#Example fan zone definitions for phosphor-fan-control
#List the properties of the fan zones that are possible in the system.
#The zones may be conditional based on certain conditions, such as
#different chassis types or water cooled models. The fans themselves
#are not listed in this file. They are in a separate YAML file so it
#can be machine generated (i.e. from the MRW) if desired.
#The general structure is a list of groups of zones, where a group
#contains both the zones and the conditions required for the zones
#to be valid
#The cooling_profile is used along with the zone number to know
#which fans in the fan yaml belong in this zone instance. For
#example, a fan may only be in zone 0 if it's the air cooled version
#of the system, but not with the water cooled version. In that
#case, the fan yaml would have a cooling_profile of 'air' to match
#the zone cooling profile.
#manager_configuration:
# power_on_delay: [Number of seconds that phosphor-fan-control --init
# should delay after setting fans to full speed on
# a power on.]
#
#zone_configuration:
# - zone_conditions:
# - name: [Name of a condition, if any.]
#
# zones:
# - zone: [zone number]
# cooling_profiles:
# - [cooling profile]
# full_speed: [Full speed for the zone.]
# default_floor: [Default floor speed for the zone that fan speeds can
# not go below.]
# increase_delay: [Number of seconds to delay additional speed increases
# that are less than the speed increase that's currently
# occurring.]
# decrease_interval: [A repeating number of seconds interval that
# requested speed decreases may occur when no speed
# increase is occurring at that time as well.]
#Example:
#manager_configuration:
# power_on_delay: 20
#
#zone_configuration:
# - zone_conditions:
# - name: air_cooled_chassis
#
# zones:
# - zone: 0
# cooling_profiles:
# - air
# - all
# full_speed: 10500
# default_floor: 6000
# increase_delay: 5
# decrease_interval: 30
#
# - zone_conditions:
# - name: water_and_air_cooled_chassis
#
# zones:
# - zone: 0
# cooling_profiles:
# - water
# - all
# full_speed: 4000
# default_floor: 2500
# increase_delay: 5
# decrease_interval: 20