Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Move to z home with 3d touch[BUG] (bug summary) #1043

Closed
xingjl86 opened this issue Aug 21, 2023 · 5 comments
Closed

Move to z home with 3d touch[BUG] (bug summary) #1043

xingjl86 opened this issue Aug 21, 2023 · 5 comments
Labels
bug: False alarm? It is not a firmware bug or the bug cannot be confirmed.

Comments

@xingjl86
Copy link

Did you test with a precompiled firmware?

Yes, and the problem still exists.

Bug Description

When trying to Move to Z home, the 3d touch pin deployed in the first time and stow after touch the bed. It should deploy and touch the bed again for calculating, but it just shining without deploying and consider this position to be the second touch calculate height. So it would move to home about 5mm above the actual height. I think the time might be too short about the second time pin deploy. The pin could be deploy by the function "Deploy Z-Probe".
It might be the 3D touch was not working so good. But i think there shoube some delay here to be logical.

Bug Timeline

It might be the 3D touch was not

Expected behavior

Move to z home

Actual behavior

Move to the height just 5mm above the actual.

Steps to Reproduce

Move to z home

Version of Professional Firmware

2.1.3MRiscoC 20230809 official build & 20230522B

Printer model

Ender 3v2

Electronics

4.2.2

Add-ons

No response

Bed Leveling

ABL Bilinear mesh

Your Slicer

None

Host Software

None

Additional information & file uploads

No response

@xingjl86
Copy link
Author

I have tried to disable HS Mode, it's working now.

@mriscoc mriscoc added the bug: False alarm? It is not a firmware bug or the bug cannot be confirmed. label Aug 21, 2023
@mriscoc
Copy link
Owner

mriscoc commented Aug 21, 2023

With a compatible 3DTouch (3.1 version), in HS mode the pin is not stowed until finish the second probe. With HS mode disabled, the pin is stowed in each probing.

@xingjl86
Copy link
Author

So the problem might be the pin deployed but can not drop freely in the first probe.

@xingjl86
Copy link
Author

And Yes, it would be better to show False alarm and stop all the next steps.

@github-actions
Copy link

This issue has been automatically locked since there has not been any recent activity after it was closed. Please open a new issue for related bugs.

@github-actions github-actions bot locked and limited conversation to collaborators Oct 23, 2023