Skip to content

Commit d0abd17

Browse files
committed
Typo
1 parent 3a02b20 commit d0abd17

File tree

5 files changed

+23
-25
lines changed

5 files changed

+23
-25
lines changed

_wiki/frequency-containment-reserves.md

Lines changed: 3 additions & 4 deletions
Original file line numberDiff line numberDiff line change
@@ -1,14 +1,13 @@
11
---
2-
title: Frequency Restoration Reserves
3-
description: The active power reserves available to restore system frequency to the nominal frequency
2+
title: Frequency Containment Reserves
3+
description: The active power reserves available to contain system frequency after the occurrence of an imbalance.
44
tags:
55
- frequency-control
66
- reserve
77
- european-union
88
- europe
99
related:
1010
- contingency-reserve
11-
- frequency-containment-reserves
1211
- frequency-restoration-reserves
1312
- replacement-reserves
1413
authors:
@@ -24,4 +23,4 @@ generated: 2025-11-28
2423

2524
Source: <d-cite key="eu2017guideline"></d-cite> p5
2625

27-
> ‘frequency restoration reserves’ or ‘FRR’ means the active power reserves available to restore system frequency to the nominal frequency and, for a synchronous area consisting of more than one LFC area, to restore power balance to the scheduled value
26+
> ‘frequency containment reserves’ or ‘FCR’ means the active power reserves available to contain system frequency after the occurrence of an imbalance.

_wiki/frequency-restoration-reserves.md

Lines changed: 4 additions & 4 deletions
Original file line numberDiff line numberDiff line change
@@ -1,14 +1,14 @@
11
---
2-
title: Frequency Containment Reserves
3-
description: The active power reserves available to contain system frequency after the occurrence of an imbalance.
2+
title: Frequency Restoration Reserves
3+
description: The active power reserves available to restore system frequency to the nominal frequency
44
tags:
55
- frequency-control
66
- reserve
77
- european-union
88
- europe
99
related:
1010
- contingency-reserve
11-
- frequency-restoration-reserves
11+
- frequency-containment-reserves
1212
- replacement-reserves
1313
authors:
1414
- name: Jinning Wang
@@ -23,4 +23,4 @@ generated: 2025-11-28
2323

2424
Source: <d-cite key="eu2017guideline"></d-cite> p5
2525

26-
> ‘frequency containment reserves’ or ‘FCR’ means the active power reserves available to contain system frequency after the occurrence of an imbalance.
26+
> ‘frequency restoration reserves’ or ‘FRR’ means the active power reserves available to restore system frequency to the nominal frequency and, for a synchronous area consisting of more than one LFC area, to restore power balance to the scheduled value

database/build/index.json

Lines changed: 7 additions & 7 deletions
Original file line numberDiff line numberDiff line change
@@ -692,9 +692,9 @@
692692
"updated_at": "2025-11-28"
693693
},
694694
{
695-
"id": "frequency-restoration-reserves",
696-
"title": "Frequency Restoration Reserves",
697-
"summary": "The active power reserves available to restore system frequency to the nominal frequency",
695+
"id": "frequency-containment-reserves",
696+
"title": "Frequency Containment Reserves",
697+
"summary": "The active power reserves available to contain system frequency after the occurrence of an imbalance.",
698698
"tags": [
699699
"frequency-control",
700700
"reserve",
@@ -746,9 +746,9 @@
746746
"updated_at": "2025-06-22"
747747
},
748748
{
749-
"id": "frequency-containment-reserves",
750-
"title": "Frequency Containment Reserves",
751-
"summary": "The active power reserves available to contain system frequency after the occurrence of an imbalance.",
749+
"id": "frequency-restoration-reserves",
750+
"title": "Frequency Restoration Reserves",
751+
"summary": "The active power reserves available to restore system frequency to the nominal frequency",
752752
"tags": [
753753
"frequency-control",
754754
"reserve",
@@ -1787,5 +1787,5 @@
17871787
"updated_at": "2025-11-02"
17881788
}
17891789
],
1790-
"generated_at": "2025-11-29T04:10:55Z"
1790+
"generated_at": "2025-11-29T04:18:08Z"
17911791
}

database/json/frequency-containment-reserves.json

Lines changed: 4 additions & 5 deletions
Original file line numberDiff line numberDiff line change
@@ -1,8 +1,8 @@
11
{
22
"$schema": "https://ps-wiki.github.io/schema/v1/term.schema.json",
3-
"id": "frequency-restoration-reserves",
4-
"title": "Frequency Restoration Reserves",
5-
"description": "The active power reserves available to restore system frequency to the nominal frequency",
3+
"id": "frequency-containment-reserves",
4+
"title": "Frequency Containment Reserves",
5+
"description": "The active power reserves available to contain system frequency after the occurrence of an imbalance.",
66
"language": "en",
77
"tags": [
88
"frequency-control",
@@ -12,7 +12,6 @@
1212
],
1313
"related": [
1414
"contingency-reserve",
15-
"frequency-containment-reserves",
1615
"frequency-restoration-reserves",
1716
"replacement-reserves"
1817
],
@@ -39,7 +38,7 @@
3938
"eu2017guideline"
4039
],
4140
"page": "p5",
42-
"body_md": "> ‘frequency restoration reserves’ or ‘FRR’ means the active power reserves available to restore system frequency to the nominal frequency and, for a synchronous area consisting of more than one LFC area, to restore power balance to the scheduled value\n"
41+
"body_md": "> ‘frequency containment reserves’ or ‘FCR’ means the active power reserves available to contain system frequency after the occurrence of an imbalance.\n"
4342
}
4443
]
4544
}

database/json/frequency-restoration-reserves.json

Lines changed: 5 additions & 5 deletions
Original file line numberDiff line numberDiff line change
@@ -1,8 +1,8 @@
11
{
22
"$schema": "https://ps-wiki.github.io/schema/v1/term.schema.json",
3-
"id": "frequency-containment-reserves",
4-
"title": "Frequency Containment Reserves",
5-
"description": "The active power reserves available to contain system frequency after the occurrence of an imbalance.",
3+
"id": "frequency-restoration-reserves",
4+
"title": "Frequency Restoration Reserves",
5+
"description": "The active power reserves available to restore system frequency to the nominal frequency",
66
"language": "en",
77
"tags": [
88
"frequency-control",
@@ -12,7 +12,7 @@
1212
],
1313
"related": [
1414
"contingency-reserve",
15-
"frequency-restoration-reserves",
15+
"frequency-containment-reserves",
1616
"replacement-reserves"
1717
],
1818
"version": "1.0.0",
@@ -38,7 +38,7 @@
3838
"eu2017guideline"
3939
],
4040
"page": "p5",
41-
"body_md": "> ‘frequency containment reserves’ or ‘FCR’ means the active power reserves available to contain system frequency after the occurrence of an imbalance.\n"
41+
"body_md": "> ‘frequency restoration reserves’ or ‘FRR’ means the active power reserves available to restore system frequency to the nominal frequency and, for a synchronous area consisting of more than one LFC area, to restore power balance to the scheduled value\n"
4242
}
4343
]
4444
}

0 commit comments

Comments
 (0)