A real-time Remote Photoplethysmography (rPPG) system that estimates heart rate from a standard webcam using the Plane-Orthogonal-to-Skin (POS) algorithm proposed by Wang et al. (2017). The system performs live facial analysis, extracts subtle skin color variations, estimates the Blood Volume Pulse (BVP), and computes heart rate without any physical contact.
Unlike many demonstration projects that simply display an estimated heart rate, this implementation also evaluates signal quality using Spectral Signal-to-Noise Ratio (SNR) and introduces quasi-periodicity detection to determine when the cardiac signal is sufficiently reliable for reporting a stable heart rate.
-
Real-time heart rate estimation using any webcam
-
Implementation of the POS (Plane-Orthogonal-to-Skin) algorithm
-
OpenFace-based forehead Region of Interest (ROI)
-
Automatic fallback to OpenCV Haar Cascade when OpenFace is unavailable
-
Real-time FFT-based heart rate estimation
-
Spectral Signal-to-Noise Ratio (SNR) estimation
-
Quasi-periodicity detection for reliable signal locking
-
Live overlays including:
- Heart Rate
- Signal Quality (SNR)
- Face Detection
- Buffer Status
- Remaining Time
- FPS
-
Automatic HTML report generation
-
Interactive plots of physiological signals
-
Dark themed report with embedded graphs
-
Automatic termination when:
- Stable cardiac signal is detected
- Maximum recording duration is reached
-
No wearable sensors required
The pipeline follows the POS algorithm proposed by Wang et al.
Webcam
│
▼
Face Detection
│
▼
Forehead ROI Extraction
(OpenFace / Haar Cascade)
│
▼
Mean RGB Extraction
│
▼
RGB Signal Buffer
│
▼
POS Projection
│
▼
Detrending
│
▼
Butterworth Bandpass Filter
│
▼
FFT
│
▼
Heart Rate Estimation
│
▼
Spectral SNR
│
▼
Quasi-Periodicity Detection
│
▼
Heart Rate Lock
The system first attempts to locate facial landmarks using OpenFace.
If OpenFace is unavailable, it automatically switches to an OpenCV Haar Cascade detector.
This ensures the application remains usable even without OpenFace installed.
Once the face is detected, the forehead is selected as the Region of Interest because it typically contains:
- minimal facial movement
- limited expression changes
- strong pulsatile skin signal
- fewer motion artifacts
Each frame is resized and converted to RGB.
The average Red, Green and Blue intensity values are computed for every frame.
These RGB values form three temporal signals.
The Plane-Orthogonal-to-Skin algorithm normalizes RGB channels and projects them into a space that suppresses illumination changes while amplifying blood volume variations.
The implementation follows the algorithm introduced in:
Wang W., den Brinker A.C., Stuijk S., de Haan G. Algorithmic Principles of Remote PPG IEEE Transactions on Biomedical Engineering, 2017.
The extracted waveform undergoes:
- Detrending
- Fourth-order Butterworth Bandpass Filtering
- Physiological frequency isolation (0.75–3.33 Hz)
This corresponds to approximately:
45–200 BPM
The processed waveform is transformed into the frequency domain using the Fast Fourier Transform (FFT).
The dominant spectral peak within the physiological heart-rate band is selected as the estimated heart rate.
Signal quality is estimated using
SNR = Peak Magnitude / Mean Magnitude
Higher SNR indicates:
- cleaner physiological signal
- lower motion artifacts
- more reliable heart rate estimation
Instead of immediately reporting the first detected peak, the system verifies that:
- spectral SNR exceeds a predefined threshold
- recent heart-rate estimates remain stable
Only after both conditions are satisfied is the signal considered physiologically reliable.
This significantly reduces unstable measurements.
During execution the application displays:
- Current Heart Rate
- Face Detection Status
- Buffer Progress
- Remaining Time
- FPS
- Spectral SNR
- Signal Lock Status
- Live Countdown Bar
Webcam interface while the system is collecting physiological information before heart rate estimation.
Final result after quasi-periodicity has been detected and a stable heart rate has been estimated.
Shows
- Heart Rate over Time
- Spectral SNR over Time
These plots illustrate convergence toward a stable physiological signal.
Final 10-second processed Blood Volume Pulse (BVP) waveform obtained from the POS algorithm.
Temporal RGB intensity values extracted from the forehead Region of Interest.
These raw signals form the basis for the POS projection.
After every recording session an HTML report is generated automatically.
The report includes:
- Session Summary
- Final Heart Rate
- Signal Quality
- Heart Rate Statistics
- Detector Information
- Configuration Parameters
- Heart Rate Timeline
- Spectral SNR Timeline
- Raw RGB Signal
- Final rPPG Waveform
.
├── images/
│ ├── live_detection.png
│ ├── final_result.png
│ ├── hr_snr_plot.png
│ ├── rppg_waveform.png
│ └── raw_rgb_signal.png
│
├── generated HTML reports
│
│
├── main.py
├── README.md
└── requirements.txt
Clone the repository
git clone https://github.com/JeetAshwarSingh/HeartVision.gitInstall dependencies
pip install opencv-python numpy scipy pandas matplotlibTo use landmark-based forehead extraction:
- Install OpenFace.
- Set
USE_OPENFACE = True- Update
OPENFACE_BIN = "/path/to/FeatureExtraction"If OpenFace is unavailable, the system automatically falls back to Haar Cascade face detection.
python main.pyPress Q at any time to terminate the session.
The following parameters can be modified inside the source code.
| Parameter | Description |
|---|---|
| WINDOW_SEC | Sliding signal window |
| MAX_DURATION_SEC | Maximum recording duration |
| HR_LOW_HZ | Lower heart-rate frequency |
| HR_HIGH_HZ | Upper heart-rate frequency |
| SNR_THRESHOLD | Minimum acceptable signal quality |
| STABILITY_WINDOW | Consecutive HR estimates |
| STABILITY_TOLERANCE | Allowed HR variation |
| USE_OPENFACE | Enable landmark detector |
The implementation follows the POS algorithm proposed by Wang et al. (2017).
Reported benchmark performance on the UBFC-rPPG dataset from later comparative studies:
| Dataset | Algorithm | MAE (BPM) ↓ | RMSE (BPM) ↓ | Pearson r ↑ |
|---|---|---|---|---|
| UBFC-rPPG | POS | 2.44 | 6.61 | 0.94 |
Note: These values are reported in the literature for the original POS algorithm and are not measurements of this implementation.
- Performance decreases under rapid head motion.
- Strong illumination changes may affect signal quality.
- Dark environments reduce estimation accuracy.
- Webcam frame rate influences measurement precision.
- This project is intended for research and educational purposes only and should not be used as a medical device.
If you use this project in your research, please cite:
@article{wang2017pos,
title={Algorithmic Principles of Remote PPG},
author={Wang, Wei and den Brinker, Albertus C. and Stuijk, Sander and de Haan, Gerard},
journal={IEEE Transactions on Biomedical Engineering},
year={2017},
volume={64},
number={7},
pages={1479--1491}
}- Wang et al. for the POS algorithm.
- OpenFace for landmark-based face analysis.
- OpenCV for computer vision utilities.
- NumPy, SciPy and Matplotlib for scientific computing and visualization.
This project is intended for academic, educational and research purposes. Pull requests are welcome to this repository. If you are planning to do something, consider opening an issue first so we can discuss the direction before you may write the code.