bpo-39010: Improve test shutdown (#22066)
Browse files Browse the repository at this point in the history
Simply closing the event loop isn't enough to avoid warnings. If we
don't also shut down the event loop's default executor, it sometimes
logs a "dangling thread" warning.

Follow-up to GH-22017
  • Loading branch information
bdarnell authored Sep 3, 2020
1 parent 0770ad9 commit be435ae
Showing 1 changed file with 11 additions and 3 deletions.
14 changes: 11 additions & 3 deletions Lib/test/test_asyncio/test_windows_events.py
Original file line number Diff line number Diff line change
Expand Up @@ -225,10 +225,18 @@ def test_read_self_pipe_restart(self):
self.loop.run_forever()
self.loop.stop()
self.loop.run_forever()
# If we don't wait for f to complete here, we may get another
# warning logged about a thread that didn't shut down cleanly.

# Shut everything down cleanly. This is an important part of the
# test - in issue 39010, the error occurred during loop.close(),
# so we want to close the loop during the test instead of leaving
# it for tearDown.
#
# First wait for f to complete to avoid a "future's result was never
# retrieved" error.
self.loop.run_until_complete(f)
self.loop.close()
# Now shut down the loop itself (self.close_loop also shuts down the
# loop's default executor).
self.close_loop(self.loop)
self.assertFalse(self.loop.call_exception_handler.called)