Skip to content

Latest commit

 

History

3 Commits

Folders and files

NameName
Last commit message
Last commit date
 
 
 
 
 
 
 
 

Repository files navigation

Boiler Controller — Domoticz plugin

Python plugin for Domoticz that turns your electric boiler into a "water battery". Instead of exporting surplus solar or dynamic-tariff energy to the grid, the plugin reads the surplus reported by your P1 smart meter and sends it straight to the Boiler Controller (BC) device so you store it as hot water.

Features

  • Reads live consumption/production from your P1 smart meter — either a single signed net device, or a pair of separate return + usage devices — through the Domoticz JSON API.
  • Controls the Boiler Controller (BC) over HTTP using watt-based setpoints.
  • Four control modes: auto, manual, on, off.
  • Exposes device telemetry as Domoticz devices (power, energy, heating percentage, temperature, RSSI, firmware, IP).
  • Built-in calibration support — start a manual run from a push button, or let the device calibrate itself automatically over time.

Installation

Domoticz expects plugins to live under <domoticz>/plugins/<Name>/plugin.py. Create that directory and copy (or clone) this file into it:

mkdir -p <domoticz>/plugins/BoilerController
cp plugin.py <domoticz>/plugins/BoilerController/plugin.py

Or via git:

cd <domoticz>/plugins
git clone https://github.com/BoilerController/boiler-controller-domoticz.git BoilerController

(on a typical Raspberry Pi install <domoticz> is /home/pi/domoticz.)

  1. Make sure Domoticz is started with Python plugin support enabled (see the Domoticz wiki).
  2. Restart Domoticz.
  3. Go to Setup → Hardware and add a new hardware of type Boiler Controller.

Configuration

Field Description
BC Device IP / Host IP address or hostname of your Boiler Controller (e.g. 192.168.1.50). May also be a full http://... URL.
BC Device Port HTTP port of the BC device (default 80).
Poll interval (s) How often the plugin polls the BC and (re)applies the control mode (default 10).
P1 sensor mode net — single signed P1 device (negative = exporting). split — two separate devices (export + import).
Domoticz JSON URL Local Domoticz API endpoint (default http://127.0.0.1:8080). Used to read the P1 values.
P1 Net IDX / Return IDX IDX of the Domoticz device providing the net P1 value (net mode) or the export value (split mode).
P1 Usage IDX Only in split mode: IDX of the import (usage) device.
Debug Domoticz debug level (use Basic Debugging when troubleshooting).

If your Domoticz instance uses basic auth, supply credentials in the URL: http://user:pass@127.0.0.1:8080.

About the Domoticz JSON URL field

This is the base URL of the JSON/HTTP API of the same Domoticz instance the plugin is running in. The plugin does not read your P1 meter directly — that device is already configured in Domoticz. Instead it asks Domoticz for the current value by calling:

GET <Domoticz JSON URL>/json.htm?type=command&param=getdevices&rid=<IDX>

…and parses the Usage / Data field from the response. In split mode it does this for both the Return IDX and the Usage IDX.

When to change it from the default http://127.0.0.1:8080:

  • Domoticz listens on a non-standard port (e.g. http://127.0.0.1:8084).
  • Domoticz uses HTTPS (e.g. https://127.0.0.1:443).
  • Domoticz requires basic auth — embed the credentials: http://user:pass@127.0.0.1:8080.
  • The plugin and Domoticz run on different hosts — use the actual host or IP reachable from the plugin process.

If you restricted the API to specific networks, make sure the address you use here is in the "Local Networks (no username/password)" list under Setup → Settings → Security, otherwise the API call will be rejected.

Power-sensor modes

The plugin computes a signed surplus (positive = exporting) from your configured P1 device(s):

  • Net mode: surplus = -net_value
  • Split mode: surplus = return - usage

In auto mode the boiler setpoint is max(0, min(3500, boiler_watts + surplus)). Because the surplus goes negative as soon as you start importing, the controller automatically backs off instead of getting stuck at 100%.

Control modes

Mode Behaviour
auto Continuously reads the P1 surplus and sends the matching wattage to the boiler.
manual Sends a fixed wattage taken from the Manual Power device.
on Sets the boiler to 100%.
off Sets the boiler to 0% (default on startup).

Switch modes from the Control Mode selector on the device page or via a Domoticz event/script.

Devices created

# Name Type Description
1 Control Mode Selector Switch Off / Auto / Manual / On / Calibrating
2 Manual Power Setpoint (W) Target wattage used in manual mode
3 Calibrate Start Push button Starts a calibration run
4 Calibrate Stop Push button Stops a running calibration
5 Status Alert Running, Idle or Calibrating
6 Device Power kWh (power + energy) Live power draw + cumulative energy
7 Heating Percentage Custom (%) Output percentage reported by the BC
8 Device Temperature Temperature External temperature sensor (I/O)
9 WiFi RSSI Custom (dBm) Wi-Fi signal strength
10 Firmware Version Text BC firmware version
11 IP Address Text IP address of the BC
12 Last Control Update Text Timestamp of the last command sent to the BC

Calibration

Run the calibration sweep once so the BC knows how many watts correspond to each output percentage. The result is stored on the device itself.

  1. Press the Calibrate Start push button on the BC hardware page.
  2. The Status device switches to Calibrating and the Control Mode selector moves to Calibrating while the sweep runs.
  3. When the sweep finishes the plugin restores the previous control mode automatically.

Press Calibrate Stop to abort a running calibration.

Before you start a manual calibration:

  • The boiler must be cooled down. If it is already at temperature the heating element cannot reach the higher setpoints and the curve will be incomplete.
  • The sweep takes at least 6 minutes while it measures every percentage point against the actual wattage.
  • Running it manually is optional — the controller will calibrate itself automatically over time. Use the button only when you want an immediate, complete curve.

How it works

The plugin spawns its own background thread that, every poll_interval seconds:

  1. Fetches GET /api/status and GET /api/system and updates the Domoticz devices.
  2. Applies the current Control Mode:
    • offPOST /api/control {"percentage": 0}
    • onPOST /api/control {"percentage": 100}
    • manualPOST /api/control {"watts": <manual_power>}
    • auto → reads the P1 surplus through the Domoticz JSON API and sends max(0, min(3500, boiler_watts + surplus)) to the BC.

Calibration runs in a separate thread that calls POST /api/calibration/run and polls GET /api/calibration until the run finishes. During calibration the control mode is temporarily locked; when the run ends the previous mode is restored.

Tips

  • Pin Manual Power to your Domoticz dashboard to quickly dial in a fixed wattage.
  • Use Domoticz events or scripts to flip the Control Mode selector, for example on at night on a dynamic tariff and auto during the day.

Example automations (dzVents)

Create these scripts under Setup → More options → Events (script type dzVents). Replace the device names with the ones you used when adding the hardware — by default they are prefixed with the hardware name, e.g. Boiler Controller - Control Mode.

The Control Mode selector accepts these level labels: Off, Auto, Manual, On, Calibrating (don't set Calibrating yourself — that state is managed by the plugin).

Force the boiler on during off-peak hours:

return {
    on = {
        timer = { 'at 23:00' },
    },
    execute = function(domoticz)
        domoticz.devices('Boiler Controller - Control Mode').switchSelector('On')
    end,
}

Return to auto mode in the morning:

return {
    on = {
        timer = { 'at 07:00' },
    },
    execute = function(domoticz)
        domoticz.devices('Boiler Controller - Control Mode').switchSelector('Auto')
    end,
}

Set a fixed wattage manually:

return {
    on = {
        timer = { 'at 12:00' },
    },
    execute = function(domoticz)
        domoticz.devices('Boiler Controller - Manual Power').updateSetPoint(1000)
        domoticz.devices('Boiler Controller - Control Mode').switchSelector('Manual')
    end,
}

React to a price-signal device (example):

return {
    on = {
        devices = { 'Dynamic Tariff Price' },
    },
    execute = function(domoticz, priceDevice)
        local mode = domoticz.devices('Boiler Controller - Control Mode')
        if priceDevice.value < 0.05 then
            mode.switchSelector('On')
        else
            mode.switchSelector('Auto')
        end
    end,
}

Tip: instead of names you can also reference devices by IDX: domoticz.devices(123).switchSelector('Auto'). Use whichever is more stable in your setup.