Sample PROTOCOL acquisition from a Vendor Model.
-
Generate DICOM preview:
Update preview.py with the absolute path to your local directory and run using MRIcroGL (Scripting ⇾ Open). Validate that preview.png was created and remove preview.py.
-
Generate NIfTI preview:
[View NIfTI in NiiVue](https://niivue.github.io/niivue/features/view.html?url=https://.github.io//nii/converted.nii.gz)
This table may be extended with other modality or institution information.
Tag | Name | Value |
---|---|---|
(0008, 0060) | Modality | "MODALITY" |
(0008, 0070) | Manufacturer | "MANUFACTURER" |
(0008, 0080) | Institution Name | "Some Institution" |
(0008, 1090) | Manufacturer's Model Name | "Model" |
(0018, 1020) | Software Versions | "Ver. Info E01" |
Other vendor/modality/encoding-specific information should be included here.
Any comments regarding the patient should be included here.
Tag | Name | Value |
---|---|---|
(0010, 0010) | Patient's Name | "Doe^John" |
(0010, 0020) | Patient ID | "0123" |
(0010, 0030) | Patient's Birth Date | "19500101" |
(0010, 0040) | Patient's Sex | "M" |
(0010, 1010) | Patient's Age | "070Y" |
(0010, 1020) | Patient's Size | "1.80" |
(0010, 1030) | Patient's Weight | "70.0" |
Any comments regarding series acquisition should be included here.
Tag | Name | Value |
---|---|---|
(0008, 0021) | Series Date | "20200101" |
(0008, 0031) | Series Time | "100000.000000" |
(0008, 103E) | Series Description | "series_description" |
Modality-specific acquisition parameters should be included here, e.g. for MR sequences the following may be included:
Tag | Name | Value |
---|---|---|
(0018, 0015) | Body Part Examined | "BRAIN" |
(0018, 0020) | Scanning Sequence | ["AB", "CD"] |
(0018, 0021) | Sequence Variant | ["EF", "GH", "IJ"] |
(0018, 0022) | Scan Options | "KL" |
(0018, 0023) | MR Acquisition Type | "3D" |
(0018, 0024) | Sequence Name | "name" |
(0018, 0025) | Angio Flag | "N" |
(0018, 0050) | Slice Thickness | "1.0" |
(0018, 0080) | Repetition Time | "1000.0" |
(0018, 0081) | Echo Time | "1.0" |
(0018, 0082) | Inversion Time | "50.0" |
(0018, 0091) | Echo Train Length | "1" |
(0018, 0093) | Percent Sampling | "100.0" |
(0018, 0094) | Percent Phase Field of View | "100.0" |
(0018, 0095) | Pixel Bandwidth | "100.0" |
(0018, 1310) | Acquisition Matrix | [100, 0, 0, 100] |
(0018, 1312) | In-plane Phase Encoding Direction | "COL" |
(0018, 1314) | Flip Angle | "1.0" |
(0018, 5100) | Patient Position | "HFS" |
(0028, 0010) | Rows | 100 |
(0028, 0011) | Columns | 100 |
(0028, 0030) | Pixel Spacing | [1, 1] |