Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Add Owon PC321 3-phase energy meter support #3274

Open
wants to merge 9 commits into
base: dev
Choose a base branch
from

Conversation

udivankin
Copy link

@udivankin udivankin commented Jul 29, 2024

Another attempt to add Owon PC321 3-phase meter support to ZHA. The meter reports a couple of the standard and a list of non-standard attributes to the Metering cluster.

Proposed change

The proposed quirk maps all reported attributes to OwonManufacturerSpecific custom cluster, and also only supported ones to Metering and ElectricalMeasurement clusters (a separate set of clusters per each of 3 phase-specific endpoints + totals in the main Metering endpoint).

Additional information

Since not all sensors are available in Metering and ElectricalMeasurement clusters for reported attributes, the missing ones will be supported later on in HACS plugin, or alternatively - if corresponding clusters eventually get a full set of sensors natively. But as for now, most users will probably be fine as it is (see screenshot attached)

Fixes #977 #1657
Also, see #2602 for the same device but with different approach (never merged)

Checklist

  • The changes are tested and work correctly
  • pre-commit checks pass / the code has been formatted using Black
  • Tests have been added to verify that the new code works

Screenshot 2024-07-31 at 11 07 41

Another attempt to add Owon PC321 3-phase meter support to ZHA.
The meter reports couple of standart and a list of non-standard attributes to Metering cluster.

This quirk maps all of them to OwonManufacturerSpecific cluster, and also only supported ones to  ElectricalMeasurement cluster.

Since not all sensors are available in Metering and ElectricalMeasurement clusters for reported attributes (e.g. phase-specific consumption figures), the missing ones will be supported later on in HACS plugin.
Copy link

codecov bot commented Jul 29, 2024

Codecov Report

Attention: Patch coverage is 67.16418% with 88 lines in your changes missing coverage. Please review.

Project coverage is 87.60%. Comparing base (e3c115e) to head (6da7692).
Report is 73 commits behind head on dev.

Files with missing lines Patch % Lines
zhaquirks/owon/pc321.py 67.04% 88 Missing ⚠️
Additional details and impacted files
@@            Coverage Diff             @@
##              dev    #3274      +/-   ##
==========================================
- Coverage   88.18%   87.60%   -0.59%     
==========================================
  Files         301      303       +2     
  Lines        9412     9680     +268     
==========================================
+ Hits         8300     8480     +180     
- Misses       1112     1200      +88     

☔ View full report in Codecov by Sentry.
📢 Have feedback on the report? Share it here.


🚨 Try these New Features:

Comment on lines +78 to +81
def __init__(self, *args, **kwargs):
"""Init."""
self._current_state = {}
super().__init__(*args, **kwargs)
Copy link
Collaborator

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

_current_state doesn't seem to be used. If so, this can be removed completely.

Copy link
Collaborator

@TheJulianJES TheJulianJES left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

The Bus stuff isn't needed anymore. You can directly use something like this

self.endpoint.device.endpoints[1].smartenergy_metering.update_attribute(...)

to update attribute cace on another endpoint.

Copy link
Collaborator

@TheJulianJES TheJulianJES left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Also, thanks for the PR, of course.

I think the solution in #2602 might be preferable.
However, it should be converted to a v2 quirk and add custom sensors for the custom attributes (using quirks v2 "exposes").
The entities would also have proper default names in HA then.

(Outdated docs draft PR, but still mostly valid for v2 quirks: #3019)

@udivankin
Copy link
Author

@TheJulianJES Could you please clarify if v2 quirks are already supported? I mean shall I update the current PR with both v1 and v2 quirks or v2 only?

@TheJulianJES TheJulianJES added the help wanted Extra attention is needed label Aug 26, 2024
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
help wanted Extra attention is needed
Projects
None yet
Development

Successfully merging this pull request may close these issues.

[Device Support Request] OWON Technology Inc. PC321,need more information to be displayed