Notifications
You must be signed in to change notification settings - Fork 1.9k
Description
Link
https://www.aliexpress.com/item/1005010563627554.html
Database entry
{"id":68,"type":"Router","ieeeAddr":"0xa4c1381530770784","nwkAddr":36775,"manufId":4417,"manufName":"_TZE204_mby4kbtq","powerSource":"Mains (single phase)","modelId":"TS0601","epList":[1,242],"endpoints":{"1":{"profId":260,"epId":1,"devId":81,"inClusterList":[4,5,61184,0],"outClusterList":[25,10],"clusters":{"genBasic":{"attributes":{"65503":"�0\u00171i�0\u00171iV5\u00171iV5\u00171i","65506":56,"65508":0,"65534":0,"stackVersion":0,"dateCode":"","appVersion":74,"manufacturerName":"_TZE204_mby4kbtq","zclVersion":3,"modelId":"TS0601","powerSource":1}}},"binds":[],"configuredReportings":[],"meta":{}},"242":{"profId":41440,"epId":242,"devId":97,"inClusterList":[],"outClusterList":[33],"clusters":{},"binds":[],"configuredReportings":[],"meta":{}}},"appVersion":74,"stackVersion":0,"hwVersion":1,"dateCode":"","zclVersion":3,"interviewCompleted":true,"interviewState":"SUCCESSFUL","meta":{"configured":-708457359},"lastSeen":1770368800634}
Zigbee2MQTT version
2.8.0 (unknown)
External converter
{
"description": "Tuya Zigbee Gas Sensor 3",
"exposes": [
{
"access": 1,
"description": "Indicates whether the device detected gas",
"label": "Gas",
"name": "gas",
"property": "gas",
"type": "binary",
"value_off": false,
"value_on": true
},
{
"access": 1,
"description": "Indicates sensor preheat is active",
"label": "Preheat status",
"name": "preheat_status",
"property": "preheat_status",
"type": "binary",
"value_off": false,
"value_on": true
},
{
"access": 1,
"description": "Indicates whether a fault was detected",
"label": "Fault alarm",
"name": "fault_alarm",
"property": "fault_alarm",
"type": "binary",
"value_off": false,
"value_on": true
},
{
"access": 3,
"description": "Alarm test switch",
"label": "Alarm switch",
"name": "alarm_switch",
"property": "alarm_switch",
"type": "binary",
"value_off": "OFF",
"value_on": "ON"
},
{
"access": 3,
"description": "Silence the alarm",
"label": "Silence",
"name": "silence",
"property": "silence",
"type": "binary",
"value_off": false,
"value_on": true
},
{
"access": 1,
"category": "diagnostic",
"description": "Link quality (signal strength)",
"label": "Linkquality",
"name": "linkquality",
"property": "linkquality",
"type": "numeric",
"unit": "lqi",
"value_max": 255,
"value_min": 0
}
],
"model": "ZSS-QY-GL-U-EN",
"options": [],
"source": "external",
"supports_ota": false,
"vendor": "TuYa"
}What does/doesn't work with the external definition?
Working as expected
Notes
software_build_id: undefined
date_code: ``
endpoints:
{"1":{"clusters":{"input":["genGroups","genScenes","manuSpecificTuya","genBasic"],"output":["genOta","genTime"]}},"242":{"clusters":{"input":[],"output":["greenPower"]}}}