JTech Grid Control

A self-hosted OCPP 1.6J central system and dashboard for the Teltonika TeltoCharge EVC EV charger. Run it on a NAS, a Raspberry Pi, or any machine with Docker, and control your charger from a browser or phone — on your own network, or remotely. You can create a port forward on port 8081 and access this anywhere, alternatively you can just use a VPN for added security

TeltoCharge EVC  ──ws://host:9000/EVC121──▶  central_system.py  ◀──https://host:8080── (FW) remote.yourdomain.com:8081

New in v53

Solar Assistant integration and solar-aware charging. If you run a Solar Assistant inverter, the dashboard now shows it live — battery, solar, load and grid, each with a fill-bar gauge — and drives its work mode to follow the charger. While a car is charging it shares surplus solar to the car when there's enough sun and battery headroom, and protects the battery otherwise, with the thresholds adjustable right on the panel. The active mode is shown as a solid green button.

Since v39, this release also hardens the automation and connection handling:

  • If the charger drops its connection mid-session, the inverter no longer gets stranded on the charging work mode — it returns to sharing the battery, and a background safety net corrects a stuck mode within 30 seconds.
  • A manual work-mode change now holds for a short grace period instead of being immediately overridden by the automation.
  • After a container restart or a WebSocket reconnect, the charger reports its status automatically, so the connector shows online without clicking "Bring online".
  • Usage graphs label each bar with its exact value; the redundant session list under the graphs was removed.

What it does

  • Live dashboard — amps, power, session energy, cost, and a derived state of charge, updating in real time while you charge.

  • Charging schedule — a daily window that caps current outside it, so you charge on off-peak tariffs.

  • Auto-start — begins a session when you plug in, or only inside the schedule window, since OCPP alone can't start a charge on a timer.

  • Charging modes — Regular, Solar-only, Eco and Eco+ via the Teltonika vendor keys (firmware 1.12+).

  • Usage history — every session stored permanently, with per-month energy and cost graphs and a session list, modelled on the Teltonika app's own usage screens.

  • Accurate sessions — a session closes at the real end of charging (cable out, target SOC reached, schedule window closed, or cycle finished), dated by when it started.

  • Cost tracking — set your tariff; each session records the price in force at the time, so changing it later doesn't rewrite history.

  • HTTPS, auth, and a security-audited surface — sign-in, a self-signed certificate generated on first start, strict CSP, and no SQL anywhere.

  • iPhone home-screen app — installable as a PWA; add to home screen from Safari.

  • Solar inverter control (optional) — if you run Solar Assistant, the inverter's work mode can follow the charger and become solar-aware, so the car draws surplus solar when available and spares the battery when it isn't. Off unless configured.

    I created this purely out of frustration as the premium Teltonika Teltocharge series of EV chargers does not allow any remote control except for bluetooth, well it supports OCPP 1.6, then JTech Grid Control was born!

Requirements

  • A TeltoCharge EVC Series charger (other OCPP 1.6J chargers may work but are untested).
  • This is a fully OCPP 1.6 compliant webapp, so other OCPP chargers should work.
  • Docker, or Docker + Container Manager on a Synology NAS.
  • The charger and the host on the same LAN.

Quick start

git clone https://github.com/Lansharkza/jtech-grid-control.git
cd jtech-grid-control
docker compose up -d --build

Then:

  1. Open https://YOUR_HOST:8081/ and accept the certificate warning.
  2. Sign in. If you didn't set OCPP_ADMIN_PASSWORD, a password is printed to the container log on first start: docker compose logs | grep pass.
  3. In the Teltonika app, point the charger's OCPP URL at ws://YOUR_HOST:9081/ (the trailing slash matters) and set the charge point ID.
  4. Edit data/config.env (created on first start) to set your hostname, tariff, and charger ID, Username, PAssword then restart.

If you want to test firts, run the simulator: python simulator.py --id EVC121 --plugged.

Configuration

All settings live in data/config.env, a plain file created on first start. See env.example for the full list with comments. Nothing sensitive ships in the image; passwords and certificates stay on your host.

Solar inverter control (optional)

If you run Solar Assistant, the inverter's work mode can follow the charger. To enable it, add these to data/config.env and restart:

SOLAR_ASSISTANT_HOST=192.168.1.60          # your Solar Assistant device IP
SOLAR_ASSISTANT_USER=admin
SOLAR_ASSISTANT_PASSWORD=your-local-password

Set a local device password in Solar Assistant first if you haven't. Leave SOLAR_ASSISTANT_HOST blank to keep the feature off.

Once set, an inverter panel appears on the dashboard with live battery, solar, load and grid, and the work mode follows charging: while a car charges it shares solar to the car when solar output and battery SOC are above your thresholds (default 5 kW / 40%, adjustable on the panel), and protects the battery otherwise. The exact work-mode strings and thresholds are configurable — see the Solar Assistant block in env.example.

Documentation

Guide For
INSTALL.md First install on Synology, and the common traps
UPGRADE.md Upgrading without losing history
PUBLIC-ACCESS.md Reaching it over the internet, safely
SECURITY.md The security model and audit findings
IPHONE.md Home-screen install and native-app options

Compatibility

Built and tested against the Teltonika TeltoCharge EVC series (tethered, single-phase, 32 A). The OCPP 1.6J implementation is standard, so other chargers may work, but the charging modes and some defaults are Teltonika-specific. Reports of other hardware welcome.

Contributing

Issues and pull requests are welcome. Before opening a PR that touches the dashboard, run python check.py — it catches the CSP and markup mistakes that a browser hides.

License

MIT — see LICENSE.


Reference

OCPP 1.6J central system for the Teltonika TeltoCharge EVC series.

A self-hosted central system (CSMS): the charger dials in over WebSocket, and you drive it from a REST API or the browser dashboard.

TeltoCharge EVC121  ──ws://host:9000/EVC121──▶  central_system.py  ◀──http://host:8080──  you

Files

File What it is
central_system.py The server: OCPP WebSocket endpoint + REST API + dashboard
static/index.html Operator dashboard (no build step, plain HTML/JS)
simulator.py A fake charge point so you can test without hardware
requirements.txt Pinned dependencies
Dockerfile, docker-compose.yml Container build
static/login.html Sign-in page
static/favicon.svg Browser icon
INSTALL.md First install, and the traps
UPGRADE.md Upgrading without losing history
env.example Copy to .env and edit — upgrades never overwrite it
SECURITY.md Audit findings and internet-exposure checklist
IPHONE.md Home screen install, and the native app options
PUBLIC-ACCESS.md Trusted certificates and safe internet exposure
SYNOLOGY.md Synology-specific detail
verify.sh Post-install check
check.py Static check of the pages — run after editing them
healthcheck.py Container healthcheck (HTTP/HTTPS aware)
VERSION Build number and tested dependency versions

Run it

With Docker:

docker compose up -d --build     # dashboard on :8081, OCPP on :9000

See SYNOLOGY.md for Container Manager on a NAS.

Directly:

python -m venv .venv && source .venv/bin/activate
pip install -r requirements.txt
python central_system.py                 # --host / --ocpp-port / --api-port to override
  • OCPP endpoint: ws://<host>:9000/<ChargePointId>
  • Dashboard: http://<host>:8080/
  • Sign in at http://<host>:8080/login

Set OCPP_ADMIN_USER and OCPP_ADMIN_PASSWORD. If you don't, a random password is generated at startup and printed to the log — check it with docker logs ocpp-cs | head -20.

Test without the charger, in a second terminal:

python simulator.py --url ws://localhost:9000 --id SIM001

Point the EVC121 at it or generic OCPP charger

Configuration happens in the Teltonika app over Bluetooth, not over the network:

  1. Get the charger onto the same network as the server — Ethernet, Wi-Fi, or its SIM slot. Ethernet is DHCP by default; turn DHCP off if you want a static address.
  2. In the Teltonika app, open the OCPP settings, enter the server URL and a charge point identity, enable OCPP, and save. The app shows whether the connection succeeded.
    • URL: ws://<server-ip>:9000/ — Teltonika requires the URL to end with /. The server tolerates the //EVC121 path that produces.
    • Charge point ID: usually the charger's serial number. It becomes the path segment and the ID in the dashboard.
  3. Watch the server log. You should see Connected, then BootNotification, then a StatusNotification of Available.

Things to know about this charger:

  • When OCPP is enabled, the charger's own scheduled charging and randomized-delay features stop applying. The backend is in charge.
  • Defaults are unhelpfully slow. HeartbeatInterval and MeterValueSampleInterval both default to 3600, and MeterValuesSampledData defaults to the energy register only. Set them on first connection or the dashboard will look dead. Minimum meter interval is 5s.
  • AuthorizeRemoteTxRequests defaults to 1, so a remote start triggers an Authorize first. This server accepts any tag by default (ACCEPT_UNKNOWN_TAGS = True), so it works either way — but set the key to 0 if you want to skip the round-trip.
  • This unit is tethered, so UnlockConnector is not applicable — the charger answers NotSupported. The button is removed from the dashboard; the API route is still there if you ever swap to a socket model. NumberOfConnectors is 1 and read-only, so connector 1 is the only valid target.
  • Supported measurands: Energy.Active.Import.Register, Current.Import, Current.Offered, Voltage, Temperature, Power.Active.Import. The dashboard shows whichever arrive and falls back to current × voltage if power is absent.
  • Vendor keys beyond the documented set (solar charging, for example) vary by firmware — run "Read all keys" against your unit to see what yours exposes.

What you can do

Dashboard button OCPP message
Start charging RemoteStartTransaction
Stop charging RemoteStopTransaction
Apply limit / Clear limit SetChargingProfile / ClearChargingProfile (TxDefaultProfile, amps)
Take offline / Bring online ChangeAvailability
Regular / Solar only / Eco / Eco+ ChangeConfiguration on Solar and SolarCharging
Apply / clear schedule SetChargingProfile recurring daily / ClearChargingProfile
Apply recommended 13 × ChangeConfiguration
Measurands seen local diagnostic, no message sent
Download / Restore backup local, exports and reloads history and settings
— (tethered unit, no unlock) UnlockConnector — API only
Soft / Hard reset Reset
Read all keys / Write key GetConfiguration / ChangeConfiguration

API-only (no button yet): ClearCache, GetCompositeSchedule, ReserveNow, CancelReservation, GetLocalListVersion, SendLocalList, GetDiagnostics, UpdateFirmware, TriggerMessage.

Inbound messages handled: BootNotification, Heartbeat, StatusNotification, Authorize, StartTransaction, StopTransaction, MeterValues, DataTransfer, FirmwareStatusNotification, DiagnosticsStatusNotification.

Curl equivalents

curl localhost:8080/api/chargers
curl -X POST localhost:8080/api/chargers/EVC121/start  -H 'Content-Type: application/json' -d '{"connectorId":1,"idTag":"DEMO"}'
curl -X POST localhost:8080/api/chargers/EVC121/limit  -H 'Content-Type: application/json' -d '{"connectorId":1,"limitAmps":10,"numberPhases":3}'
curl "localhost:8080/api/chargers/EVC121/configuration"
curl -X POST localhost:8080/api/chargers/EVC121/configuration -H 'Content-Type: application/json' -d '{"key":"MeterValueSampleInterval","value":"30"}'

Signing in

Variable Default Notes
OCPP_ADMIN_USER admin
OCPP_ADMIN_PASSWORD generated Printed to the log if unset
OCPP_COOKIE_SECURE 0 Set to 1 behind HTTPS so the cookie never travels in the clear

Sessions last 8 hours and live in memory — a restart signs you out. Sign-in is rate-limited to 5 failures per IP per 5 minutes. Every API route and the dashboard itself require a valid session; the only unauthenticated routes are /login and the login endpoint.

Charging modes (This is for Teltonika but should work for others too)

Teltonika added two vendor keys in firmware 1.12:

Key Values Meaning
Solar 0, 1 Solar charging feature on or off
SolarCharging regular, solar, eco, eco_plus Which profile is active

The mode buttons write both: picking anything other than Regular sets Solar=1 first, then the profile. These are not part of the OCPP standard, so a charger on older firmware returns them as unknown keys — the dashboard detects that and disables the buttons rather than pretending.

Solar modes also need the feature commissioned with a supported energy meter. Without one the charger has no import/export reading to work from.

Set these on first connection

Values verified against Teltonika's published key table — anything outside the accepted range comes back Rejected.

I have created a "apply recommendations" button to apply all the recommended defaults

Key Set to Charger default Accepted range
HeartbeatInterval 60 3600 60–86400
MeterValueSampleInterval 30 3600 5–84600
MeterValuesSampledData Energy.Active.Import.Register,Power.Active.Import,Current.Import,Voltage,Temperature energy only the six measurands above
AuthorizeRemoteTxRequests 0 1 0, 1
ConnectionTimeOut 120 120 1–3600
WebSocketPingInterval 10 10 1–1200

Note the booleans are 0/1, not true/false.

Smart-charging ceilings the server respects for you: rate unit must be Current (amps, not watts), stack level max 5, max 5 schedule periods, max 9 profiles installed.

If you turn on the charger's security profile

SecurityProfile defaults to 0 (no auth). If you raise it to 1 or 2, the charger sends HTTP Basic credentials — charge point ID as username, AuthorizationKey (32–40 chars) as password. Give the server the same key and it will enforce it:

export OCPP_AUTHORIZATION_KEY="your-32-to-40-character-key"
python central_system.py

Profile 2 and 3 also require TLS, so you'd put wss:// in front of it.

Troubleshooting

  • Charger never appears. The server requires the ocpp1.6 subprotocol and closes anything else — check the log for that message. Then check firewalls on port 9000 and that the URL scheme is ws:// not http://.
  • Remote start is accepted but nothing happens. The car has to be plugged in and the connector in Preparing — on a tethered unit that means the cable is in the vehicle, not just hanging on the holster. If AuthorizeRemoteTxRequests is true, the idTag you send must pass Authorize.
  • Current limit ignored. Check the charger's installer setting for maximum grid current — the profile can only lower the ceiling, not raise it. Some firmware also only honours TxProfile while a transaction is active; try purpose TxProfile if TxDefaultProfile doesn't stick.
  • Timeouts on commands. The default response_timeout is 30s. A charger on a weak mobile signal may need longer.

Dashboard

Four live gauges — amps, kW, kWh this session, and solar kW — laid out 2×2 on a phone and 4-across on a desktop. Each arc grades colour with load. Below them a session timer, state, tag, transaction, mode and running cost; then voltage, temperature, current offered, lifetime meter, tariff and session cost.

Polling runs at 1s while a session is active and 4s when idle. The real ceiling is the charger: MeterValueSampleInterval has a 5s minimum, so nothing updates faster than that regardless of polling.

State of charge

Shown as a bar under the gauges rather than a ring: fill runs light violet to deep violet as charge builds, with a lime marker at the target SOC from the Control card. The caption reads out the kWh still needed to reach target.

The charger cannot read SOC. AC charging over the standard control pilot carries no such signal — that needs ISO 15118, and Teltonika's measurand list does not include SoC. So SOC is derived:

soc = startSoc + (delivered kWh x efficiency) / batteryKwh x 100

You set battery capacity and the SOC at plug-in; efficiency defaults to 0.9 to account for AC charging losses. If a charger ever does send an SoC measurand, that is used instead and the caption says "from vehicle" rather than "estimated".

Set the SOC at plug-in each time you connect, or the gauge has no starting point.

Gauges

Amps against the current limit, kW against the nominal ceiling, kWh delivered this session against the energy needed to reach target SOC (40 kWh if no starting SOC is set), and session cost against what it costs to get from the plug-in SOC to the target SOC at the current tariff — so the ceiling tracks the actual battery state rather than a fixed kWh figure. Colour grades sky blue through amber to rose.

Solar power is still tracked in the API (session.solarW, session.solarSource) but is no longer a gauge: OCPP 1.6's measurand list is a fixed enum with no solar entry, so a compliant charger cannot report it directly and the value was often inferred rather than measured. Power.Active.Export is used when the charger sends it.

When a session is recorded

A session closes on whichever real end-of-charging event happens first, so the recorded end is always the true end:

Event Charger signal Reason logged
Cable pulled StopTransaction EVDisconnected
Car reaches target SOC SuspendedEV SOCLimitReached
Schedule window closes watcher stop at boundary ScheduleWindowClosed
Charge cycle finishes Finishing / Available Local

The last row matters because some firmware ends a charge without a clean StopTransaction; catching the status change stops a session hanging open.

Without this, a charge that finishes at 2am but stays plugged in until morning would be logged as an all-night session. If the car resumes (surplus returns, or the battery drops below target) the same session continues and is updated in place rather than split in two. SuspendedEVSE — the charger pausing for a 0 A schedule window, not the car finishing — is deliberately not a trigger. Disable the whole behaviour with OCPP_FINALISE_ON_SUSPENDED_EV=0.

Sessions are dated by when they start. An overnight charge counts on the day it began, not the day it ended.

Usage

A month-at-a-time view with two per-day bar charts — power consumption in green, money spent in cyan, each with a running total — over modelled on the Teltonika app: a totals bar (energy, time, cost) over a list of that month's sessions, newest first, each showing kWh, duration, timestamp and cost. The charts and list share one month selection. The arrows step between months, back as far as records exist. Sessions are kept effectively forever — the cap is 100,000, raisable with OCPP_HISTORY_MAX.

Note: OCPP 1.6 has no command to read a charger's past transactions, so this only contains sessions recorded while the server was running and persisting. Sessions that happened before then live only in the charger and its own app.

History and sessions

The history card defaults to the last 7 days but takes any range: 7-day, 30-day and this-month buttons, plus two date fields for an arbitrary span up to a year. Days as rows, newest first, with a total line.

Below it, an All sessions table lists every session ever recorded, 25 to a page, newest first, with Newer/Older paging. Nothing rolls off — the 7-day view just shows a window onto the same data.

Last 7 days

Totals for charge time, peak draw, energy, cost and session count, then a table with one row per day — newest first — showing charge time, energy and cost, with a 7-day total row. Days with no charging show dashes rather than zeros. A session in progress is included in the totals. Completed sessions are appended to /app/data/sessions.json at StopTransaction with the tariff in force at that moment, so changing the price later does not rewrite history. Last 2000 sessions are kept.

Schedule and auto-start

These are two halves of one job, and the schedule alone is not enough.

A charging profile can only cap current inside a transaction that already exists. Nothing in OCPP 1.6 opens a transaction on a timer — that needs an RFID tap, a RemoteStartTransaction, or the charger's own free-vend mode. So a schedule on its own leaves you pressing Start.

Schedule sends a daily recurring TxDefaultProfile allowing current inside the window and 0 A outside it. Overnight windows are handled. Some firmware rejects a 0 A period; the card reports the status if yours does.

Auto-start is the server watching for a connector in Preparing (or suspended) with no transaction, and issuing RemoteStartTransaction itself. Three settings:

Mode Behaviour
off Nothing automatic. Press Start.
plugged Starts as soon as the cable is in the car.
schedule Starts only inside the window, and stops when it closes.

Times are read from the container clock, so TZ in the compose file must be right. The image installs tzdata — without it, python:slim ignores TZ and runs on UTC, which shifts every window by the local offset. The dashboard shows the timezone the server is actually using next to the schedule, and the startup log warns if it fell back to UTC.

The watcher runs every 20 seconds and waits 2 minutes between attempts on the same connector, so a charger refusing to start does not get hammered. Sessions it opens are logged as AutoStart / AutoStop in the message log.

Use both together: auto-start opens the session, the profile enforces the current cap.

Times are interpreted in the container's timezone, set by TZ in the compose file.

Tariff

Price per kWh is stored server-side, so it is the same on every device, and persisted to /app/data when that volume is writable. Default R3.55, set via OCPP_PRICE_PER_KWH.