Skip to content

Commit

Permalink
Add directory utils/signed-windows-inf-files/ with Windows inf files …
Browse files Browse the repository at this point in the history
…for Hantek 6022BE and Hantek 6022BL. Easy installation withotu Zadig (right-click on the inf files and install). Informative names in Device Manager, identifying device and common firmwares loader/openht/sigrok

Signed-off-by: fgrieu <fgrieu@gmail.com>
  • Loading branch information
fgrieu committed Dec 23, 2021
1 parent 31c5ee2 commit d16e151
Show file tree
Hide file tree
Showing 13 changed files with 356 additions and 0 deletions.
Binary file not shown.
53 changes: 53 additions & 0 deletions utils/signed-windows-inf-files/Hantek_6022BE_loader.inf
Original file line number Diff line number Diff line change
@@ -0,0 +1,53 @@
; Installs WinUsb for Hantek 6022BE loader

[Version]
Signature = "$Windows NT$"
Class = USBDevice
ClassGUID = {88BAE032-5A81-49f0-BC3D-A4FF138216D6}
Provider = %ManufacturerName%
CatalogFile=Hantek_6022BE_loader.cat
DriverVer = 12/23/2021, 21.12.23.4
PnpLockDown=1

; ========== Manufacturer/Models sections ===========

[Manufacturer]
%ManufacturerName% = Standard,NTamd64,NTx86

[Standard.NTamd64]
%DeviceName% = USB_Install, USB\VID_04B4&PID_6022

[Standard.NTx86]
%DeviceName% = USB_Install, USB\VID_04B4&PID_6022

; =================== Installation ===================

[USB_Install]
Include=winusb.inf
Needs=WINUSB.NT

[USB_Install.Services]
Include=winusb.inf
AddService=WinUsb,0x00000002,WinUsb_ServiceInstall

[WinUsb_ServiceInstall]
DisplayName = %WinUsb_SvcDesc%
ServiceType = 1
StartType = 3
ErrorControl = 1
ServiceBinary = %12%\WinUSB.sys

[USB_Install.HW]
AddReg=Dev_AddReg

[Dev_AddReg]
; By default, USBDevice class uses iProduct descriptor to name the device
; The following line (uncommented) forces using %DeviceName%
HKR,,FriendlyName,,%DeviceName%
HKR,,DeviceInterfaceGUIDs,0x10000,"{C4B9C054-04B4-6022-367C-22756B7032DB}"

[Strings]
ManufacturerName="Hantek"
ClassName="Universal Serial Bus devices"
WinUsb_SvcDesc="WinUSB Driver"
DeviceName="Hantek 6022BE loader"
Binary file not shown.
53 changes: 53 additions & 0 deletions utils/signed-windows-inf-files/Hantek_6022BE_openht.inf
Original file line number Diff line number Diff line change
@@ -0,0 +1,53 @@
; Installs WinUsb for Hantek 6022BE openht

[Version]
Signature = "$Windows NT$"
Class = USBDevice
ClassGUID = {88BAE032-5A81-49f0-BC3D-A4FF138216D6}
Provider = %ManufacturerName%
CatalogFile=Hantek_6022BE_openht.cat
DriverVer = 12/23/2021, 21.12.23.4
PnpLockDown=1

; ========== Manufacturer/Models sections ===========

[Manufacturer]
%ManufacturerName% = Standard,NTamd64,NTx86

[Standard.NTamd64]
%DeviceName% = USB_Install, USB\VID_04B5&PID_6022

[Standard.NTx86]
%DeviceName% = USB_Install, USB\VID_04B5&PID_6022

; =================== Installation ===================

[USB_Install]
Include=winusb.inf
Needs=WINUSB.NT

[USB_Install.Services]
Include=winusb.inf
AddService=WinUsb,0x00000002,WinUsb_ServiceInstall

[WinUsb_ServiceInstall]
DisplayName = %WinUsb_SvcDesc%
ServiceType = 1
StartType = 3
ErrorControl = 1
ServiceBinary = %12%\WinUSB.sys

[USB_Install.HW]
AddReg=Dev_AddReg

[Dev_AddReg]
; By default, USBDevice class uses iProduct descriptor to name the device
; The following line (uncommented) forces using %DeviceName%
HKR,,FriendlyName,,%DeviceName%
HKR,,DeviceInterfaceGUIDs,0x10000,"{C4B9C054-04B5-6022-367C-22756B7032DB}"

[Strings]
ManufacturerName="Hantek"
ClassName="Universal Serial Bus devices"
WinUsb_SvcDesc="WinUSB Driver"
DeviceName="Hantek 6022BE openht"
Binary file not shown.
53 changes: 53 additions & 0 deletions utils/signed-windows-inf-files/Hantek_6022BE_sigrok.inf
Original file line number Diff line number Diff line change
@@ -0,0 +1,53 @@
; Installs WinUsb for Hantek 6022BE sigrok

[Version]
Signature = "$Windows NT$"
Class = USBDevice
ClassGUID = {88BAE032-5A81-49f0-BC3D-A4FF138216D6}
Provider = %ManufacturerName%
CatalogFile=Hantek_6022BE_sigrok.cat
DriverVer = 12/23/2021, 21.12.23.4
PnpLockDown=1

; ========== Manufacturer/Models sections ===========

[Manufacturer]
%ManufacturerName% = Standard,NTamd64,NTx86

[Standard.NTamd64]
%DeviceName% = USB_Install, USB\VID_1D50&PID_608E&REV_0000

[Standard.NTx86]
%DeviceName% = USB_Install, USB\VID_1D50&PID_608E&REV_0000

; =================== Installation ===================

[USB_Install]
Include=winusb.inf
Needs=WINUSB.NT

[USB_Install.Services]
Include=winusb.inf
AddService=WinUsb,0x00000002,WinUsb_ServiceInstall

[WinUsb_ServiceInstall]
DisplayName = %WinUsb_SvcDesc%
ServiceType = 1
StartType = 3
ErrorControl = 1
ServiceBinary = %12%\WinUSB.sys

[USB_Install.HW]
AddReg=Dev_AddReg

[Dev_AddReg]
; By default, USBDevice class uses iProduct descriptor to name the device
; The following line (uncommented) forces using %DeviceName%
HKR,,FriendlyName,,%DeviceName%
HKR,,DeviceInterfaceGUIDs,0x10000,"{C4B9C054-1D50-608E-0000-22756B7032DB}"

[Strings]
ManufacturerName="Hantek"
ClassName="Universal Serial Bus devices"
WinUsb_SvcDesc="WinUSB Driver"
DeviceName="Hantek 6022BE sigrok"
Binary file not shown.
53 changes: 53 additions & 0 deletions utils/signed-windows-inf-files/Hantek_6022BL_loader.inf
Original file line number Diff line number Diff line change
@@ -0,0 +1,53 @@
; Installs WinUsb for Hantek 6022BL loader

[Version]
Signature = "$Windows NT$"
Class = USBDevice
ClassGUID = {88BAE032-5A81-49f0-BC3D-A4FF138216D6}
Provider = %ManufacturerName%
CatalogFile=Hantek_6022BL_loader.cat
DriverVer = 12/23/2021, 21.12.23.4
PnpLockDown=1

; ========== Manufacturer/Models sections ===========

[Manufacturer]
%ManufacturerName% = Standard,NTamd64,NTx86

[Standard.NTamd64]
%DeviceName% = USB_Install, USB\VID_04B4&PID_602A

[Standard.NTx86]
%DeviceName% = USB_Install, USB\VID_04B4&PID_602A

; =================== Installation ===================

[USB_Install]
Include=winusb.inf
Needs=WINUSB.NT

[USB_Install.Services]
Include=winusb.inf
AddService=WinUsb,0x00000002,WinUsb_ServiceInstall

[WinUsb_ServiceInstall]
DisplayName = %WinUsb_SvcDesc%
ServiceType = 1
StartType = 3
ErrorControl = 1
ServiceBinary = %12%\WinUSB.sys

[USB_Install.HW]
AddReg=Dev_AddReg

[Dev_AddReg]
; By default, USBDevice class uses iProduct descriptor to name the device
; The following line (uncommented) forces using %DeviceName%
HKR,,FriendlyName,,%DeviceName%
HKR,,DeviceInterfaceGUIDs,0x10000,"{C4B9C054-04B4-602A-367C-22756B7032DB}"

[Strings]
ManufacturerName="Hantek"
ClassName="Universal Serial Bus devices"
WinUsb_SvcDesc="WinUSB Driver"
DeviceName="Hantek 6022BL loader"
Binary file not shown.
53 changes: 53 additions & 0 deletions utils/signed-windows-inf-files/Hantek_6022BL_openht.inf
Original file line number Diff line number Diff line change
@@ -0,0 +1,53 @@
; Installs WinUsb for Hantek 6022BL openht

[Version]
Signature = "$Windows NT$"
Class = USBDevice
ClassGUID = {88BAE032-5A81-49f0-BC3D-A4FF138216D6}
Provider = %ManufacturerName%
CatalogFile=Hantek_6022BL_openht.cat
DriverVer = 12/23/2021, 21.12.23.4
PnpLockDown=1

; ========== Manufacturer/Models sections ===========

[Manufacturer]
%ManufacturerName% = Standard,NTamd64,NTx86

[Standard.NTamd64]
%DeviceName% = USB_Install, USB\VID_04B5&PID_602A

[Standard.NTx86]
%DeviceName% = USB_Install, USB\VID_04B5&PID_602A

; =================== Installation ===================

[USB_Install]
Include=winusb.inf
Needs=WINUSB.NT

[USB_Install.Services]
Include=winusb.inf
AddService=WinUsb,0x00000002,WinUsb_ServiceInstall

[WinUsb_ServiceInstall]
DisplayName = %WinUsb_SvcDesc%
ServiceType = 1
StartType = 3
ErrorControl = 1
ServiceBinary = %12%\WinUSB.sys

[USB_Install.HW]
AddReg=Dev_AddReg

[Dev_AddReg]
; By default, USBDevice class uses iProduct descriptor to name the device
; The following line (uncommented) forces using %DeviceName%
HKR,,FriendlyName,,%DeviceName%
HKR,,DeviceInterfaceGUIDs,0x10000,"{C4B9C054-04B5-602A-367C-22756B7032DB}"

[Strings]
ManufacturerName="Hantek"
ClassName="Universal Serial Bus devices"
WinUsb_SvcDesc="WinUSB Driver"
DeviceName="Hantek 6022BL openht"
Binary file not shown.
53 changes: 53 additions & 0 deletions utils/signed-windows-inf-files/Hantek_6022BL_sigrok.inf
Original file line number Diff line number Diff line change
@@ -0,0 +1,53 @@
; Installs WinUsb for Hantek 6022BL sigrok

[Version]
Signature = "$Windows NT$"
Class = USBDevice
ClassGUID = {88BAE032-5A81-49f0-BC3D-A4FF138216D6}
Provider = %ManufacturerName%
CatalogFile=Hantek_6022BL_sigrok.cat
DriverVer = 12/23/2021, 21.12.23.4
PnpLockDown=1

; ========== Manufacturer/Models sections ===========

[Manufacturer]
%ManufacturerName% = Standard,NTamd64,NTx86

[Standard.NTamd64]
%DeviceName% = USB_Install, USB\VID_1D50&PID_608E&REV_0003

[Standard.NTx86]
%DeviceName% = USB_Install, USB\VID_1D50&PID_608E&REV_0003

; =================== Installation ===================

[USB_Install]
Include=winusb.inf
Needs=WINUSB.NT

[USB_Install.Services]
Include=winusb.inf
AddService=WinUsb,0x00000002,WinUsb_ServiceInstall

[WinUsb_ServiceInstall]
DisplayName = %WinUsb_SvcDesc%
ServiceType = 1
StartType = 3
ErrorControl = 1
ServiceBinary = %12%\WinUSB.sys

[USB_Install.HW]
AddReg=Dev_AddReg

[Dev_AddReg]
; By default, USBDevice class uses iProduct descriptor to name the device
; The following line (uncommented) forces using %DeviceName%
HKR,,FriendlyName,,%DeviceName%
HKR,,DeviceInterfaceGUIDs,0x10000,"{C4B9C054-1D50-608E-0003-22756B7032DB}"

[Strings]
ManufacturerName="Hantek"
ClassName="Universal Serial Bus devices"
WinUsb_SvcDesc="WinUSB Driver"
DeviceName="Hantek 6022BL sigrok"
38 changes: 38 additions & 0 deletions utils/signed-windows-inf-files/README.txt
Original file line number Diff line number Diff line change
@@ -0,0 +1,38 @@
These files provide an easy method to bind WinUSB to Hantek 6022BE and 6022BL (in scope mode,
button pressed) with clear dstinction between three common states:
- loader mode (when plugged)
- openht mode (when OpenHantek has loaded it's firmware)
- sigrok mode (when Sigrok or PulseView has loaded it's firmware)

When these bindings are used, the device appears under "Device Manager" as
"Universal Serial Bus devices" with an informative name:
Hantek 6022BE loader Hantek 6022BL loader
Hantek 6022BE openht Hantek 6022BL openht
Hantek 6022BE sigrok Hantek 6022BL sigrok

---
Removing other bindings/drivers (optional, recommended):

The manufacturer's drivers can perhaps be desintalled from "add/remove programs" where they
appear as "Windows Driver Package - ODM (Hantek6022...) USB".

If other bindings appear in "Device Manager" and need to be removed,
ight-click on the device, perform "Uninstall device",
optionally (suggested) tick "Delete the driver software for this device",
confirm.

USBDeview ( https://www.nirsoft.net/utils/usb_devices_view.html ) has an
"Unisntall sected device" option, that does not delete the driver software.

---
To install: Select the desired .inf files, e.g. for a 6022BE:
Hantek_6022BE_loader.inf Hantek_6022BE_openht.inf Hantek_6022BE_sigrok .inf
and right-click to install. This is fast. No reboot or wait is necessary.

Note: Leave the .inf and matching signed .cat files together.

---
Public domin. Use at your own risk.
Only insurance is that these files, as created, are not deliberately malicious.

fgrieu - 2021-12-23

0 comments on commit d16e151