Skip to content

buffer: inconsistencies in readIntBE() and readIntLE() #10515

Closed
@Trott

Description

  • Version: 7.3.0
  • Platform: OS X 10.12.2
  • Subsystem: buffer

The documentation for readIntLE() and readIntBE() both indicate that the second argument (byteLength) is required. However, both functions will seem to operate without a byteLength provided. Unfortunately, byteLength will default to 0 in that case, which results in unpredictable behavior:

> var buf = Buffer.from([126, 127, 128, 129, 130])
undefined
> buf.readIntLE(0)
126
> buf.readIntBE(0)
undefined
> buf.readIntBE(4)
128
> buf.readIntLE(4)
129
>

Perhaps we should do one of the following?:

  • have byteLength default to 1 rather than 0
  • throw an error if byteLength is not provided
  • warn in the documentation that if you fail to provide byteLength, then you will get a result but there are no guarantees even about the return value type