# micropython
# ВНИМАНИЕ: не подключайте питание датчика к 5В, иначе датчик выйдет из строя! Только 3.3В!!!
# WARNING: do not connect "+" to 5V or the sensor will be damaged!
from machine import I2C
import bmp180
import time
from sensor_pack.bus_service import I2cAdapter
def pa_mmhg(value: float) -> float:
"""Convert air pressure from Pa to mm Hg"""
return value*7.50062E-3
if __name__ == '__main__':
# пожалуйста установите выводы scl и sda в конструкторе для вашей платы, иначе ничего не заработает!
# please set scl and sda pins for your board, otherwise nothing will work!
# https://docs.micropython.org/en/latest/library/machine.I2C.html#machine-i2c
# i2c = I2C(0, scl=Pin(13), sda=Pin(12), freq=400_000) # для примера
# bus = I2C(scl=Pin(4), sda=Pin(5), freq=100000) # на esp8266 !
# Внимание!!!
# Замените id=1 на id=0, если пользуетесь первым портом I2C !!!
# Warning!!!
# Replace id=1 with id=0 if you are using the first I2C port !!!
adaptor = I2cAdapter(I2C(1, freq=400_000))
# ps - pressure sensor
ps = bmp180.Bmp180(adaptor)
# если у вас посыпались исключения EIO, то проверьте все соединения.
# if you have EIO exceptions, then check all connections.
res = ps.get_id()
print(f"chip_id: {hex(res)}")
print("Calibration data from registers:")
print([ps.get_calibration_data(i) for i in range(11)])
print(20 * "*_")
print("Reading temperature in a cycle.")
for i in range(333):
ps.start_measurement(temperature_or_pressure=True) # switch to temperature
delay = bmp180.get_conversion_cycle_time(ps.temp_or_press, ps.oversample)
time.sleep_ms(delay) # delay for temperature measurement
print(f"Temperature from BMP180: {ps.get_temperature()} \xB0 С\tDelay: {delay} [ms]")
ps.start_measurement(temperature_or_pressure=False) # switch to pressure
delay = bmp180.get_conversion_cycle_time(ps.temp_or_press, ps.oversample)
time.sleep_ms(delay) # delay for pressure measurement
print(20 * "*_")
print("Reading pressure using an iterator!")
for index, press in enumerate(ps):
time.sleep_ms(delay) # delay for pressure measurement
ps.start_measurement(temperature_or_pressure=False)
print(f"Pressure from BMP180: {press} Pa\t{pa_mmhg(press)} mm Hg\tDelay: {delay} [ms]")