Model codes
This page contains known information about model codes and static fields, reported by FC command and others.
Protocol version should be written with the known version numbers (determined using commands F8 and FY00), unless the readings signal a yet unknown version. All other results except G2 should be written with their returned ASCII value in the same order they are received (even though output is commonly interpreted with the string reversed). G2 should be noted with its hexadecimal notation instead.
| Indoor Model | Outdoor Model | Protocol version | GC | M | V | G2 | GK | GT | Notes |
|---|---|---|---|---|---|---|---|---|---|
| ATX20K2V1B | 2 | 0000 | |||||||
| FTXF20D5V1B | 3.20 | 135D | |||||||
| CTXM25RVMA | 2 (3.20 ?) | 0EB0 | |||||||
| CTXM35RVMA | 2 (3.20 ?) | 0EB1 | |||||||
| CTXM60RVMA | 2 (3.20 ?) | 0EB4 | |||||||
| S22ZTES-W | 3.0 | 1A01 | MFFFF | V00A0 | 34:3A:80:80 | ||||
| FVXM25 | 3.20 | 0EC3 | |||||||
| FTHF35VAVMB | 2 | 1353 | |||||||
| ATXM25A5V1B | 3.20 (pv=2, cpv=3, cpv_minor=20) | 1770 | |||||||
| FTHF35VAVMB | 2 | 1353 | |||||||
| FTXZ25N | 1? ("F8" 30 31 00 00) |
A2A0 | M10D3 | V00E0 | 3C:3B:00:92 | NAK | NAK | ||
| FTXC24AXVJU | RXC24AXVJU | 2 | C66B0 | M1344 | NAK | 34:3A:00:80 | K0050 | T1000 | @sstanfield, RzB2 and RzC3 NAK'd |
| FTXB25C2V1B | RXB35C2V1B | 0 | NAK | M6082 | V0001 | 34:3A:00:00 | NAK | NAK | @Skdnn-read, RzB2 is always 0 and RzC3 is a nonstandard format (0x4E toggles to 0x4F every ~10s) |
| CTXS07LVJU FTXS12LVJU FTXS15LVJU |
4MXL36TVJU | 0 | NAK | M3E53 | V00C0 | 3D:3B:00:80 | NAK | NAK | @asund |
| FTXS12LVJU | 2MXS18NMVJUA | 0 | NAK | M3E53 | V00C0 | 3D:3B:00:80 | NAK | NAK | @sm-Fifteen, reference for a lot of documented v0 behavior |
| FTXM28NVLT | RXM28MVLT | 0 | M4E53 | @tsunglung | |||||
| CDK50HVE CDK60HVE |
? (F8 and FY00 NAK'd) | NAK | NAK | V400 | 34:32:00:00 | @woeiwen, slim-duct units from ~2002 |
Protocol v1 models, supporting "Humidity" operation mode:
"097A", "097B", "097C", "097D", "097E", "0980", "0981", "0982", "0983", "0984", "0985", "0986", "0987", "0988", "09B5", "09BC", "09BD", "09BE", "09BF", "09C0", "09C1", "09C2", "09C3", "09C4", "0A12", "0A13"
The app uses a hardcoded list, supposedly due to missing optional features information, normally reported by F2 command.
Here is the model number nomenclature Daikin uses outside Japan for residential single-zone and multi-zone indoor units, for reference, in case any of the above fields correlate with information from the model numbers.
| Section | Example | Known values |
|---|---|---|
| Unit category + Product type | FT | F: Air-cooled split indoor unit FT: Wall-mounted FD: Slim-duct FV: Floor-standing FF: Ceiling Cassette, 2'x2' FC: Ceiling Cassette, 3'x3' C: Multi-system CT: Wall-mounted (multi-only) CD: Slim-duct (multi-only) |
| System type | X | K: Inverter, Cooling only X: Inverter, Heatpump V: Non-inverter, Cooling only R: Ceiling Cassette, Cooling only Q: Ceiling Cassette, Heatpump C: Ceiling Cassette, Non-inverter, Cooling only |
| Classification/Efficiency level | S | _: R-410A, "Mid" (blank) N: R-410A, Standard S: R-410A, High G: R-410A, Greatest F: R-32, Standard/"Mid" C: R-32, "Base" M: R-32, High B: "Designed Model" (FTXB-B, ENTRA) Z: R-32, Ururu-Sarara? (FTXZ-N) R: R-410, Ururu-Sarara? (FTXR-E, but EMURA is FTXR-W or FTXR-T) |
| Nominal capacity | 09 | Cooling capacity in thousands of BTU/hr or hecto-watts, depending on region |
| Series/Revision/Generation/Major design category | NM | |
| Power supply | VJ | VJ: 208/230V, 1-phase, 60 Hz V1: 240V, 1-phase, 50 Hz VM: ??? |
| Standard compatibility | U | U: United States (includes Canada) A: ??? B: United Kingdom? |
Sources:
- Daikin US general product catalog, which has most of the nomenclature explained on page 13
- Engineering data sheets and technical manuals for some models, like the FTXB-B, FTX-A and FFRN-C, which break down their own model number.