Skip to content

pchero/sipp-examples

 
 

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

58 Commits
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

SIPp examples

SiPp examples

Introduction

This document provides some step-by-step examples using SIPp in order to emulate different call scenarios.

Directories

  • uac: client examples.
  • uas: server examples.

Requirements:

IMPORTANT: In order to execute all the examples, you will need:

  • A computer with SIPp installed
  • A SIP Proxy (SPLiT or other)
  • One or more Snom phone.
  • A file editor; one with XML syntax highlighting and validation support is preferred
  • A computer equipped with:
    • Ethernet card (10/100 or Gigabit)
    • Supported operating systems: GNU/Linux, Mac OSX > 10.4
    • You must have administrator privileges
    • Wireshark installed
    • SIPp installed (scenario are tested with SIPp v3.5.1 with PCAP and RTPSTREAM features)

How to work with the example code

This document refers to some example scenario that can be found in this repository.

You can clone the repository using the git command: git clone https://github.com/pchero/sipp-examples. Every directory contains a discussed example.

SIPp main features:

SIPp is a tool originally developed to benchmark SIP proxy and UAs. SIPp provides a list of complex features like

  • Builtin scenarios
  • Custom XML-defined scenarios
  • Statistics generation
  • Control channel
  • RTP echo
  • PCAP playback

The tool was originally developed by Hewlett-Packard, now is maintained by an OSS community on Github

Here some important online resources:

Basic concepts

SIPp is a tool capable the send and receive SIP messages, can operate both as a UAC and UAS. The message exchange must be defined in a scenario file.

One of the biggest SIPp limitations is that the tool can handle only one SIP dialog (one Call-ID) in a scenario, however there is some workaround that can be adopted in some situations.

SIPp command line options:

Following a list of the most common command line options. You can obtain the full list executing the command sipp -h.

Scenario options
  • -sn <scenario>: use a builtin scenario (uas, uac, regexp, ...)
  • -sd <scenario>: dump the XML implementing the builtin scenario
  • -sf <scenario-file>: load a custom scenario file
  • -set <var> <val>: set the variable var with val value, the variable can then used into the scenario file as [$var]
SIP IP address and port
  • -i <local_ip>: set the local IP address for the Contact, Via and From headers, can be referenced with [local_ip] keyword into a scenario file. Applies to the SIP protocol only.
  • -p <local_port>: set the local port for the SIP protocol. Can be referenced using the [local_port]keyword.
Media and RTP options
  • -mi <media_ip>: set the local media IP address, this value can also be referred using the [media_ip] keyword into the scenario file
  • -mp <media_port>: set the local media port, this value can also be referred using the [media_port] keyword into the scenario file
  • -rtp_echo: Enable RTP echo. RTP/UDP packets received on port defined by -mp are echoed to their sender.
Call rate options
  • -l <max_calls>: set the maximum number of simultaneous calls
  • -m <calls>: Stop the test and exit when calls calls are processed
Tracing and logging options
  • -trace_msg: dump sent and received SIP messages in <scenario_file_name>_<pid>_messages.log
  • -message_file: Set the name of the message log file
  • -trace_err: trace all unexpected messages in <scenario_file_name>_<pid>_errors.log
  • -error_file: set the name of the error log file
  • -trace_logs: allow tracing of actions in <scenario_file_name>_<pid>_logs.log
  • -log_file: set the name of the log actions log file

SIPp scenario file syntax

  • root XML tag is named scenario and must have the name attribute:

    <?xml version="1.0" encoding="utf-8" ?>
    <scenario name="Basic UAC custom scenario">
      <!-- here your scenario -->
    </scenario>

Scenario commands

Here is a lost of the most important scenario commands:

  • <send>: send a SIP message or a response. Important attributes are:

    • retrans: set the T1 timer for this message in milliseconds
    • lost: emulate packet lost, value in percentage
  • <recv>: wait for a SIP message or response. Important attributes are:

    • response: indicates what SIP message code is expected
    • request: indicates what SIP message request is expected
    • optional: Indicates if the message to receive is optional. If optional is set to "global", SIPp will look every previous steps of the scenario
    • lost: emulate packet lost, value in percentage
    • timeout: specify a timeout while waiting for a message. If the message is not received, the call is aborted
    • ontimeout: specify a label to jump to if the timeout popped regexp_match: boolean. Indicates if 'request' ('response' is not available) is given as a regular expression.

    The recv command can also include the action tag defining the action to execute upon the message reception

  • pause: pause the scenario execution. Important attributes are:

    • milliseconds: time to pause in milliseconds
    • variable: scenario variable defining the pause time
  • nop: the nop action doesn’t do nothing at SIP signalling level, is just a tag containing the action subtag

  • sendCmd: content to be sent to the twin 3PCC (3rd Party Call Control) SIPp instance. The Call-ID must be included

  • recvCmd: specify an action when receiving the command

  • label: a label is used when you want to branch to specific parts in your scenarios

Common command attributes

Here is a list of attributes common to all the scenario commands:

  • crlf: Displays an empty line after the arrow for the message in main SIPp screen
  • next: You can put a "next" in any command element to go to another part of the script when you are done with sending the message. For optional receives, the next is only taken if that message was received
  • test: You can put a "test" next to a "next" attribute to indicate that you only want to branch to the label specified with "next" if the variable specified in "test" is set
  • display: Display a text into the SIPp screen

Scenario keywords

Inside the send command, you have to enclose your SIP message between the <![CDATA and the ]]> tags.

Everything between those tags is going to be sent toward the remote system. Into the SIP message you can include some keywords (Eg. [service], [remote_ip], etc..).

Those keywords will get replaced at runtime by SIPp.

  • [service]: service field, as passed in the -s <service_name> command line option (default: service)
  • [remote_ip] and [remote_port]: remote IP address and port
  • [transport]: the transport mode (depending on the -t CLI parameter) (default: UDP)
  • [local_ip], [local_ip_type], [local_port]: depending on the -l and -p CLI params. Type can be 4 or 6
  • [len]: computed length of the SIP body. To be used in Content-Length header
  • [cseq]: generates automatically the CSeq number
  • [call_id]: a call_id identifies a call and is generated by SIPp for each new call. In client mode, it is mandatory to use the value generated by SIPp in the Call-ID header
  • [media_ip], [media_ip_type], [media_port]: depending on the value of -mi and -mp params.
  • [last_*]: is replaced automatically by the specified header if it was present in the last message received (Eg. [last_From])

Scenario actions

In a recv, recvCmd or nop command you can execute one or more actions:

  • ereg: execute a regular expression matching
  • log: write a log message
  • exec: execute a command on the operating system shell, or an internal SIPp command or play a pcap file
  • jump: jump to an arbitrary scenario index

Creating an UAC scenario

  1. An UAC scenario starts with a send command:

    <?xml version="1.0" encoding="UTF-8" ?>
    <scenario name="Basic UAC scenario">
     <send>
      <![CDATA[  
      INVITE sip:[service]@[remote_ip]:[remote_port] SIP/2.0
      Via: SIP/2.0/[transport] [local_ip]:[local_port]
      From: sipp <sip:sipp@[local_ip]:[local_port]>;tag=[call_number]
      To: sut <sip:[service]@[remote_ip]:[remote_port]>
      Call-ID: [call_id]
      Cseq: 1 INVITE
      Contact: sip:sipp@[local_ip]:[local_port]
      Content-Type: application/sdp
      Content-Length: [len]
      
      v=0
      o=user1 53655765 2353687637 IN IP[local_ip_type] [local_ip]
      s=-
      t=0 0
      c=IN IP[media_ip_type] [media_ip]
      m=audio [media_port] RTP/AVP 0
      a=rtpmap:0 PCMU/8000
      ]]>
     </send>
  2. The scenario waits for an answer: 100 Trying and 180 Ringing are optional. the 200 OK is mandatory.

     <recv response="100" optional="true">
     </recv>
     
     <recv response="180" optional="true">
     </recv>
     
     <recv response="200">
     </recv>
  3. Once the 200 OK is received the scenario sends the ACK and waits for 5 seconds:

     <send>
      <![CDATA[
      ACK sip:[service]@[remote_ip]:[remote_port] SIP/2.0
      Via: SIP/2.0/[transport] [local_ip]:[local_port]
      From: sipp <sip:sipp@[local_ip]:[local_port]>;tag=[call_number]
      To: sut <sip:[service]@[remote_ip]:[remote_port]>[peer_tag_param]
      Call-ID: [call_id]
      Cseq: 1 ACK
      Contact: sip:sipp@[local_ip]:[local_port]
      Content-Length: 0
      ]]>
     </send>
     <pause milliseconds="5000"/>
  4. The scenario terminates sending a BYE and waiting for the 200 OK:

     <send retrans="500">
      <![CDATA[
      BYE sip:[service]@[remote_ip]:[remote_port] SIP/2.0
      Via: SIP/2.0/[transport] [local_ip]:[local_port]
      From: sipp  <sip:sipp@[local_ip]:[local_port]>;tag=[call_number]
      To: sut  <sip:[service]@[remote_ip]:[remote_port]>[peer_tag_param]
      Call-ID: [call_id]
      Cseq: 2 BYE
      Contact: sip:sipp@[local_ip]:[local_port]
      Content-Length: 0
      ]]>
     </send>
     <recv response="200">
     </recv>
    </scenario>

Creating an UAS scenario

  1. An UAS scenario starts with a recv command, the scenario replies with 180 Ringing. The scenario extract the From header value and the Contact SIP URI from the request:

    <?xml version="1.0" encoding="UTF-8" ?>
    <scenario name="Basic UAS scenario">
     <recv request="INVITE">
      
      <action>
       <!-- since we need to send a request to the remote part -->
       <!-- we need to extract the Contact and the From header content -->
       <ereg regexp=".*" search_in="hdr" header="From" assign_to="remote_from"/>
       <!-- assign the content of the Contaact SIP URI to the remote_contact var -->
       <!-- first var of assign_to contains the whole match -->
       <ereg regexp="sip:(.*)>.*" search_in="hdr" header="Contact" assign_to="trash,remote_contact"/>
      </action>
     </recv>
     <!-- since SIPp complains about not used variable reference the trach var -->
     
     <Reference variables="trash"/>
  2. Now the scenario should answer the call with 200 OK and wait for the ACK message:

     <send retrans="500">
      <![CDATA[
      SIP/2.0 200 OK
      [last_Via:]
      [last_From:]
      [last_To:];tag=[pid]SIPpTag01[call_number]
      [last_Call-ID:]
      [last_CSeq:]
      Contact: <sip:[local_ip]:[local_port];transport=[transport]>
      Content-Type: application/sdp
      Content-Length: [len]
      
      v=0
      o=user1 53655765 2353687637 IN IP[local_ip_type] [local_ip]
      s=-
      c=IN IP[media_ip_type] [media_ip]
      t=0 0
      m=audio [media_port] RTP/AVP 0
      a=rtpmap:0 PCMU/8000
      ]]>
     </send>
     <recv request="ACK" optional="true" crlf="true">
     </recv>
  3. To end the call the scenario waits for the BYE and accept it with 200 OK. In case the BYE is not received in 3000 ms the scenario jumps to the send_bye label:

     <recv request="BYE" timeout="3000" ontimeout="send_bye">
     </recv>
     <send>
      <![CDATA[
      SIP/2.0 200 OK
      [last_Via:]
      [last_From:]
      [last_To:]
      [last_Call-ID:]
      [last_CSeq:]
      Contact: <sip:[local_ip]:[local_port];transport=[transport]>
      Content-Length: 0
      ]]>
     </send>
     
     <nop>
      <action>
       <exec int_cmd="stop_now"/>
      </action>
     </nop>
  4. Define the send_bye label:

     <label id="send_bye"/>
  5. Send the BYE and wait for the 200 OK

     <send retrans="500">
      <![CDATA[
      BYE [$remote_contact] SIP/2.0
      Via: SIP/2.0/[transport] [local_ip]:[local_port]
      From: sipp  <sip:sipp@[local_ip]:[local_port]>;tag=[pid]SIPpTag01[call_number]
      To: [$remote_from]
      Call-ID: [call_id]
      Cseq: 2 BYE
      Contact: sip:sipp@[local_ip]:[local_port]
      Content-Length: 0
      ]]>
     </send>
     
     <recv response="200">
     </recv>
    </scenario> 

NOTE: Both UAC and UAS scenario can be found into the Basic folder: Basic/uac.xml and Basic/uas.xml

Specific settings for SIPp and Snom phones

If you want to run and UAC against a Snom phone (calling the phone from SIPp), you should pay attention the following points:

  • disable the filter_registrar unless you are not running the SIPp from the PBX
  • configure the network_id_port unless you don't want to figure out from the phone registration (look at the Contact header sent by the phone during the registration)
  • configure the user_sipusername_as_line unless you don't want to figure out from the phone registration (look at the Contact header sent by the phone during the registration)
  • you should use the -s command line option to define the [service] keyword containing the SIP identity username

If you want to call an UAS scenario from a Snom phone the simplest way is to configure a speed dial function key calling the SIPp scenario, Eg.: fkey3=speed sip:sipp@172.16.18.55:5060, where 172.16.18.55 is the SIPp address and 5060is the SIPp port.

Some sample scenario

SIP Call with re-INVITE

This scenario is quite similar to the basic described before: UAC sends an INVITE containing the SDP offer, once the dialog is established the UAC sends an in-dialog INVITE.

The UAS

Scenario file: reINVITE-PAI/uas.xml

./sipp -sf reINVITE-PAI/uas.xml -i <local_ip> -p <local_port> -m 1

Where:

  • <local_ip> is the local IP address
  • <local_port is the local SIP port

The UAC

Scenario file: reINVITE-PAI/uac-active.xml

sipp -sf reINVITE-PAI/uac-active.xml -m 1 -s <service> -i <local_ip> <remote_ip>:<remote_port>

Where:

  • <local_ip> is the local IP address
  • <remote_ip> is the remote IP address
  • <remote_port> is the remote port
  • is the called service, if you are calling a phone should be username.

Active Media call scenario

The folder Active-Media contains UAS and UAC scenarios for Active media negotiation (SDP offer sent into the INVITE request).

The UAC is responsible for the dialog creation and closure.

The UAS

Scenario file: Active-Media/uas-active.xml

Since the UAS scenario is playing a PCAP file, SIPp should run with a priviledged user.

sudo sipp -sf Active-Media/uas-active.xml -i <local_ip> -p <local_port> -m 1

Where:

  • <local_ip> is the local IP address
  • <local_port is the local SIP port

The UAC

Scenario file: Active-Media/uac-active.xml

sudo sipp -sf Active-Media/uac-active.xml -m 1 -s <service> -i <local_ip> <remote_ip>:<remote_port>

Where:

  • <local_ip> is the local IP address
  • <remote_ip> is the remote IP address
  • <remote_port> is the remote port
  • is the called service, if you are calling a phone should be username.

RTP Echo

If you want to use the RTP echo feature instead of playing a PCAP file you can commend out the section:

  <nop>
    <action>
        <exec play_pcap_audio="../pcap/g711a.pcap"/>
    </action>
  </nop>

and then add the -rtp_echo option to the SIPp command line

Passive Media call scenarios

The folder Passive-Media contains UAS and UAC scenarios for Passive media negotiation (SDP offer sent into the 200 OK).

The UAC is responsible for the dialog creation and closure.

The UAS

Scenario file: Passive-Media/uas-passive.xml

Since the UAS scenario is playing a PCAP file should run with a proviledged user.

sudo sipp -sf Passive-Media/uas-passive.xml -i <local_ip> -p <local_port> -m 1

Where:

  • <local_ip> is the local IP address
  • <local_port is the local SIP port

The UAC

Scenario file: Passive-Media/uac-passive.xml

sudo sipp -sf Passive-Media/uac-passive.xml -m 1 -s <service> -i <local_ip> <remote_ip>:<remote_port>

Where:

  • <local_ip> is the local IP address
  • <remote_ip> is the remote IP address
  • <remote_port> is the remote port
  • is the called service

Hold call scenario (hold from UAC)

The folder Hold-UAC contains UAS and UAC scenarios for call hold using the RFC 3264 specification (a=sendonly/recvonly).

In this scenario the UAC sends the first INVITE, and the hold and retrieve re-INVITEs.

The UAS

Scenario file: Hold-UAC/uas-hold.xml

Since the UAS scenario is playing a PCAP file should run with a proviledged user.

sudo sipp -sf Hold-UAC/uas-hold.xml -i <local_ip> -p <local_port> -m 1

Where:

  • <local_ip> is the local IP address
  • <local_port is the local SIP port

The scenario expects 2 re-INVITE from the UAC (first putting the call on hold and second retrieving the call).

The UAC

Scenario file: Hold-UAC/uac-hold.xml

sudo sipp -sf Hold-UAC/uac-hold.xml -m 1 -s <service> -i <local_ip> <remote_ip>:<remote_port>

Where:

  • <local_ip> is the local IP address
  • <remote_ip> is the remote IP address
  • <remote_port> is the remote port
  • is the called service

Hold call scenario (hold from UAS)

The scenario in the Hold-UAS folder is a little bit different from the previous one: in this case the hold re-INVITE is send by the UAS. For this reason the UAS need to save the original From header and the Contact URI from the UAC request.

The UAS

Scenario file: Hold-UAS/uas-hold.xml

You can run the UAS scenario using the command:

sipp -sf Hold-UAS/uas-hold.xml -i <local_ip> -p <local_port> -m 1

Where:

  • <local_ip> is the local IP address
  • <local_port is the local SIP port

The scenario expects an INVITE from the UAC, after receiving the INVITE the UAS accepts the call and sends a re-INVITE with a=sendonly.

The UAC

Scenario file: Hold-UAS/uac-hold.xml

You can run the UAC scenario using the command:

sipp -sf Hold-UAS/uac-hold.xml -i <local_ip> -s <service> -m 1 <remote_ip>:<remote_port>

Where:

  • <local_ip> is the local IP address
  • <remote_ip> is the remote IP address
  • <remote_port> is the remote port
  • is the called service

UAS MWI notification

Scenario file: MWI-unsolicited/uas-mwi.xml

This scenario accepts an UAC registration, the scenario accepts the REGISTER and then sends some unsolicited NOTIFY containing the MWI notification.

You can run the UAS scenario using the command:

sipp -sf MWI-unsolicited/uas-mwi.xml -i 172.16.18.69 -m 1 -p 5060

Please note that this scenario is using the same Call-ID for the REGISTER reply and the NOTIFY.

To use this scenario with a Snom phone you can configure an identity with SIPp IP address as registrar.

UAS BLF implementing the signalling defined by RFC4235

Scenario file: BLF/uas-blf-recipient.xml

This UAS scenario implements the protocol and syntax described by RFC 4235 defining the BLF functionality

The scenario simulates a monitored SIP entity receiving a call

Executing the scenario

You can execute the scenario running the following command:

  • local_display defines the local display name of the incoming dialog
  • local_identity defines the local identity of incoming dialog
  • local_uri defines the caller URI
  • remote_display defines the remote display name of the incoming dialog
  • remote_identity defines the remote identity of the incoming dialog
  • target_uri defines the remote contact of the incoming dialog

Example:

    sipp -sf BLF/uas-blf-recipient.xml -i 172.16.18.69 -m 1 \
    -key local_display Bob \
    -key local_identity bob@houseofbob:5060 \
    -key local_uri sip:bob@wonderlan.com \
    -key remote_display Carl \
    -key remote_identity carl@carl@houseofcarl:5060 \
    -key target_uri bob@wonderland.com \

Call diagram

A               B                C
|               |                |
|   SUBSCRIBE   |                |
|-------------->|                |
|               |                |
|  202 Accepted |                |
|<--------------|                |
|               |   INVITE       |
|               |<---------------|
|               |                |-+
|               |  180 Ringing   | |
|               |--------------->| |
|  NOTIFY       |                | |
|<--------------|                | | EARLY
|               |                | |
|  200 OK       |                | |
|-------------->|                | |
|               |   200 OK       | |
|               |--------------->|-+
|               |     ACK        | 
|               |<---------------|-+ 
|  NOTIFY       |                | |
|<--------------|                | |
|               |                | |
|  200 OK       |                | | CONNECTED
|-------------->|                | |
|               |     BYE        | |
|               |<---------------|-+
|               |     200 OK     |
|               |--------------->|-+
|  NOTIFY       |                | |
|<--------------|                | | TERMINATED
|               |                | |
|  200 OK       |                | |
|-------------->|                |-+

Note usage with a Snom Phone as UAC: after executing the scenario you should configure a function key as a BLF monitoring the SIPp instance, Eg.: fkey3=blf sipp@172.16.18.69

Call Pickup with 3PCC (Replaces header)

Scenario files: Call-pickup-3pcc/uac-3pcc-C-A.xml and Call-pickup-3pcc/uac-3pcc-C-B.xml

The whole scenario need 2 SIPp instances in communication trough the 3PCC SIPp feature.

  • Call-pickup-3pcc/uac-3pcc-C-A.xml is the scenario controlling the first SIPp instance (A)
  • Call-pickup-3pcc/uac-3pcc-C-B.xml is the scenario controlling the second SIPp instance (B)

The whole scenario can be described with the following steps:

  1. Instance A starts a call with DUT
  2. As soon DUT answers the call, instance B sends a new INVITE containing the Replaces header, the header must contain the Call-ID and the local and remote tags of the first dialog (see the previous point)
  3. Now DUT should terminate the first dialog (replaced by the new one). The caller ID should be updated
  4. DUT should answer the call
  5. Now instance B waits for a BYE from the phone

Message diagram

DUT                         A(uac-3pcc-C-A.xml)                     B(uac-3pcc-C-B.xml)
 |    INVITE                |                                       |
 |<-------------------------|                                       |
 |                          |                                       |
 |    180 Ringing           |                                       |
 |------------------------->|                                       |
 |                          |                                       |
 |                          |  Cmd (Call-ID,local-tag,remote-tag)   |
 |                          |-------------------------------------->|
 |    INVITE (Replaces)     |                                       |
 |<-----------------------------------------------------------------|
 |                          |                                       |
 |     BYE                  |                                       |
 |------------------------->|                                       |
 |                          |                                       |
 |    200 OK                |                                       |
 |<-------------------------|                                       |
 |                          |                                       |
 | 200 OK                   |                                       |
 |----------------------------------------------------------------->|
 |                          |                                       |
 |    BYE                   |                                       |
 |----------------------------------------------------------------->|
 |                          |                                       |
 |    200 OK                |                                       |
 |<-----------------------------------------------------------------|
 |                          |                                       |     

The 3PCC feature is designed to reuse the same Call-ID of the first call (adding the Call-ID header in the sendCmd is mandatory), but in this scenario we need to instantiate a new SIP dialog, for this reason we add the prefix new- into the header value.

How to use

  1. You have to start the SIPp instance B, assuming that:
  • 172.16.18.15 is your computer address
  • you want to receive the messages from instance A to the port 7777
  • 172.16.18.64 is DUT (Device Under Test)
  • 382 is the DUT extension
sipp -p 5061 -sf Call-pickup-3pcc/uac-3pcc-C-B.xml -s 382 -3pcc 127.0.0.1:7777 -i 172.16.18.15 -mi 172.16.18.15 -m 1 172.16.18.64

Once instance started SIPp will wait for the command from instance A

  1. Start the instance A, assuming that:
  • 172.16.18.15 is your computer address
  • you want to send the messages to instance B to the port 7777
  • 172.16.18.64 is DUT
  • 382 is the DUT extension
sipp -p 5062 -sf Call-pickup-3pcc/uac-3pcc-C-A.xml -s 382 -3pcc 127.0.0.1:7777 -i 172.16.18.15 -mi 172.16.18.15 -m 1 172.16.18.64
  1. At this point DUT should ring, once you answer the call instance A should exit and the call should be terminated on instance B

NOTE: if DUT is a Snom phone and you want to automate the call answer last point you can de-comment the following action:

  <nop display="Remotely answering pressing the ENTER key">
   <action>
     <exec command="curl -s http://[remote_ip]/command.htm?key=ENTER > /dev/null"/>
   </action>
  </nop>

Releases

No releases published

Packages

No packages published

Languages

  • HTML 71.4%
  • CSS 24.1%
  • JavaScript 4.4%
  • Other 0.1%