@yarikoptic
Copy link
Member

Not yet sure if might be reproin heuristic specific. ATM for SE sequences intended to be pepolar fieldmaps https://bids-specification.readthedocs.io/en/stable/04-modality-specific-files/01-magnetic-resonance-imaging-data.html#case-4-multiple-phase-encoded-directions-pepolar we are getting files with _magnitude suffix, whenever it should be _epi.

Attn @amanelis17

@pvelasco
Copy link
Contributor

pvelasco commented Jul 3, 2019

Hi @yarikoptic,

Yes, it looks like the problem is with the reproin heuristic file. The pepolar fieldmaps are magnitude images, so they have the M label in the s.image_type and reproin will assign the seqtype_label magnitude.
What we do in our heuristic file is we also check the s.sequence_name: epse2d is for the pepolar fieldmaps, while the traditional GRE fieldmaps s.sequence_name is fm2d. (NB: This is for a Siemens Prisma)
So, I would do something like this:

if seqtype == 'fmap' and not seqtype_label:
    if 'fm2d' in s.sequence_name:
        if not dcm_image_iod_spec:
            raise ValueError("Do not know image data type yet to make decision")
        seqtype_label = {
            'M': 'magnitude',  # might want explicit {file_index}  ?
            'P': 'phasediff',
            'DIFFUSION': 'epi', # according to KODI those DWI are the EPIs we need
        }[dcm_image_iod_spec]
    else:
        seqtype_label = 'epi'     # (or whichever label you want to give it).

For other scanner vendors, you will need to check the sequence_name for the GRE fieldmaps and include them in the new if statement.

I hope this helps.

@yarikoptic
Copy link
Member Author

THANK YOU @pvelasco ! I think in our (reproin) case we could judge based on having _dir- field present, which is defined/makes sense only for pepolar ones and not for generic fieldmaps

yarikoptic added a commit that referenced this issue Dec 16, 2019
This is largely a bug fix.  Metadata and order of `_key-value` fields in BIDS
could change from the result of converting using previous versions, thus minor
version boost.
14 people contributed to this release -- thanks
[everyone](https://github.com/nipy/heudiconv/graphs/contributors)!

 Enhancement

- Use [etelemetry](https://pypi.org/project/etelemetry) to inform about most
  recent available version of heudiconv. Please set `NO_ET` environment variable
  if you want to disable it ([#369][])
- BIDS:
  - `--bids` flag became an option. It can (optionally) accept `notop` value
    to avoid creation of top level files (`CHANGES`, `dataset_description.json`,
    etc) as a workaround during parallel execution to avoid race conditions etc.
    ([#344][])
  - Generate basic `.json` files with descriptions of the fields for
    `participants.tsv` and `_scans.tsv` files ([#376][])
  - Use `filelock` while writing top level files. Use
    `HEUDICONV_FILELOCK_TIMEOUT` environment to change the default timeout value
    ([#348][])
  - `_PDT2` was added as a suffix for multi-echo (really "multi-modal")
    sequences ([#345][])
- Calls to `dcm2niix` would include full output path to make it easier to
  discern in the logs what file it is working on ([#351][])
- With recent [datalad]() (>= 0.10), created DataLad dataset will use
  `--fake-dates` functionality of DataLad to not leak data conversion dates,
  which might be close to actual data acquisition/patient visit ([#352][])
- Support multi-echo EPI `_phase` data ([#373][] fixes [#368][])
- Log location of a bad .json file to ease troubleshooting ([#379][])
- Add basic pypi classifiers for the package ([#380][])

 Fixed
- Sorting `_scans.tsv` files lacking valid dates field should not cause a crash
  ([#337][])
- Multi-echo files detection based number of echos ([#339][])
- BIDS
  - Use `EchoTimes` from the associated multi-echo files if `EchoNumber` tag is
    missing ([#366][] fixes [#347][])
  - Tolerate empty ContentTime and/or ContentDate in DICOMs ([#372][]) and place
    "n/a" if value is missing ([#390][])
  - Do not crash and store original .json file is "JSON pretification" fails
    ([#342][])
- ReproIn heuristic
  - tollerate WIP prefix on Philips scanners ([#343][])
  - allow for use of `(...)` instead of `{...}` since `{}` are not allowed
    ([#343][])
  - Support pipolar fieldmaps by providing them with `_epi` not `_magnitude`.
    "Loose" BIDS `_key-value` pairs might come now after `_dir-` even if they
    came first before ([#358][] fixes [#357][])
- All heuristics saved under `.heudiconv/` under `heuristic.py` name, to avoid
  discrepancy during reconversion ([#354][] fixes [#353][])
- Do not crash (with TypeError) while trying to sort absent file list ([#360][])
- heudiconv requires nipype >= 1.0.0 ([#364][]) and blacklists `1.2.[12]` ([#375][])

* tag 'v0.6.0': (60 commits)
  Version boost to 0.6.0
  DOC: populate detailed changelog for 0.6.0 and tune up formatting in previous one
  Fix miscellaneous typos in ReproIn heuristic file.
  BF: fix check for the sbatch (SLURM) not being available
  ENH: make test-compare-two-versions take any two worktrees, and just show diff if results already known
  Update heudiconv/convert.py
  apply @mgxd 's suggestions, adding a warning and a timeout environment variable
  need str typecast
  Use empty string not None
  Empty acq_time results in empty cell not 'n/a'
  DOC: Clarify tarball session handling
  remove repetitive import statement
  respond to review - add explicit py2 check - change file saving strategy - use logger instead of print
  fix remaning py2 errors
  MNT: Add Python support metadata to package
  fix some python2/3 incompatibilities
  add return data (accidently removed return)
  make content unicode
  test that load_json provides filename if invalid
  explicitly name invalid json
  ...
yarikoptic added a commit that referenced this issue Dec 16, 2019
[0.6.0] - 2019-12-16

This is largely a bug fix.  Metadata and order of `_key-value` fields in BIDS
could change from the result of converting using previous versions, thus minor
version boost.
14 people contributed to this release -- thanks
[everyone](https://github.com/nipy/heudiconv/graphs/contributors)!

Enhancement

- Use [etelemetry](https://pypi.org/project/etelemetry) to inform about most
  recent available version of heudiconv. Please set `NO_ET` environment variable
  if you want to disable it ([#369][])
- BIDS:
  - `--bids` flag became an option. It can (optionally) accept `notop` value
    to avoid creation of top level files (`CHANGES`, `dataset_description.json`,
    etc) as a workaround during parallel execution to avoid race conditions etc.
    ([#344][])
  - Generate basic `.json` files with descriptions of the fields for
    `participants.tsv` and `_scans.tsv` files ([#376][])
  - Use `filelock` while writing top level files. Use
    `HEUDICONV_FILELOCK_TIMEOUT` environment to change the default timeout value
    ([#348][])
  - `_PDT2` was added as a suffix for multi-echo (really "multi-modal")
    sequences ([#345][])
- Calls to `dcm2niix` would include full output path to make it easier to
  discern in the logs what file it is working on ([#351][])
- With recent [datalad]() (>= 0.10), created DataLad dataset will use
  `--fake-dates` functionality of DataLad to not leak data conversion dates,
  which might be close to actual data acquisition/patient visit ([#352][])
- Support multi-echo EPI `_phase` data ([#373][] fixes [#368][])
- Log location of a bad .json file to ease troubleshooting ([#379][])
- Add basic pypi classifiers for the package ([#380][])

Fixed

- Sorting `_scans.tsv` files lacking valid dates field should not cause a crash
  ([#337][])
- Multi-echo files detection based number of echos ([#339][])
- BIDS
  - Use `EchoTimes` from the associated multi-echo files if `EchoNumber` tag is
    missing ([#366][] fixes [#347][])
  - Tolerate empty ContentTime and/or ContentDate in DICOMs ([#372][]) and place
    "n/a" if value is missing ([#390][])
  - Do not crash and store original .json file is "JSON pretification" fails
    ([#342][])
- ReproIn heuristic
  - tolerate WIP prefix on Philips scanners ([#343][])
  - allow for use of `(...)` instead of `{...}` since `{}` are not allowed
    ([#343][])
  - Support pipolar fieldmaps by providing them with `_epi` not `_magnitude`.
    "Loose" BIDS `_key-value` pairs might come now after `_dir-` even if they
    came first before ([#358][] fixes [#357][])
- All heuristics saved under `.heudiconv/` under `heuristic.py` name, to avoid
  discrepancy during reconversion ([#354][] fixes [#353][])
- Do not crash (with TypeError) while trying to sort absent file list ([#360][])
- heudiconv requires nipype >= 1.0.0 ([#364][]) and blacklists `1.2.[12]` ([#375][])

* tag 'v0.6.0':
  Boost perspective release date in changelog to today
  ENH(TST): Fix version to older pytest to ease backward compatibility testing
  RF: use tmpdir not tmp_path fixture
  FIX: minor typo in CHANGELOG.md