Hi,
I run a dual 15k with exports but without grid meter. Installer didn't think it was necessary.... mostly true, but your code doesn't support that.
I looked at the log and made a few tweaks that seem to work. Code below. Sorry, should do a proper PR, but... yeah, sorry.
I tweaked it a bit by parsing more values:
if k in ("pvPower", "battPower", "gridOrMeterPower", "loadOrEpsPower", "soc",
"gridTo", "toGrid", "existsMeter"):
live_data[k] = v
and - changing the parsing to this:
# ----- Grid import/export -----
# Priority 1: Use meter readings if meters exist and have data
meter_a = self._safe_float(data.get("meterA"))
meter_b = self._safe_float(data.get("meterB"))
meter_c = self._safe_float(data.get("meterC"))
grid_net = meter_a + meter_b + meter_c
exists_meter = data.get("existsMeter", False)
if exists_meter and grid_net != 0.0:
# Meters are installed and reporting non-zero
if grid_net > 0:
sensors["grid_import_power"] = grid_net
sensors["grid_export_power"] = 0.0
else:
sensors["grid_import_power"] = 0.0
sensors["grid_export_power"] = abs(grid_net)
elif exists_meter and grid_net == 0.0:
# Meters exist but reading zero - trust it
sensors["grid_import_power"] = 0.0
sensors["grid_export_power"] = 0.0
else:
# Priority 2: No meters - use flow direction flags
grid_power_val = self._safe_float(data.get("gridOrMeterPower"))
grid_to = data.get("gridTo", False)
to_grid = data.get("toGrid", False)
if grid_to:
sensors["grid_import_power"] = grid_power_val
sensors["grid_export_power"] = 0.0
elif to_grid:
sensors["grid_import_power"] = 0.0
sensors["grid_export_power"] = grid_power_val
else:
# Priority 3: Explicit keys as last resort
sensors["grid_import_power"] = self._safe_float(data.get("gridImportPower", 0.0))
sensors["grid_export_power"] = self._safe_float(data.get("gridExportPower", 0.0))