There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Sorry for the delay in looking at this. I think there may be some challenges with rerunning suites in general, like whether tests will rerun cleanly after either succeeding or failing, whether you want to rerun tests that already ran and passed, whether you just want to rerun on tests that were not run or on tests that failed or on all tests. It might be nice to be able to choose some of that when running the suite again "manually". But I think this is a good step forward.
My main comment is that I don't think "incremental" is a good name for the option. How about "nocleanbuild" or something like it. It could be that settings (-s) will be use for setting up cases and other things and "incremental" is not meaningful when all it's doing is resetting the CLEANBUILD default. If we can make that change, I think we can merge the PR. Thanks!
Thanks for your comments.
From what I tested, the tests run cleanly after success or failure.
You are right that some additional flexibility could be good, maybe for a latter PR. For now, all tests are rerun. Regarding the name of the option, would "buildincremental" work, or "incrementalbuild' ? I just thought that since it's pretty standard terminology in software engineering, we might as well use it. But It's not that important. |
I see, you are using "incremental" to mean a typical make build based on the current build without a clean. I'm not sure I've heard that term used in that way before, but it could be. I would propose that we add two new settings, called either "cleanbuild" and "nocleanbuild" OR "buildclean" and "nobuildclean" OR "buildincremental" and "buildclean". I think the last (buildincremental and buildclean) is probably my preferred option at this point. So, if you agree, could you change the "incremental" to "buildincremental" and while you are doing that, add another option which is "buildclean" which is the current default, but I think it's worth adding it as a setting if we are adding the other. Thanks! |
Small modifications to be able to re-run test suites with incremental compilation.
incremental
option (setsICE_CLEANBUILD
to false)suite.run
file tosuite.submit
and add asuite.run
file that runs the suite interactivelysuite.run
andsuite.submit
so that theincremental
option can be effective.Developer(s): Philippe Blain
Please suggest code Pull Request reviewers in the column at right. @apcraig
Are the code changes bit for bit, different at roundoff level, or more substantial?
BFB - no change to code.
Please include the link to test results or paste the summary block from the bottom of the testing output below.
Does this PR create or have dependencies on Icepack or any other models?
No. If you agree with these changes I can make a similar PR for Icepack.
Is the documentation being updated with this PR? (Y/N) Yes
Example 11 for test suites,
Some hints,
Preset options
If not, does the documentation need to be updated separately at a later time? (Y/N)
Note: "Documentation" includes information on the wiki and .rst files in doc/source/,
which are used to create the online technical docs at https://readthedocs.org/projects/cice-consortium-cice/.
I also did some minor editing of the documentation, including fixing some indentation.