-
Notifications
You must be signed in to change notification settings - Fork 125
/
gos7.go
227 lines (220 loc) · 7 KB
/
gos7.go
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
package gos7
// Copyright 2018 Trung Hieu Le. All rights reserved.
// This software may be modified and distributed under the terms
// of the BSD license. See the LICENSE file for details.
import (
"fmt"
"strconv"
)
// S7Error implements error interface.
type S7Error struct {
High byte
Low byte
}
// Packager specifies the communication layer.
type Packager interface {
//reserve for future use
Verify(request []byte, response []byte) (err error)
}
// ProtocolDataUnit (PDU) is independent of underlying communication layers.
type ProtocolDataUnit struct {
Data []byte
}
//NewProtocolDataUnit ProtocolDataUnit Constructor
func NewProtocolDataUnit(data []byte) ProtocolDataUnit {
pdu := ProtocolDataUnit{Data: data}
return pdu
}
// Transporter specifies the transport layer.
type Transporter interface {
Send(request []byte) (response []byte, err error)
}
// Error converts known s7 exception code to error message.
func (e *S7Error) Error() string {
/* CPU tells there is no peripheral at address */
errMsg := int(e.High)*256 + int(e.Low)
message := "UNKNOWN ERROR: " + strconv.Itoa(errMsg)
switch errMsg {
case 65487:
message = "API function called with an invalid parameter"
case 65535:
message = "timeout, check RS232 interface"
case 56321:
message = "maybe invalid BCD code or Invalid time format"
case 61185:
message = "wrong ID2, cyclic job handle"
case 54278:
message = "information doesn’t exist"
case 54281:
message = "diagnosis: DP Error"
case 55298:
message = "this job does not exist"
case 53824:
message = "coordination rules were violated"
case 53825:
message = "protection level too low"
case 53826:
message = "protection violation while processing F-blocks; F-blocks can only be processed after password input"
case 54273:
message = "invalid SSL ID"
case 54274:
message = "invalid SSL index"
case 53409:
message = "Step7: function is not allowed in the current protection level."
case 53761:
message = "syntax error: block name"
case 53762:
message = "syntax error: function parameter"
case 53763:
message = "syntax error: block type"
case 53764:
message = "no linked data block in CPU"
case 53765:
message = "object already exists"
case 53766:
message = "object already exists"
case 53767:
message = "data block in EPROM"
case 53769:
message = "block doesn’t exist"
case 53774:
message = "no block available"
case 53776:
message = "block number too large"
case 34048:
message = "wrong PDU (response data) size"
case 34562:
message = "Not address"
case 53250:
message = "Step7: variant of command is illegal."
case 53252:
message = "Step7: status for this command is illegal."
case 33537:
message = "not enough memory on CPU"
case 33794:
message = "maybe CPU already in RUN or already in STOP"
case 33796:
message = "serious error"
case 32768:
message = "interface Is busy"
case 32769:
message = "not permitted in this mode"
case 33025:
message = "hardware error"
case 33027:
message = "access to object not permitted"
case 33028:
message = "Not context"
case 33029:
message = "address invalid. This may be due to a memory address that is not valid for the PLC"
case 33030:
message = "data type not supported"
case 33031:
message = "data type not consistent"
case 33034:
message = "object doesn’t exist. This may be due to a data block that doesn’t exist in the PLC"
case 800:
message = "hardware error"
case 897:
message = "hardware error"
case 16385:
message = "communication link unknown"
case 16386:
message = "communication link not available"
case 16387:
message = "MPI communication in progress"
case 16388:
message = "MPI connection down; this may be due to an invalid MPI address (local or remote ID) or the PLC is not communicating on the MPI network"
case 512:
message = "unknown error"
case 513:
message = "wrong interface specified"
case 514:
message = "too many interfaces"
case 515:
message = "interface already initialized"
case 516:
message = "interface already initialized with another connection"
case 517:
message = "interface not initialized; this may be due to an invalid MPI address (local or remote ID) or the PLC is not communicating on the MPI network"
case 518:
message = "can’t set handle"
case 519:
message = "data segment isn’t locked"
case 521:
message = "data field incorrect"
case 770:
message = "block size is too small"
case 771:
message = "block boundary exceeded"
case 787:
message = "wrong MPI baud rate selected"
case 788:
message = "highest MPI address is wrong"
case 789:
message = "address already exists"
case 794:
message = "not connected to MPI network"
case 795:
message = "-"
case 1:
/* CPU tells there is no peripheral at address */
message = "No data from I/O module" //"hardware fault"
case 3:
/* means a a piece of data is not available in the CPU, e.g. */
/* when trying to read a non existing DB or bit bloc of length<>1 */
/* This code seems to be specific to 200 family. */
message = "object access not allowed: occurs when access to timer and counter data type is set to signed integer and not BCD"
case 4:
message = "Not context"
case 5:
/* means the data address is beyond the CPUs address range */
message = "the desired address is beyond limit for this PLC" //"address out of range: occurs when requesting an address within a data block that does not exist or is out of range"
case 6:
/* CPU tells it does not support to read a bit block with a */
/* length other than 1 bit. */
message = "the CPU does not support reading a bit block of length<>1" //"address out of range"
case 7:
/* means the write data size doesn't fit item size */
message = "Write data size error" //"write data size mismatch"
case 10:
/* means a a piece of data is not available in the CPU, e.g. */
/* when trying to read a non existing DB */
message = "the desired item is not available in the PLC" //"object does not exist: occurs when trying to request a data block that does not exist"
case 257:
message = "communication link not available"
case 266:
message = "negative acknowledge / time out error"
case 268:
message = "data does not exist or is locked"
case -123:
/* PDU is not understood by libnodave */
message = "cannot evaluate the received PDU"
case -124:
message = "the PLC returned a packet with no result data"
case -125:
message = "the PLC returned an error code not understood by this library"
case -126:
message = "this result contains no data"
case -127:
message = "cannot work with an undefined result set"
case -128:
message = "Unexpected function code in answer"
case -129:
message = "PLC responds with an unknown data type"
case -130:
message = "No buffer provided"
case -131:
message = "Function not supported for S5"
// case -132:
// case -133:
// case -134:
case -1024:
message = "Short packet from PLC"
case -1025:
message = "Timeout when waiting for PLC response"
default:
message = "UNKNOWN ERROR: " + strconv.Itoa(errMsg)
}
return fmt.Sprintf("S7: exception (%s)'", message)
}