the fleet's BlueZ StartNotify policy, stated per consumer).

This repo vendors no part of that stack, and pins no version of it. A private pin is how one service drifts onto a different convention than the rest of the fleet — and it also let this repo's tests run bleak 2.1.1 while production ran 3.0.2. The shared install failing is therefore fatal, not a degradation: nothing else provides bleak.

Submodule Purpose
velib_python Victron D-Bus service helper library (not served by the shared install)

Running the tests

The suite needs a bleak of its own, pinned to what the shared checkout serves so it cannot drift from production:

python3 -m venv .venv && .venv/bin/python -m pip install -r requirements-dev.txt
.venv/bin/python -m pytest -q

bleak-connection-manager is deliberately absent there — the tests stub it, and its absence exercises the documented "connect uncoordinated" path.

Installation

One-Line Remote Install

ssh root@<cerbo-ip> "curl -fsSL https://raw.githubusercontent.com/TechBlueprints/dbus-power-watchdog/main/install.sh | bash"

Manual Installation

ssh root@<cerbo-ip>
cd /data/apps
git clone --recurse-submodules https://github.com/TechBlueprints/dbus-power-watchdog.git
cd dbus-power-watchdog
bash enable.sh

If you cloned without --recurse-submodules, initialize them manually:

git submodule update --init --recursive

Usage

  1. Install the service (see above)
  2. Open the Venus OS Remote Console or VRM
  3. Navigate to Settings > I/O > Switches (or the device list)
  4. Find "Power Watchdog Manager" and enable Device Discovery
  5. Discovered Power Watchdog devices will appear as dimmable switches
  6. Enable a device to start reading AC data (only one may be active at a time)
  7. Use the slider to adjust the polling interval (100ms-10000ms)
  8. The device will appear as a grid meter (or genset/pvinverter after role change)

System Settings (GUI Controls)

The Power Watchdog Manager pane exposes additional controls beyond the discovery toggle. Each discovered device has its own polling interval slider (see below), and two system-level toggles affect how Venus OS interprets your system topology.

Per-Device Polling Interval

Persistent setting: /Settings/Devices/power_watchdog/Device_{mac_id}/PollIntervalMs Default: 5000ms (slider position 50)

Each discovered Power Watchdog device appears as a dimmable switch (Type 2) in the Venus OS switches pane. The switch has two controls:

  • State (on/off): Enables or disables the BLE connection for this device
  • Dimming (slider 1-100): Controls the polling interval

Each slider step is 100ms:

Slider Interval Notes
1 100ms Fastest; highest BLE traffic
50 5000ms Default; good balance of responsiveness and efficiency
100 10000ms Slowest; lowest BLE overhead

The switch name label updates in real-time to show the current interval, e.g. WD_E7_aabbccddeeff (5000ms).

Slider changes are debounced by 5 seconds before taking effect. This prevents rapid GUI dragging from causing excessive BLE rescheduling. The interval is persisted per device and restored on reboot.

Report AC Input Loads (HasAcInLoads)

D-Bus setting: /Settings/SystemSetup/HasAcInLoads Default: ON (1)

Tells Venus OS that there are loads wired between the grid meter and the inverter's AC input. When enabled, dbus-systemcalc-py calculates /Ac/ConsumptionOnInput as the difference between the grid meter reading and the inverter AC-in reading, and publishes it separately from /Ac/ConsumptionOnOutput.

Setting Cerbo GUI VRM Portal
ON Shows separate "AC Loads" (input-side) and "Essential Loads" (output-side) tiles "AC Loads" tile shows input-side consumption instead of "-"
OFF Shows a single "AC Loads" tile using total /Ac/Consumption "AC Loads" tile shows "-" (blank)

Recommendation: Leave ON if you have any loads between the Power Watchdog and the inverter (e.g., shore power outlets, HVAC). Turn OFF for the simplest display if the Power Watchdog is wired directly to the inverter with nothing in between.

Use Inverter Metering (RunWithoutGridMeter)

D-Bus setting: /Settings/CGwacs/RunWithoutGridMeter Default: OFF (0)

Controls whether Venus OS uses the external grid meter (Power Watchdog) or the inverter's internal metering for system calculations.

Setting Behavior VRM Portal
OFF (default) Power Watchdog is the authoritative grid meter; system calculations use its readings Shows "Essential Loads" / "Non-Essential Loads" layout; DC Loads tile is hidden (known VRM limitation)
ON Inverter internal metering is authoritative; Power Watchdog readings are display-only Shows standard layout with "DC Loads" tile visible; Power Watchdog data still appears but is not used for system calculations

Recommendation: Leave OFF for accurate grid metering. Only turn ON if you specifically need DC Loads visible on the VRM portal and accept that the Power Watchdog's readings become informational rather than authoritative.

Known VRM Portal Limitation

The VRM portal (vrm.victronenergy.com) is a closed-source application with rendering logic that differs from the local Cerbo GUI and the venus-html5-app.

When an external grid meter is active (RunWithoutGridMeter = 0), VRM uses an ESS-style layout that:

  • Hides the DC Loads tile entirely (even though /Dc/System/Power is correctly published on D-Bus)
  • Splits consumption into Essential Loads (AC output) and Non-Essential Loads (AC input) instead of showing a single AC Loads value

This is a known, long-standing VRM limitation based on an old design assumption that systems with external grid meters do not have DC loads. It affects all external grid meter drivers, including Victron-maintained ones like dbus-cgwacs and dbus-shelly. We filed venus#1590 to track this with Victron.

The local Cerbo GUI and venus-html5-app (used on MFDs) render correctly in all configurations -- they show DC Loads whenever /Dc/System/Power has a value, and use /Ac/Consumption for AC Loads without the ESS split.

No D-Bus workaround exists; the fix requires a VRM portal UI change by Victron Energy.

Error Code Display (Fronius ProductId Workaround)

The Power Watchdog publishes BLE error codes (0-9) to /ErrorCode on its grid service. However, the Venus OS GUI (ListAcInError.qml) only displays the error code row for two hard-coded product IDs:

  • Fronius PV Inverter (0xA142) — shows the raw error code number
  • Carlo Gavazzi Energy Meter (0xB002) — shows a translated message

For any other ProductId, the error row is hidden entirely.

As a workaround, this service sets its /ProductId to 0xA142 (Fronius). The Fronius code path simply displays the raw error number, which is the correct behavior for our use case. This only affects the error display logic in ListAcInError.qml — no other GUI components use the Fronius product ID for conditional behavior.

We have submitted a pull request to victronenergy/gui-v2 to make error code display generic for all energy meters: gui-v2#2816. Once that PR is accepted, we will switch to a dedicated product ID and remove this workaround.

Configuration

Optional: copy config.default.ini to config.ini to customize:

[DEFAULT]
scan_interval = 60
bluetooth_adapters = hci0,hci1
reconnect_delay = 10
reconnect_max_delay = 120
ble_connection_manager = true
ble_link_caps = hci0:5
ble_wrap_scanner = false

The polling interval is configured per-device via the GUI slider (see above) and is not in the config file. All other configuration is optional. By default the service considers every adapter the kernel exposes and uses sensible defaults.

BLE adapters and coordination

bluetooth_adapters entries are passed to bleak-connection-manager verbatim and also decide which adapter our own scans run on:

Entry Meaning
hci1 joins the shared pool of adapters links may be placed on
AA:BB:CC:DD:EE:FF@hci1 pins that device to hci1; repeat the MAC for an ordered fallback list

ble_connection_manager = false disables the catcher and connects with plain bleak + bleak-retry-connector, uncoordinated with other BLE services.

ble_link_caps (hciX:N) bounds established links per adapter — dongle limits are undocumented, so this is deployment config, not discovery (~5 is a workable start for CSR8510-based adapters, ~7 for Broadcom). A full adapter is passed over instead of failing. An adapter with no cap is never gated.

Service Management

svc -u /service/dbus-power-watchdog  # Start
svc -d /service/dbus-power-watchdog  # Stop
svc -t /service/dbus-power-watchdog  # Restart
svstat /service/dbus-power-watchdog  # Status
tail -f /var/log/dbus-power-watchdog/current | tai64nlocal  # Logs

Credits

Third-Party Software

This project includes velib_python by Victron Energy BV, located in ext/velib_python/. It is licensed under the MIT License:

Copyright (c) 2014 Victron Energy BV

Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the "Software"), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions:

The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software.

THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT.