function kappa = pvl_est_kappa_IEC60891_1(IVCurves, aIsc, bVoc)
% PVL_EST_KAPPA_IEC60891_1 estimates the curve correction factor kappa for
% IEC 60891 method 1.
%
% Syntax
% kappa = pvl_est_kappa_IEC60891_1(IVCurves, aIsc, bVoc)
%
% Description
% Methods in IEC60891 translates a point on an IV curve measured at
% irradiance G1 and cell temperature Tc1 to the corresponding point on an
% unobserved IV curve at irradiance G2 and cell temperature Tc2. The
% translation reduces the voltage value by a voltage drop across the
% ‘internal series resistance’ of the module ([IEC 60891], Eq. 2). A value
% for the curve correction factor interpreted as the temperature coefficient
% of the series resistance is found by interative search using a set of
% IV curves measured at different cell temperatures and at a common irradiance:
% first, voltage and current for each IV curve are translated to a common
% temperature, then kappa is found by minimizing the variance of
% Pmp of the translated IV curves.
%
% pvl_est_kappa_IEC60891_1 assumes that the IV curves have been translated
% to a common irradiance.
%
% Input:
% IVCurves - A structure array with the following fields:
% IVCurves.Isc - short circuit current in amperes.
% IVCurves.Voc - open circuit voltage in volts.
% IVCurves.Imp - current at maximum power point in amperes.
% IVCurves.Vmp - voltage at maximum power point in volts.
% IVCurves.Pmp - power at maximum power point in watts.
% IVCurves.V - vector of voltage in volts.
% IVCurves.I - vector of current in amperes.
% IVCurves.Ee - Effective irradiance (W/m2)
% IVCurves.Tc - cell temperature (C)
% aIsc - temperature coefficient for short circuit current in A/C
% bVoc - temperature coefficient for open circuit voltage in V/C
%
% Output:
% kappa - the curve correction factor in ohm/K.
%
% References
% [1] IEC60891 Ed. 2 2009. Procedures for temperature and irradiance
% corrections to measured I-V characteristics of crystalline silicon
% photovoltaic (PV) devices.
%
% [2] C. Hansen and B. King, "Determining series resistance for
% equivalent circuit models of a PV module", in 45th IEEE Photovoltaic
% Specialist Conference, Waikoloa, HI, 2018.
% first check if irradiance levels are all equal
Ee = unique(round([IVCurves(:).Ee], 2));
if length(Ee)>1
warning('est_kappa_IEC60891_1: IV curves must have equal irradiance')
kappa = NaN;
return
else
% find minimum cell temperature
Tc_min = max([IVCurves(:).Tc]);
objfun = @(kappa) max_Pmp_diff(kappa, IVCurves, Ee, Tc_min, aIsc, bVoc);
options = optimset('TolX', 1e-6);
kappa = fminsearch(objfun, 0.0, options);
['Estimated kappa : ' num2str(kappa) ', variance ' num2str(max_Pmp_diff(kappa, IVCurves, Ee, Tc_min, aIsc, bVoc))];
end
function val = max_Pmp_diff(kappa, IVCurves, G, Tc, aIsc, bVoc)
% calculates maximum absolute difference in Pmp after translating IVCurves
% to the highest irradiance
for i=1:length(IVCurves)
tmpIVCurves(i) = pvl_translate_IV_curve_IEC60891_1(IVCurves(i), G, Tc, aIsc, bVoc, 0, kappa);
end
Pmp = [tmpIVCurves(:).Pmp];
val = max(abs((Pmp - median(Pmp))./median(Pmp)));