Fix battery reporting and address an issue with use of fahrenheit as the unit #3043
Fix battery reporting and address an issue with use of fahrenheit as the unit #3043
Conversation
…values to the setpoints are not truncated to 0.5 before being set since doing so makes it very difficult to achieve close to integer fahrenheit settings - owing to the fact that it appears the only way to set values for thermostats within this framework is using celsius.
…elsius_fahrenheit
The Zigbee spec is in celsius, therefore all Zigbee devices are controlled through celsius. Instead of adding a new converter, I suggest to take a more generic approach by modifying the existing converters (e.g.
devices:
'0x12345678':
friendly_name: 'my thermostat'
thermostat_unit: 'fahrenheit'
- For the `toZigbee` converters you can access this option via: `meta.options.thermostat_unit`
- For the `fromZigee` converters it is: `options.thermostat_unit`
- If the option is set, convert from Fahrenheit -> celsius. |
…tat can have based on experimental results.
1) Define a new config value that allows a thermostat to be designated as fahrenheit 2) If the config flag is set, convert the incoming celsius value (which was already converted from an original input fahrenheit value in the controlling software) back to fahrenheit. 3) Now round the converted fahrenheit value to 0 or 0.5 as appropriate 4) Now convert the resulting fahrenheit value back to celsius and round it to two decimal places The reult is that the thermostat will be set with a setpoint in celsius which will be equivalent to the rounded fahrenheit value based on the original fahrenheit provided by the controlling software. Example: User entered input value is 71.8 F 71.8 F = 21.111111111 C convert 21.11 C (input to zigbee-herdsman-converters) to F: = 71.798 F Round 71.798 F to 72 F Concert 72 F to 22.2222222 C 22.22 C = 71.996 F When the value is read back by the user it will be represnted as 72 F
…values to the setpoints are not truncated to 0.5 before being set since doing so makes it very difficult to achieve close to integer fahrenheit settings - owing to the fact that it appears the only way to set values for thermostats within this framework is using celsius.
…tat can have based on experimental results.
1) Define a new config value that allows a thermostat to be designated as fahrenheit 2) If the config flag is set, convert the incoming celsius value (which was already converted from an original input fahrenheit value in the controlling software) back to fahrenheit. 3) Now round the converted fahrenheit value to 0 or 0.5 as appropriate 4) Now convert the resulting fahrenheit value back to celsius and round it to two decimal places The reult is that the thermostat will be set with a setpoint in celsius which will be equivalent to the rounded fahrenheit value based on the original fahrenheit provided by the controlling software. Example: User entered input value is 71.8 F 71.8 F = 21.111111111 C convert 21.11 C (input to zigbee-herdsman-converters) to F: = 71.798 F Round 71.798 F to 72 F Concert 72 F to 22.2222222 C 22.22 C = 71.996 F When the value is read back by the user it will be represnted as 72 F
…thub.com/nkasrawi/zigbee-herdsman-converters into centralite_thermostat_celsius_fahrenheit
My revised solution based on @Koenkk suggestion is to introduce a configuration variable which can be set on the thermostat configuration and which controls conditional logic which will either perform the current logic (if using Celsius) or perform the following alternate logic (if using Fahrenheit):
This will ensure that the final read back Celsius value, when converted to Fahrenheit will be aligned to 0.0/0.5. To trigger this specific behavior, include a configuration value for the specific device: '0x000d6f000b4f5868': |
2) Remove previously added converters in toZigbee.js that are no longer needed
Thanks! |
I recently installed a Centralite Pearl thermostat and I'm in the US so of course we use Fahrenheit here. The battery was always reporting 27% capacity even when the batteries were fresh, so I made a change which now reports 100% on fresh batteries - I'm still waiting to see what happens if/when the batteries drain (they are a battery backup so it may be a while).
I also ran into the issue as a result of using Fahrenheit. Since the zigbee spec requires the use of Celsius for temperatures, the input values for the setpoints have to be set in Celsius. In the case where the user supplied input values are fahrenherit, the automation software (in my case openhab) is responsible for converting them into Celsius. However, the logic in the herdsman converters truncates input Celsius values to +/- 0.5 by doing:
Math.round((value * 2).toFixed(1)) / 2
This resulted in an unfortunate situation because the final effective Fahrenheit value that was being sent to the thermostat in Celsius was often different from the original provided integer value - sometimes by almost one full degree fahrenheit.
My revised solution based on @Koenkk suggestion is to introduce a configuration variable which can be set on the thermostat configuration and which controls conditional logic which will either perform the current logic (if using Celsius) or perform the following alternate logic (if using Fahrenheit):
This will ensure that the final read back Celsius value, when converted to Fahrenheit will be aligned to 0.0/0.5.
To trigger this specific behavior, include a configuration value for the specific device:
I also removed the references to unoccupied setpoints since this thermostat doesn't understand that concept.