-- clk_count_max = (Frequency of clk)/(Frequency of UART)
-- Example: 100 MHz Clock, 115200 baud UART
-- (100000000)/(115200) = 870
-- Example: 100 MHz Clock, 9600 baud UART
-- (100000000)/(9600) = 10416.666~10417
library ieee;
use ieee.std_logic_1164.all;
entity UART_transmitter is
generic (
clk_count_max : integer := 870 ); -- Needs to be set correctly
port (
clk,start : in std_logic;
data : in std_logic_vector(7 downto 0);
transmit : out std_logic := '1';
active, done : out std_logic := '0');
end UART_transmitter;
architecture U of UART_transmitter is
type sequence is (waiting, bits, finish);
signal seq : sequence := waiting;
signal clk_count : integer range 0 to clk_count_max-1 := 0;
signal bit_index : integer range 0 to 9 := 0;
signal loaded_data : std_logic_vector(9 downto 0) := "1UUUUUUUU0"; -- "stop bit, 8 data bits, start bit"
begin
process (clk)
begin
if rising_edge(clk) then
case seq is
when waiting =>
active <= '0';
transmit <= '1';
done <= '0';
clk_count <= 0;
bit_index <= 0;
loaded_data <= "1UUUUUUUU0";
if start='1' then
loaded_data(8 downto 1) <= data;
seq <= bits;
end if;
when bits =>
active <= '1';
transmit <= loaded_data(bit_index);
if clk_count >= clk_count_max-1 then
if bit_index >= 9 then
done <= '1';
clk_count <= 0;
seq <= finish;
else
bit_index <= bit_index + 1;
clk_count <= 0;
end if;
else
clk_count <= clk_count + 1;
end if;
when finish =>
active <= '0';
done <= '1';
seq <= waiting;
when others =>
seq <= waiting;
end case;
end if;
end process;
end U;